CO2, pH, and temperature controller
This touchscreen controller reads pH and water temperature continuously, and controls the JBL ProFlora CO2 Valve solenoid valve according to the target value — to be included with your gas installation.
You enter your KH, and the controller calculates the target pH automatically. The temperature probe and 12 V power supply are included.
The summary
- What you receive: the control unit, its temperature probe, the wall rail, the solenoid valve cable, the 12 V power supply, and a test tube holder.
- What it does: it compares the measured pH to the target pH and opens or closes the gas supply all day long, without any input from you.
- What it controls: the JBL ProFlora CO2 Valve, based on readings from a BNC-connector pH probe.
- The setting that matters: the carbonate hardness of your water, entered once and checked again each month.
- When to connect it: once the pH in your tank has stabilised — not on a fresh fill.
- Dispatch: standard parcel; the unit is light but bulky and can be combined with your order.
Touch-screen controller that reads pH and temperature and operates the CO2 solenoid valve
Injecting CO2 into a planted tank promotes plant growth and lowers the pH. An excess of gas makes the water acidic enough to cause stress to the fish, which is why this controller regulates the injection: it measures pH continuously, compares it to your target value, and operates the solenoid valve to allow or cut the gas flow.
The difference from a manually adjusted injection is clear throughout the day: a bubble counter delivers the same flow rate at noon and at midnight, whereas plants consume CO₂ during the day and not at night. A controller follows the actual demand of the tank hour by hour, and shuts off automatically when photosynthesis stops. Start by setting your bubble counter to around 10 bubbles per minute per 100 L, then increase to 20–25 if the target is not reached after a day: the correct flow rate is the one that causes the valve to cut off 3 to 6 times per day.
🧮 KH sets the target value
pH, dissolved CO2, and carbonate hardness are linked by a fixed relationship. That is why the unit asks for your KH rather than a pH: using its Auto pH function, it calculates from that single value the set point that delivers approximately 22.5 mg/L of CO2, the middle of the range that is useful for plants and safe for fish. Factory-set to a KH of 8 °dKH, it targets a pH of 7.03. Measure your KH before first use with a carbonate hardness test kit, and repeat the measurement once a month, as adding osmosis water, changing the substrate, or introducing new rocks will alter the KH, and a set point calculated from an outdated reading will be incorrect.
Choosing a setting that is safe for the fish
Never set a pH target arbitrarily. With a high KH, a target below pH 7.00 requires so much CO2 that it puts your fish at risk: if you want a lower pH, reduce the KH first. When you enter a target manually, the unit calculates the KH that would correspond to it and alerts you if it is more than one degree below your actual KH. If in doubt, let the Auto pH function choose for you.
🖥️ What the screen shows
The colour touchscreen shows at a glance the measured pH and the target pH, the water temperature, the solenoid valve status, the probe voltage in millivolts, measurement accuracy, and the time remaining until the next calibration. A difference between the two pH values means the gas is actively working; a gap that never closes indicates an empty cylinder or a probe that needs recalibrating. Alarms can be set independently for pH and temperature, as a flashing alert alone or with an audible signal: from the factory, they trigger at 1.00 pH unit from the target and outside the 20–30 °C range, and bringing the pH alarm down to 0.50 gives you earlier warning of an empty cylinder or a flow rate issue.
Connect a new probe from the moment you set up
The controller is supplied without a pH probe, so you start with a fresh electrode rather than one that has been sitting in stock. The gel electrode pH probe plugs into its BNC socket and comes with pH 7 and pH 4 buffers, distilled water, and test tubes. Keep the calibration kit in reserve and you will also have everything needed for recalibration in the months ahead.
Hysteresis
This is the margin around the set point, adjustable from 0.1 to 0.5 pH. At 0.1, the valve does not open at every hundredth.
Alarms
They flag a pH that has drifted from the set point or a temperature outside the limits you define.
Low voltage
The unit, its probes and the solenoid valve all run on 12 V, a sensible safety measure near water.
Lock
A 4-digit code locks the screen, useful when children are around the tank.
🔁 Electrode placement
The reading is only valid if the electrode is immersed in water that is representative of the tank. Never place it above your diffuser, as the bubbles create a highly acidic zone right around the glass: the unit reads a pH already at the target whilst the rest of the tank is not, and it cuts the gas off too early. Position it upstream of the injection point, in a well-circulated, dark area, for example near the filter intake strainer, using the suction cups supplied with the probe. Submerge it no more than 2/3 of its length, cap and cable out of the water, and keep its cable away from electrical cables. The 2 suction cups supplied with the controller are used to hold the temperature probe, which can be placed anywhere in the tank.
🎯 Calibration and its reminder
On first switch-on, the unit prompts you to select a language, then requires a two-point calibration before any other setting can be adjusted. Both probes, pH and temperature, are immersed together in each solution: first the pH 7.00 buffer, then the pH 4.00 buffer, never the other way round. The unit allows up to one and a half minutes per buffer for the signal to stabilise. The calibration reminder is factory-set to 30 days and can be extended to 45 or 60 days, though the latter is not recommended. Once the interval has elapsed, the unit continues to regulate, but the alarm will only clear after a fresh calibration. The messages DELTAV, OFFSET and UNSTAB indicate, respectively, a slope that is too low, an offset zero and an unstable signal, usually a probe that needs cleaning or replacing.
🚨 The new tank trap
A technical substrate releases acidity during its first few weeks. If you connect the controller straight away, it reads a pH already below the set point and either never opens the gas valve, or opens it in fits and starts. Allow the tank to stabilise, carry out your water changes, and start the regulation once the pH no longer shifts from one day to the next. The first weeks of a new setup are for biological cycling, which a gas injection will not speed up. The same caution applies after a large water change or a filter clean: wait 1 or 2 days for the reading to return to its normal level before relying on the regulation.
🌿 pH in aquaponics
In a system where fish, bacteria, and plants share the same water, pH is the result of a constant compromise: above 7, iron and manganese become less available to plants, while below that level, the biofilter bacteria slow down. A continuous-monitoring controller reveals the gradual drift that manual testing misses. The topic is covered in depth in regulating the pH of an aquaponic system, and can be verified by hand with a pocket tester once a week. A fish tank connected to growing beds will also see its pH drop naturally over the weeks, as nitrification consumes alkalinity. The controller reveals this drop but cannot correct it: if the set point is reached without the gas valve ever opening, your water is acidifying on its own and the KH is falling.
🪸 The calcium reactor
The unit also works in saltwater, on a calcium reactor. This reactor dissolves the limestone of a grow medium, coral rubble, for example, to restore to the aquarium the carbonate hardness that its inhabitants consume, and for this it requires a pH of around 6.5, maintained continuously by CO2 injection. Fit the probe in the designated port on the reactor, or in the outflow, set the target to 6.5 and connect the solenoid valve to the CO2 supply feeding the reactor. Natural seawater contains, as a reference, between 6 and 9 °dKH depending on the region.
📦 What's in the box
You receive the touch-screen unit, its digital temperature probe and 2 suction cups, the wall-mounting rail with 2 screws and 2 wall plugs, the solenoid valve connection cable, the 12 V power supply and a test tube rack for calibration. The pH probe and the solenoid valve are ordered separately, which means you can keep the controller when the electrode reaches the end of its life. The unit controls the JBL ProFlora CO2 Valve, or any CO2 system fitted with one, and this is what you need to plan for on your cylinder.
First fix the rail horizontally on the wall, close to the tank, using the two screws supplied, then hang the unit from the top and click it into place with a gentle push; it releases by sliding it sideways. Unroll the solenoid valve cable before drilling, as its length determines the distance between the display and the bottle. The unit is for indoor use only, in a dry location protected from frost, and its settings are retained in the event of a power cut.
Technical specifications
What it measures and controls
- Parameters read
- pH and water temperature
- Outlet
- Électrovanne JBL ProFlora CO2 ValveThe unit doesn't produce gas — it allows or cuts the flow.
Settings
- Set point
- Auto pH, calculated from KHFor approximately 22,5 mg/L of CO2. Re-enter after any change in KH.
- Hysteresis
- 0.1 to 0.5 pHFactory setting of 0.1: the valve closes 0.1 below the set point and reopens 0.1 above it.
Power supply and mounting
- Feed
- Mains adaptor 12 V included
- Installation
- Wall rail, 2 screws and 2 wall plugsIndoor use only, keep dry and frost-free.
Safety
- pH alarm
- ±1.00 pH from the factoryAdjustable from 0.10 to 2.00; 0.50 gives earlier warning of an empty bottle.
- Temperature alarm
- 20 to 30 °C factory settingIndependently adjustable thresholds, with flashing only or with an audible alert.
Calibration and weight
- Calibration reminder
- Every 30 days45 or 60 days are possible, though 60 is not recommended.
- Weight
- 0.68 kg
To budget for separately
- pH probe
- BNC connector electrode
- Solenoid valve
- JBL ProFlora CO2 ValveThe only solenoid valve the unit controls.
- CO2 source
- Bottle, regulator and diffuser
- Calibration solutions
- pH 7 and pH 4 buffer solutions
6 further specifications are available in the detailed view.
In the box
- 1 touchscreen control unit
- 1 digital temperature probe with 2 suction cups
- 1 wall mounting rail, 2 screws and 2 wall plugs
- 1 solenoid valve connection cable
- 1 12 V power supply
- 1 test tube rack for calibration
Box contents, weight, power supply, factory settings, alarms, hysteresis, calibration reminder, and Auto pH function recorded on 07/10/2026 from the JBL manufacturer's product sheet and instructions, reference 6465000.
Estimate your
delivery time
Your estimate
It covers preparing your order and then the transit time quoted by the carrier, counted in working days.
It is not a guaranteed delivery date: public holidays, peak periods, customs or a carrier delay can extend it. The exact amount, in your currency, is worked out in the cart once your address is entered.
This controller ships as a standard parcel. It is light but its packaging is bulky, and it groups easily with a probe and a CO2 kit. The exact amount is calculated at checkout based on your destination.
Frequently asked questions
12 questions
6 key questions, 12 in the detailed view
You may also like
Let us talk about your project
A question about this product or your setup? Our team will answer and advise you.
Interest-free instalment payments
Offered depending on the cart amount, at checkout.
Delivery in 2 to 15 working days
Depending on the products and shipping sites. Estimate by destination in the estimator on this page.
After-sales service 7 days a week by email or chat
Our team answers all your questions.
Shop responsibly
Become part of the change.