Waterproof conductivity meter, 0.01 resolution, 0 to 20 mS/cm
This waterproof tester measures conductivity to the hundredth, from 0 to 20 mS/cm, and shows the water temperature on the same screen. Its graphite electrode resists oxidation, and calibration is automatic using the solution sachets supplied.
The summary
- What you receive: the tester, its CR2032 battery, 4 sachets of calibration solution at 12.88 mS/cm and a carry case.
- What it measures: conductivity from 0.00 to 20.00 mS/cm, and temperature from 0 to 50 °C.
- The electrode: graphite rather than metal pins, which oxidises less and polarises less.
- Calibration: automatic, at a single point, in the 12.88 mS/cm solution.
- In aquaponics: a reading to the hundredth that makes small variations visible in lightly loaded water.
- Battery life: around 250 hours on a button cell, with an adjustable auto-off.
Pocket EC tester reading to the hundredth, graphite electrode and temperature reading
The DiST 4 HI98304 is a waterproof pocket conductivity meter that displays the electrical conductivity of water to a hundredth of a millisiemens per centimetre, from 0.00 to 20.00 mS/cm, along with the temperature at the same time. It is used to dose a nutrient solution, to check the mineral content of irrigation water or to monitor how a fish tank is changing. Because its resolution goes down to 0.01 mS/cm, it shows up small differences in low-mineral water, where a tester reading to a tenth gives the same figure from one week to the next. It measures 160 x 40 x 17 mm and weighs 75 g with its battery.
🧪 A graphite electrode
Most entry-level conductivity meters measure with two stainless steel pins. The DiST 4 uses an amperometric-type graphite electrode, which resists oxidation and limits polarisation, the phenomenon that makes the reading drift when ions build up on the surface of the sensor. The result is a measurement that stays more stable over time, especially in nutrient solutions heavily loaded with salts. A temperature sensor mounted exposed next to the electrode tracks the water quickly, and automatic compensation applies from 0 to 50 °C to bring each reading back to a reference temperature.
📏 Automatic calibration
Calibration is done at a single point, in a standard solution of 12.88 mS/cm. You pour the contents of a sachet into a small cup, dip the probe tip in, start the calibration with one press of the button and the device recognises the value on its own, with no screwdriver or manual adjustment. The box contains 4 sachets, enough to calibrate several times before you need to buy more. The stated accuracy is ±2% of full scale. The temperature is displayed in degrees Celsius or Fahrenheit, depending on a setting accessible in the battery compartment.
A dual display
Conductivity and temperature are displayed together, with a stability indicator and a calibration indicator.
Two buttons
One turns the device on, the other starts calibration, with no menu to navigate.
Adjustable switch-off
The tester switches off after 8 or 60 minutes, or stays on for a long series of measurements.
Battery charge
The level is displayed at switch-on, and a warning appears below 10% remaining charge.
Dosing a three-part fertiliser with a conductivity meter
With a mineral fertiliser that you mix yourself, conductivity tells you whether the prepared solution reaches the target concentration, and it is what guides you from one renewal to the next. The three-part hydroponics fertiliser kit is dosed as follows: you add the three parts, mix, then read the value on the DiST 4 before correcting. Reading to the hundredth lets you fine-tune the dose without going back through repeated dosing.
A calibration solution can only be used once
A calibration solution that has had the tip of the tester in it can no longer be relied on. Throw it away after calibrating and open a fresh sachet each time, otherwise the meter calibrates on a faulty value and all subsequent readings are wrong too. Rinse the tip with water before dipping it into the calibration solution, so as not to carry over the salts from the previous reading.
⚡ What conductivity tells you
Electrical conductivity reflects the amount of ions dissolved in the water. The more mineral salts a solution contains, such as the nitrates, potassium or calcium supplied by a fertiliser, the better it conducts current between the faces of the electrode, and the higher the displayed value rises. The DiST 4 expresses it in millisiemens per centimetre, where 1 mS/cm equals 1,000 µS/cm, the unit used in some tables for very soft water. The measurement does not tell you which elements are present or in what proportions, so an unbalanced solution can still show the right value. It does, however, tell you within seconds the overall concentration, which is enough to prepare a solution, check that an addition has been made or spot a drift. Since conductivity varies with temperature, automatic compensation makes two readings taken in the morning and in the afternoon comparable.
In hydroponics, the reading comes into its own between two changes of the solution. If the value rises while the level in the reservoir drops, the plants have absorbed more water than salts, and topping up with clean water brings the concentration back down; if it falls markedly, the roots have taken up nutrients faster than water, and the solution needs a top-up of fertiliser. Measuring tap water once, on its own, also gives you the starting conductivity of your water, which adds to that of the fertiliser: hard water already shows a value that you will find again in every solution you prepare. For the Kratky method as for a tower or an ebb-and-flow table, this regular check avoids changing the solution too early or too late.
🌱 Low-load water in aquaponics
In aquaponics, conductivity stays much lower than in hydroponics, since the nutrients come from the fish feed and the bacteria that break it down. The figure that matters is above all its trend: a value that rises week after week points to salts the plants are not absorbing, while a value that falls points to a system that is becoming depleted. This is where the hundredth-place resolution proves its worth, as it shows a trend that a tenths display would hide. Record the value on a fixed day, together with the pH, and compare it with the nitrogen cycle to understand where the variations come from. The guide to deficiencies in aquaponics then helps you interpret yellowing foliage.
In a coupled system, where the same water circulates between the fish tank and the grow beds, always measure at the same point, for example in the sump, and at the same time of day. Daily checks are worthwhile during start-up, then a weekly reading is enough once the system has settled, covering pH, ammonium, nitrite and nitrate. Nitrates above 150 mg/L indicate a system with too few plants for its fish load, and conductivity rises at the same time: the nitrate drop test then confirms what the trend is telling you. In decoupled aquaponics, where a separate growing loop receives water from the fish without ever returning it to the tank, the DiST 4 becomes the dosing tool it is in hydroponics and tells you how much to top up the plant solution.
📝 One measurement, one record
The measurement itself takes just a few steps. Remove the cap, rinse the tip with clean water, then dip it into the sample and stir gently to dislodge any air bubble clinging to the electrode. Wait for the reading to stabilise, which the indicator on the screen will show you, then record the conductivity and the temperature in a notebook or a spreadsheet. The tester does not alter the water: you can dip its tip into the fish tank, provided you rinse it between a nutrient solution and the system water so that no salts are carried from one to the other. Rinse again after measuring, let it dry and put the cap back on. A check calibration in a fresh sachet, whenever a reading looks inconsistent, keeps the measurement reliable over time.
Technical specifications
Measurement and accuracy
- Measuring range
- 0.00 to 20.00 mS/cm
- Resolution
- 0.01 mS/cm
- Accuracy
- ±2% of full scale
- Temperature
- 0 to 50 °CTo a tenth of a degree, ±0.5 °C
- Compensation
- Automatic, from 0 to 50 °C
- Reference
- Hanna HI98304, DiST 4
Electrode and calibration
- Electrode
- Graphite, amperometric typeLess prone to oxidation than steel pins
- Calibration
- Automatic, 1 pointIn a calibration solution at 12.88 mS/cm
- Indicators
- Stability, calibration, battery
- Housing
- Waterproof, two buttons
Power supply and size
- Battery
- 1 CR2032, 3 VAround 250 hours of continuous use
- Automatic switch-off
- 8 or 60 min, or switched off
- Dimensions
- 160 x 40 x 17 mm
- Weight
- 75 g with the battery
To allow for in addition
- Calibration solution
- 12.88 mS/cmOnce the 4 sachets in the box have been used
- Measuring pH
- 1 pH tester
8 further specifications are available in the detailed view.
In the box
- 1 DiST 4 HI98304 tester with protective cap
- 1 CR2032 battery
- 4 sachets of 12.88 mS/cm calibration solution
- 1 protective case
- 1 quality certificate and 1 instruction manual
Manufacturer's values (Hanna HI98304 technical sheet). Weight of 68 g without battery and 75 g with.
Manufacturer and product safety
- Manufacturer
- Hanna Instruments
- Website
- www.hannainstruments.fr
Information provided under Regulation (EU) 2023/988 on general product safety.
The tenth or the hundredth?
All three compensate for the effect of temperature. They differ in reading resolution, calibration and what the screen displays in addition to the EC.
| Range | Resolution | Calibration | Temperature displayed | TDS display | Model | Price | |
|---|---|---|---|---|---|---|---|
| Pocket conductivity meter for nutrient solution, 0 to 20 mS/cmYour choice | 0 to 19.9 mS/cm | 0.1 mS/cm | Manual, with a screwdriver | No | No | Milwaukee CD611 | 26,90 € |
| Recommended Waterproof conductivity meter, 0.01 resolution, 0 to 20 mS/cmYour choice | 0 to 20.00 mS/cm | 0.01 mS/cm | Automatic, 1 point | Yes | No | Hanna DiST 4 | 59,90 € |
| Waterproof EC and TDS conductivity meterYour choice | 0 to 20.00 mS/cm | 0.01 mS/cm | Automatic, 1 point | Yes | Yes | Milwaukee EC60 | 64,90 € |
Ranges, resolutions, calibration and displays taken from the data sheets and manuals of the two manufacturers.
Buying guide
Two questions to find the right conductivity meter
Estimate your
delivery time
Your estimate
It covers preparing your order and then the transit time quoted by the carrier, counted in working days.
It is not a guaranteed delivery date: public holidays, peak periods, customs or a carrier delay can extend it. The exact amount, in your currency, is worked out in the cart once your address is entered.
The tester is sent in its original box, as a small parcel, from a distributor's warehouse in France. The exact shipping cost is shown in your basket.
Frequently asked questions
8 questions
6 key questions, 8 in the detailed view
You may also like
Let us talk about your project
A question about this product or your setup? Our team will answer and advise you.
Interest-free instalment payments
Offered depending on the cart amount, at checkout.
Delivery in 2 to 15 working days
Depending on the products and shipping sites. Estimate by destination in the estimator on this page.
After-sales service 7 days a week by email or chat
Our team answers all your questions.
Shop responsibly
Become part of the change.