JBL ProFlora CO2 pH Sensor Set pH probe, BNC gel electrode

Regular price 99,90 €
Regular price Sale price 99,90 €
33,30 € × 3 with no fees

This gel-filled pH electrode has a plastic body, a 2 m cable, and a BNC connector.

It comes with everything needed to calibrate it on the day you first set it up: pH 7.0 and 4.0 buffers, distilled water, suction cups, and test tubes.

Ref. J6465100·Aquarium CO2
Customer support 7 days a week by email
Delivery within 2 to 15 business days
100 % secure payment
Visa Mastercard American Express PayPalCartes Bancaires Apple Pay Shop Pay Bancontact EPS KlarnaMobilePay

The summary

  • What you receive: the electrode, its cap, 2 suction cups, 3 test tubes and 3 50 ml bottles.
  • What it offers: continuous pH measurement, sent to a controller through a BNC connector.
  • What to connect it to: any measuring or control device fitted with a BNC connector.
  • Its lifespan: about 24 months, with a recalibration every 30 days.
  • Calibration: two points, pH 7.0 then pH 4.0, with a rinse in distilled water between the two.
  • Shipping: protected, tracked parcel, as the electrode tip is made of glass, with costs calculated at checkout.

Gel pH electrode with BNC connector, supplied with its calibration kit

The JBL ProFlora CO2 pH Sensor Set pH probe is a gel electrode with a plastic body, designed to measure pH continuously and send this signal to a controller through a 2 m cable ending in a BNC plug. It connects to any device fitted with this connector, lasts about 24 months and should be recalibrated every 30 days.

A pH electrode has a glass membrane at its tip that produces a tiny voltage depending on the acidity of the water around it. Every value shown by your controller, and every command to switch on or off that it sends, depends on this voltage. It is the most fragile part of a control system, and the only one that wears out, since its ageing begins on the very day it is made.

⚗️ A gel refill

A laboratory electrode contains a liquid electrolyte that has to be topped up regularly. This one is filled with gel: no electrolyte needs topping up or monitoring, which makes its maintenance much simpler on a domestic installation. Its body is made of plastic rather than all glass, which also makes it much less fragile when you handle it over a tank or a pond edge. The tip remains glass, since it carries the pH-sensitive membrane. Each electrode is tested individually and supplied with its individual test report.

This detail spares you the most fiddly part of a conventional electrode: opening a vent, topping up a liquid and closing it again without spilling any into the tank. Here, the probe is simply lifted out of the water, rinsed and stored. Its large protective cap, filled with a storage solution, keeps the membrane moist between uses, because the tip must never dry out: a dried-out membrane loses its responsiveness, sometimes permanently.

Keep the cap and the socket out of the water

Never immerse the entire probe: the top of its body and the cable connection must always stay out of the water, and ideally you should immerse it up to the top of the lettering, without exceeding 2/3 of its length. Check the water level regularly as well. A probe that has come out of the water by accident, or a level that drops sharply, makes the controller measure incorrectly, and it then regulates accordingly, with a real risk to your fish.

🔗 The BNC connector

Your cable is 2 m long and ends in a BNC plug, a round bayonet connector that locks with a quarter turn. This connector is an instrumentation standard: the probe can therefore be connected to any measuring or control device fitted with this socket, whatever the brand of the device, and first and foremost to the CO2 controller it comes with. Do not run the cable over a long distance alongside electrical cables, which interfere with this very weak signal, and decide where the unit will sit before fixing anything, following the actual route of the cable along the cabinet.

Allowing for the reagents needed for subsequent recalibrations

The bottles supplied with the probe each contain 50 ml, and each calibration point needs about 10 ml of fresh solution. With one recalibration a month, the recommended frequency, the buffer supplied therefore lasts about 5 months. The pH 7 and pH 4 calibration kit takes over with the same three bottles, distilled water included, and saves you from putting off a recalibration for lack of buffer.

🎯 Two-point calibration

Once connected to its controller, the probe is calibrated for the first time on the day you unpack it, even before it is installed in the tank. The bottles and test tubes in the kit are enough for this first calibration, which is done on two points separated by a rinse with distilled water. The order matters: always pH 7 first, then pH 4, never the reverse, because the first point sets the probe's zero and the second the slope of its measurement curve. Then throw away the leftover solution in the test tubes, and repeat the procedure every 30 days, 60 at most, since the probe ages continuously and each calibration compensates for this drift.

🗓️ A part that can be replaced

Allow about 24 months. Your electrode ages chemically from the day it is made, and this ageing shows itself before it becomes a problem: the reading takes longer and longer to stabilise in the buffer solution, and then calibration no longer reaches a correct value. At that point, replace it, because a worn probe controlling a gas injection puts the fish at risk. Note the commissioning date on the casing or in a notebook: it is the only way to know where you stand 2 years later, as an electrode carries no counter.

A controller that displays the probe voltage lets you track this wear in figures. A new probe delivers roughly 0 mV in pH 7 buffer, and its voltage changes by about 59 mV per pH unit, which is around 177 mV in pH 4 buffer. As it ages, two things change: the voltage at pH 7 drifts away from zero, for example towards 28 mV, and the difference per pH unit decreases, for example to 46 mV. The JBL control computer accepts a probe as long as the offset at pH 7 stays below 115 mV and the slope exceeds 35 mV per unit; beyond that, it rejects the probe at the end of calibration.

🧫 Placement and maintenance

Fix your probe with the two suction cups supplied, vertical or slightly tilted, tip pointing down, in a well-circulated area that is dimly lit. The orientation matters: if placed horizontally, it ends up trapping an air bubble against its membrane, and the displayed value becomes unstable. A shaded position slows the growth of algae that would settle on the glass and skew the measurement. If a deposit still forms on it despite this, clean the tip with a soft cloth, dabbing gently and never rubbing, then recalibrate straight away. When out of the water, always put the storage cap back on, and store a probe left unused for several weeks in a suitable storage solution rather than in clean water.

In aquaponics, continuous monitoring is particularly useful, because the pH of a system where nitrification is active falls slowly, week after week, as the alkalinity is consumed. A probe installed in the sump or in the fish tank shows this trend well before a weekly test flags it, and it tells you when the buffer needs to be topped up. Place it away from the water inlet of the grow beds and from any addition of pH adjuster, so that it measures the system water and not that of an input that has not yet mixed in. The article on pH control in aquaponics details the possible corrections.

Technical specifications

The electrode

Filling
GelNothing to top up, unlike a liquid-electrolyte electrode.
Body
PlasticLess fragile than an all-glass body.
Control
Tested one by oneSupplied with its individual test report.
Storage
Cap filled with solutionThe tip must never dry out.

Connection

Connector
BNC
Cable length
2 mKeep it away from electrical cables along its entire length.

Service life and calibration

Replacement
Approximately 24 months
Calibration
Every 30 days60 days at most, always pH 7 first, then pH 4.

To budget for separately

Subsequent recalibrations
pH 7 and pH 4 solutions

2 further specifications are available in the detailed view.

In the box

  • 1 gel-filled pH electrode, 2 m cable and BNC connector
  • 1 storage cap
  • 2 fixing suckers
  • 3 graduated test tubes
  • 1 pH 7.0 buffer solution bottle, 50 ml
  • 1 bottle of pH 4.0 buffer solution, 50 ml
  • 1 bottle of distilled water, 50 ml

Electrode type, cable length, connector, kit contents, individual inspection, average service life, voltages, and calibration schedule taken on 07/10/2026 from the data sheet and instruction manual of manufacturer JBL, reference 6465100.

Manufacturer and product safety

Manufacturer
JBL GmbH & Co. KG
Postal address
Dieselstraße 3, 67141 Neuhofen, Allemagne
Website
www.jbl.de

Information provided under Regulation (EU) 2023/988 on general product safety.

Estimate your
delivery time

This probe has a glass tip and is supplied protected in its case. It is shipped together with the rest of your order, the postage for which is calculated at checkout according to your destination.

Frequently asked questions

10 questions

6 key questions, 10 in the detailed view

You may also like

Let us talk about your project

A question about this product or your setup? Our team will answer and advise you.

Interest-free instalment payments

Offered depending on the cart amount, at checkout.

Delivery in 2 to 15 working days

Depending on the products and shipping sites. Estimate by destination in the estimator on this page.

After-sales service 7 days a week by email or chat

Our team answers all your questions.

Shop responsibly

Become part of the change.