Gel electrode pH probe, 2 m cable, BNC connector

Regular price 99,90 €
Regular price Sale price 99,90 €
33,30 € × 3 with no fees

This gel-filled pH electrode has a plastic body, a 2 m cable, and a BNC connector.

It comes with everything needed to calibrate it on the day you first set it up: pH 7.0 and 4.0 buffers, distilled water, suction cups, and test tubes.

Ref. J6465100·pH measurement and regulation
Customer support 7 days a week by email
Delivery within 2 to 15 business days
100 % secure payment
Visa Mastercard American Express PayPalCartes Bancaires Apple Pay Shop Pay Bancontact EPS KlarnaMobilePay

The summary

  • What you receive: the electrode, its storage cap, 2 suction cups, 3 test tubes and 3 x 50 ml bottles.
  • What it provides: a continuous pH reading, transmitted to a controller via a BNC connector.
  • What to connect it to: any measuring or dosing device fitted with a BNC socket.
  • Its service life: approximately 24 months, with recalibration every 30 days.
  • Calibration: two-point, pH 7.0 then pH 4.0, with a rinse in distilled water in between.
  • Dispatch: packaged with protection, as the electrode is glass; can be grouped with your order.

Gel pH electrode with BNC connector, supplied with its calibration kit

A pH electrode is a glass membrane that produces a tiny voltage according to the acidity of the water surrounding it. Every reading shown on your controller, and every open or close command it sends, depends on this voltage. It is the most delicate component in a regulation system, and the only one that wears out, as its ageing begins from the day it is manufactured.

⚗️ A gel refill

A laboratory electrode contains a liquid electrolyte that requires regular topping up. This one is filled with gel: no electrolyte needs to be topped up or monitored, which considerably simplifies maintenance in a home setup. Its body is plastic rather than full glass, making it far less fragile when handling it over a tank or pond edge. The tip, however, remains glass: that is the membrane, and no pH electrode exists without one. Each electrode is tested individually and supplied with its own individual test report.

This detail spares you the most awkward step involved with a conventional electrode: opening a vent, topping up the filling solution, and closing it again without spilling any into the tank. Here, the probe is simply lifted out of the water, rinsed, and stored. Its large protective cap, filled with a storage solution, keeps the membrane moist between uses, because the tip must never dry out: a dried membrane loses its responsiveness, sometimes permanently.

Keep the cap and the socket out of the water

Never submerge the probe entirely: the upper part of its body and the cable connection must always remain out of the water, and ideally you should immerse it up to the top of the printed marking, without exceeding 2/3 of its length. Check the level regularly as well. A probe accidentally lifted clear of the water, or a level that drops significantly, will cause the controller to take incorrect readings and regulate accordingly, posing a real risk to your fish.

🔗 The BNC connector

Your cable is 2 m long and terminates in a BNC connector, a round bayonet fitting that locks with a quarter turn. This is a standard fitting, not a proprietary one: the probe can therefore be connected to any measuring or control instrument carrying this connector, regardless of brand, and in particular to the CO2 controller it is designed to accompany. Avoid running the cable alongside mains cables over long distances, as these interfere with the very low-level signal; also plan the position of the controller before fixing anything in place, by tracing the actual cable route along the unit.

Allowing for the reagents needed for subsequent recalibrations

The bottles supplied with the probe each contain 50 ml, and each calibration point requires approximately 10 ml of fresh solution. At the recommended rate of one calibration per month, the supplied buffer therefore lasts around 5 months. The pH 7 and pH 4 calibration kit then takes over with the same three bottles, distilled water included, and ensures you are never held up by a lack of buffer solution.

🎯 Two-point calibration

Once connected to its controller, the probe is calibrated for the first time on the day it is unpacked, before being installed in the tank. Pour approximately 10 ml of pH 7.0 buffer into a test tube, submerge the tip, wait for the reading to stabilise, then confirm. Rinse with distilled water and repeat with the pH 4.0 buffer, then confirm. The order matters: always pH 7 first, then pH 4, never the other way round, because the first point sets the zero of the probe and the second establishes the slope of its calibration curve. Discard the remaining buffer solution afterwards, and repeat the procedure every 30 days, 60 at most, as the probe ages continuously and each calibration compensates for this drift.

🗓️ A part that can be replaced

Allow around 24 months. Your electrode ages chemically from the moment it is manufactured, and that ageing shows itself before it becomes a problem: the reading takes longer and longer to stabilise in the buffer solution, then calibration can no longer reach a correct value. At that point, replace it, a worn probe controlling gas injection puts your fish at risk. Note the date you put it into service on the unit or in a logbook: it is the only way to know where you stand 2 years later, as an electrode carries no usage counter. See also the article on pH regulation.

A controller that displays the probe voltage lets you track this wear in figures. A new probe delivers approximately 0 mV in pH 7 buffer, and its voltage varies by approximately 59 mV per pH unit, giving roughly 177 mV in pH 4 buffer. As it ages, two things change: the voltage at pH 7 moves away from zero, for example to 28 mV, and the variation per pH unit decreases, for example to 46 mV. The JBL regulation controller accepts a probe up to 115 mV offset at pH 7 and down to 35 mV per unit, and rejects it beyond those limits at the end of calibration.

🧫 Placement and maintenance

Fix your probe using the two suction cups provided, positioned vertically or at a slight angle, tip pointing downwards, in a well-circulated and low-light area. Orientation matters: lying horizontal, the probe will eventually trap an air bubble against its membrane, causing the displayed value to become unstable. A shaded position slows the growth of algae that would otherwise build up on the glass and distort the reading. If a deposit forms despite this, clean the tip with a soft cloth, dabbing gently, never rubbing, then recalibrate immediately afterwards. When out of the water, always replace the protective storage cap, and store a probe that will not be used for several weeks in an appropriate storage solution rather than in plain water.

In aquaponics, continuous measurement really comes into its own, because the pH of a system where nitrification is active falls slowly, week by week, as alkalinity is consumed. A probe installed in the sump or in the fish tank reveals this trend well before a weekly test would flag it, and indicates the moment when the buffer needs to be replenished. Position it away from the water inlet of the grow beds and from any corrective additions, so that it measures the system water rather than an input that has not yet mixed in.

Technical specifications

The electrode

Filling
GelNothing to top up, unlike a liquid-electrolyte electrode.
Body
PlasticLess fragile than an all-glass body.
Control
Tested one by oneSupplied with its individual test report.
Storage
Cap filled with solutionThe tip must never dry out.

Connection

Connector
BNC
Cable length
2 mKeep it away from electrical cables along its entire length.

Service life and calibration

Replacement
Approximately 24 months
Calibration
Every 30 days60 days at most, always pH 7 first, then pH 4.

To budget for separately

Subsequent recalibrations
pH 7 and pH 4 solutions

2 further specifications are available in the detailed view.

In the box

  • 1 gel-filled pH electrode, 2 m cable and BNC connector
  • 1 storage cap
  • 2 fixing suckers
  • 3 graduated test tubes
  • 1 pH 7.0 buffer solution bottle, 50 ml
  • 1 bottle of pH 4.0 buffer solution, 50 ml
  • 1 bottle of distilled water, 50 ml

Electrode type, cable length, connector, kit contents, individual inspection, average service life, voltages, and calibration schedule taken on 07/10/2026 from the data sheet and instruction manual of manufacturer JBL, reference 6465100.

Estimate your
delivery time

This probe has a glass tip and is supplied protected in its case. It is shipped together with the rest of your order, the postage for which is calculated at checkout according to your destination.

Frequently asked questions

10 questions

6 key questions, 10 in the detailed view

You may also like

Let us talk about your project

A question about this product or your setup? Our team will answer and advise you.

Interest-free instalment payments

Offered depending on the cart amount, at checkout.

Delivery in 2 to 15 working days

Depending on the products and shipping sites. Estimate by destination in the estimator on this page.

After-sales service 7 days a week by email or chat

Our team answers all your questions.

Shop responsibly

Become part of the change.