Waterproof EC and TDS conductivity meter with replaceable probe
This waterproof tester displays conductivity to two decimal places, TDS and temperature on a single screen, from 0 to 20 mS/cm. It self-calibrates at one point on a 12.88 mS/cm solution, and its probe can be replaced when it wears out, so you don't have to buy a new device.
The summary
- What you receive: the tester and its cap, a calibration sachet and 4 batteries.
- What it measures: conductivity to the hundredth, TDS and temperature, all on one screen.
- Calibration: automatic, single-point, using a 12.88 mS/cm solution.
- The probe: replaceable, so you can keep the device when the electrode wears out.
- In aquaponics: precise tracking of how conductivity changes, week after week.
- Battery life: around 100 hours on 4 LR44 batteries, automatic switch-off after 8 minutes.
3-in-1 pocket tester for monitoring a nutrient solution or rearing water
The EC60 is a waterproof pocket tester that shows the water's electrical conductivity, its total dissolved solids content (TDS) and its temperature on the same screen. You remove the cap, dip the probe into the solution and the reading appears, already temperature-compensated, to a hundredth of a millisiemens per centimetre. The probe unscrews and can be replaced when it wears out, so the meter itself will serve you well beyond the life of a single electrode.
📟 Three readings on one screen
Conductivity
It displays from 0.00 to 20.00 mS/cm, in steps of 0.01 mS/cm, which makes the smallest variations visible.
Dissolved solids
TDS is read from 0.00 to 10.00 ppt, calculated from conductivity using an adjustable factor.
Temperature
It displays from 0.0 to 60.0 °C on the secondary screen, in degrees Celsius or Fahrenheit.
Frozen reading
Pressing and holding SET/HOLD freezes the value, which you then read off out of the water.
Accuracy reaches ±2% of full scale for conductivity and TDS, and ±0.5 °C for temperature. Automatic compensation brings every reading back to a reference temperature, because the conductivity of the same solution rises with heat. Its coefficient, denoted β, can be set from 0.0 to 2.4% per degree: you can therefore adapt it to the nature of your solution, and your summer readings remain comparable with those taken in winter. The TDS conversion factor is adjusted in the same way, in the configuration menu.
⚙️ Automatic calibration
Calibration is a single-point procedure with no manual adjustment. Hold the ON/OFF/CAL button until the secondary display shows CAL, then place the probe in a 12.88 mS/cm calibration solution: the meter recognises the value, shows OK for one second and returns to measuring mode on its own. TDS does not need separate calibration, as it is derived from conductivity. Frequent calibration improves accuracy, and it becomes necessary after changing the probe, after measuring in an aggressive chemical, and whenever you need high accuracy.
Measure the pH on the same round
Conductivity shows how much dissolved salt is present, but not whether the plants can absorb it: that is down to pH. The AMTRA electronic pH tester goes into the same sample cup as the EC60, so you get both readings in a minute. That way you record the conductivity and pH pair every week, a pair of values that explains many deficiencies before they show on the foliage.
Rinse the probe after each measurement
After use, always switch the tester off, rinse the probe with water, then put its protective cap back on. Salts from a nutrient solution that dry on the electrodes skew later readings. Before screwing the battery compartment or the probe ring back on, check that each seal is in place, as it is what guarantees watertightness.
🌱 In aquaponics
In an aquaponic system, the nutrients come from the fish feed, so conductivity stays lower than in hydroponics and its exact value depends on your starting water. What tells you something is its trend from one week to the next: a steady rise points to salts that the plants are not absorbing, while a prolonged fall points to a system that is becoming depleted. The EC60's resolution to the hundredth makes these shifts readable well before they become significant. Record the value on a fixed day, together with the temperature shown by the meter, and the guide to plant deficiencies in aquaponics will help you interpret any drift.
Measure the conductivity as soon as the system is filled, to give yourself a baseline specific to your water. The cycling that follows lasts 4 to 6 weeks with fish, or 10 days to 3 weeks without fish, and it is complete when ammonia and nitrite have fallen back to 0.5 mg/L or less while nitrates become measurable, as confirmed by the nitrite drop test. During this period, measurements are taken every day, then once a week once the system is balanced. The TDS shown alongside is mainly used to compare your readings with values expressed in ppm or ppt, and it only stays comparable from one week to the next if you keep the same conversion factor in the menu.
In decoupled aquaponics, where a separate growing loop receives the fish water without ever returning it to the pond, the EC60 is also used to dose the extra fertiliser given to the plants: you add the fertiliser in small amounts, take a reading, then stop at the target value for your crops. The same approach applies in hydroponics, where the solution is prepared and corrected with a conductivity meter. Rinse the probe thoroughly between the fertiliser solution and the fish water, and calibrate more often if you regularly switch from lightly loaded water to a concentrated solution, since frequent calibration improves the accuracy of the reading.
🔧 Replaceable probe and lifespan
When the probe wears out, you remove the cap, unscrew the plastic ring at the top of the probe and replace the MI59P electrode with a new one, before recalibrating. The tester runs for about 100 hours on 4 x 1.5 V LR44 batteries and switches itself off after 8 minutes of inactivity. When the batteries run low, a symbol warns you, then the device shuts itself off before the low voltage can skew a reading. The casing measures 200 mm long by 38 mm in diameter and weighs 100 g; it is guaranteed for 2 years, and the probe for 6 months. The shop's other electronic testers cover pH and simpler needs.
Technical specifications
Measurements
- Conductivity
- 0.00 to 20.00 mS/cmResolution of 0.01 mS/cm
- Dissolved solids
- 0.00 to 10.00 pptAdjustable conversion factor
- Temperature
- 0.0 to 60.0 °C0.1 °C resolution, in °C or °F
- Accuracy
- ±2% of full scale±0.5 °C on the temperature
- Compensation
- Automatic, β from 0.0 to 2.4 %/°CCoefficient adjustable to suit the solution
- Calibration
- Automatic, 1 pointIn a 12.88 mS/cm solution
The device
- Probe
- Replaceable, MI59PUnscrews by the top ring
- Housing
- Watertight, screw-fitted seals
- Batteries
- 4 x 1.5 V, type LR44Around 100 hours of use
- Automatic shut-off
- After 8 minutesSafety cut-off if the batteries run low
- Dimensions
- 200 mm, Ø 38 mm
- Weight
- 100 g
- Warranty
- 2 years, probe 6 months
- Reference
- Milwaukee EC60
In use
- Environment
- 0 to 50 °CUp to 100% relative humidity
- Frozen reading
- HOLD function
To allow for in addition
- Calibration solution
- Sachet 12,880 µS/cmFor the following calibrations
- Measuring pH
- 1 pH testerConductivity says nothing about acidity
10 further specifications are available in the detailed view.
In the box
- 1 Milwaukee EC60 tester with protective cap
- 1 sachet of 12,880 µS/cm calibration solution, 20 ml
- 4 1.5 V batteries
Manufacturer's values (Milwaukee EC59 and EC60 instructions, tester data sheet). Box contents based on the manufacturer's photograph.
Manufacturer and product safety
- Manufacturer
- Milwaukee Instruments
- Website
- www.milwaukeeinst.com
Information provided under Regulation (EU) 2023/988 on general product safety.
The tenth or the hundredth?
Three ways to read EC in the field: to the tenth with a screwdriver, to the hundredth automatically, or to the hundredth with TDS and a spare probe.
| Range | Resolution | Calibration | Temperature displayed | TDS display | Model | Price | |
|---|---|---|---|---|---|---|---|
| Pocket conductivity meter for nutrient solution, 0 to 20 mS/cmYour choice | 0 to 19.9 mS/cm | 0.1 mS/cm | Manual, with a screwdriver | No | No | Milwaukee CD611 | 26,90 € |
| Waterproof conductivity meter, 0.01 resolution, 0 to 20 mS/cmYour choice | 0 to 20.00 mS/cm | 0.01 mS/cm | Automatic, 1 point | Yes | No | Hanna DiST 4 | 59,90 € |
| Recommended Waterproof EC and TDS conductivity meterYour choice | 0 to 20.00 mS/cm | 0.01 mS/cm | Automatic, 1 point | Yes | Yes | Milwaukee EC60 | 64,90 € |
Ranges, resolutions, calibration and displays taken from the Milwaukee and Hanna manuals and data sheets for the three testers.
Buying guide
Two questions to help you choose your tester
Documents & manuals
User guide for the EC59 and EC60 testers
Measurement, setting the TDS factor and the β coefficient, calibration, replacing the probe and the batteries, in French among other languages.
Document not showing? Some publishers block display inside a frame, so open it in a tab.
Estimate your
delivery time
Your estimate
It covers preparing your order and then the transit time quoted by the carrier, counted in working days.
It is not a guaranteed delivery date: public holidays, peak periods, customs or a carrier delay can extend it. The exact amount, in your currency, is worked out in the cart once your address is entered.
The tester is sent in its original box, as a small parcel, from a distributor's warehouse in France. The exact shipping cost is shown in your basket.
Frequently asked questions
8 questions
6 key questions, 8 in the detailed view
You may also like
Let us talk about your project
A question about this product or your setup? Our team will answer and advise you.
Interest-free instalment payments
Offered depending on the cart amount, at checkout.
Delivery in 2 to 15 working days
Depending on the products and shipping sites. Estimate by destination in the estimator on this page.
After-sales service 7 days a week by email or chat
Our team answers all your questions.
Shop responsibly
Become part of the change.