Extraction controller for temperature, humidity and negative pressure

Regular price 169,00 €
Regular price Sale price 169,00 €
56,33 € × 3 with no fees

This GSE digital controller varies the speed of an extractor fan and an air-intake fan according to the temperature and humidity read by its 4 m remote probe. Four dials set the target values, the minimum speed and the negative pressure of a closed greenhouse, a grow room or a seedling chamber.

Ref. TK-GSE-HUMTEMPDEP·Climate controller
100 % secure payment
Visa Mastercard American Express PayPalCartes Bancaires Apple Pay Shop Pay Bancontact EPS KlarnaMobilePayGoogle Pay BizumSatispay

The summary

  • What you receive: a GSE controller with two outlets and its probe on a 4 m cable.
  • What it controls: the speed of the extractor and of the air intake, according to heat and humidity.
  • The settings: four dials, three indicator lights, and a minimum speed of 20 to 100%.
  • What to connect: two fans with AC motors, within the load shown on the label, 2 A per outlet with no checks needed.
  • In an aquaponic greenhouse: a humidity setpoint that keeps the air below 85%.
  • With a heater: a separate probe thermostat, set below the temperature setpoint.

Ventilation controlled by temperature and humidity, with adjustable negative pressure and minimum speed

Extraction set by hand suits the day you set it, rarely the following night. The GSE controller adjusts the speed of an extractor fan and an air intake fan by itself, continuously, based on the temperature and humidity measured by a probe placed in the middle of the crops. It responds to both values at once: air that is too hot or too humid makes the extraction speed up, and the ventilation drops back to its minimum speed as soon as both values are back below their setpoints.

🎚️ Four dials, three indicator lights

The controls are all on the front panel. One dial sets the maximum temperature, another the humidity level, from 30 to 100%, a third the minimum speed of the fans, either off or from 20 to 100%, and the last the negative pressure, that is, the difference in speed between the air intake and the extraction. Three indicator lights show which control is active, so you can see at a glance whether it is heat or humidity that is running the fans. The probe, mounted on a 4 m cable, goes at leaf height, while the control box is fixed outside the growing space.

Two outlets

One marked socket for the extractor fan, one for the air intake, loaded according to the appliance's label.

Adjustable negative pressure

The air intake runs more slowly than the extraction, and the room draws in air through the intended opening.

A 4 m probe

Mounted on a low-voltage cable, it can be placed in the middle of the crops, away from the control box.

A thermal safety cut-out

Two internal sensors cut the unit off at around 75 °C, and a red indicator light signals the shutdown.

⚙️ How it controls the fans

The controller works like a dimmer: it varies the voltage sent to the two sockets, and the motor of each fan runs faster or slower accordingly. As long as the temperature and humidity stay below their set points, the fans run at the minimum speed you have chosen, or stop if the dial is at zero. As soon as either value exceeds its set point, the speed increases: it reaches its maximum 2 °C above the temperature set point, or 10 points above the humidity set point, then drops back once the air has returned to the desired range. Below both set points, the air intake stops by default, and only the extractor keeps its minimum speed. This gradual operation spares you abrupt full-power starts and the sudden cooling they cause in a small greenhouse.

A thermo-hygrometer as a reference for the probe

The controller only shows three indicator lights, yet deviations often happen in the early morning, when nobody is looking. The digital greenhouse thermo-hygrometer placed near the probe records the night's minimums and maximums. That way, every morning during the first week, you can check that the humidity setpoint has held, then adjust the dial by one notch if the air has gone past your threshold.

Variable-speed fans

The controller varies the voltage sent to the fans, like a dimmer. Connect compatible AC-motor extractor fans to it, within the load printed on the label, 2 A per output until it has been checked, and never a unit with an electronic motor that has its own controller. Check the settings after 24 hours, then after every change of ducting or filter.

The extractor fans that accept this variation are those with an AC motor that is controlled by voltage, such as external-rotor models, which their manufacturer declares compatible with a speed controller. Electronically commutated motors, known as EC, driven by a control signal, and models with two switched speeds cannot be connected to this unit. The load permitted per socket is read from the label or in the instructions, because published values range from 2 A to 600 W: until it has been checked, count on 2 A, i.e. about 460 W, and keep a 20% margin. A more powerful motor goes through a contactor. If you have only one fan, connect it to the extraction output: the controller then regulates the extraction alone, with fresh air entering through a passive opening.

Negative pressure means running the air intake slightly slower than the extraction. The room is then under slight negative pressure, and air enters only through the intended openings rather than escaping through the gaps around a door or a cover. Stale air passes entirely through your extractor, and through its carbon filter if it has one, while the walls of a grow room are drawn slightly inwards. When you open the door, a gentle draught inwards confirms the setting is right; if it is missing, reduce the speed of the air intake.

🐟 Humidity in an aquaponic greenhouse

A closed aquaponic greenhouse in winter fills with water evaporated from the fish tank and transpired by the grow beds. Above 85% relative humidity, condensation beads on the leaves and opens the door to grey mould, which sets in when humidity reaches 93% for 8 to 12 hours, at temperatures of 13 to 18 °C. Set to a humidity target of around 80%, the controller speeds up extraction just enough to renew the humid air, without chilling the greenhouse by running the ventilation flat out all the time.

At night, the air cools and its relative humidity rises without the amount of water changing, so the controller often restarts the extraction towards early morning. Keep the minimum speed low in winter, so as not to draw in cold air continuously, and warm the fresh air if needed with a duct heater controlled by a probe thermostat. In summer, the temperature setpoint takes over: vegetables grow best between 21 and 24 °C, and an overly hot greenhouse also warms the fish water, which then holds less oxygen. The guide to protecting your aquaponic system in winter covers cold-season ventilation in detail.

🔧 Installation and adjustment

Mount the unit outside the growing space, on a non-flammable wall, in concrete or brick, with 20 cm of clearance on each side, away from watering and condensation, and bring in only the probe. Plug the extractor fan and the air intake each into the socket marked with its name, then set the dials in this order: the temperature and humidity not to be exceeded, the minimum speed at 20 or 30%, and the negative pressure at mid-range. Then watch the indicator lights for a day, noting at what times heat or humidity triggers the speed-up, and adjust one dial at a time.

Position the probe at leaf height, in the shade of the lamps and away from the air intake, where a cold draught would distort the reading. In an aquaponic greenhouse, also avoid placing it directly above the fish tank, where the air is more humid than at crop level. The 4 m cable can be extended when the unit needs to sit further away, for example in a neighbouring utility room. Finally, review your settings whenever you change the ducting, the filter or the season, because the speed you need varies with the resistance of the circuit and the outside air.

📦 What's in the box

The package contains the controller, ready to plug into a 230 V mains socket, and its temperature and humidity probe on a 4 m cable. The fans connect directly to the two sockets on the unit, the extractor on one side and the air inlet on the other, with no extra wiring. The unit measures 16 x 10 x 9 cm and is easily fixed against a wall or an upright, within arm's reach so you can adjust your settings through the seasons.

⚡ Load, heat and protection

The controller sets the speed using an electronic component, a triac, which chops the voltage sent to the motors. This method suits external-rotor AC motors whose rating plate states that they accept a speed controller, and whose starting current briefly exceeds their running current. The triac heats up as it works: that is why the instructions call for a non-flammable wall and 20 cm of air around the housing, and why two sensors cut everything off at around 75 °C. After such a shutdown, the red light flashes until you unplug and replug the unit; give it more air before restarting it. When plugged in, the controller initialises for about ten seconds, with the fans at 50%, then begins regulating. Connect it to an earthed wall socket, on a circuit protected by a 30 mA RCD, and not to an extension lead. The housing is rated IP44 at least: it withstands splashing water, but not running water. The probe, for its part, works at very low voltage and can safely be placed in the humid air of the greenhouse.

Technical specifications

Regulation

Parameters
Temperature, humidity, negative pressure
Humidity setpoint
30 to 100% RH
Minimum speed
Off or 20 to 100 %
Probe
4 m cableExtendable for a box placed further away
Ramping up speed
Maximum at +2 °C or +10 % RH
Air intake below the setpoint
Off by default

The device

Outlets
2, extractor and air inletLoad to be read from the label; 2 A per socket without checking, 20% margin
Control
Voltage fluctuationFor motors with adjustable speed control, never EC
Feeding
230 V, 50 Hz
Dimensions
16 x 10 x 9 cm
Safety
Cut-off at around 75 °CRed light, restart by plugging back in
Display
3 regulation indicator lights
Protection
IP44Water splashes, no run-off
Fitting
Non-flammable wall, 20 cm of air

6 further specifications are available in the detailed view.

In the box

  • 1 GSE controller for temperature, humidity and negative pressure
  • 1 temperature and humidity sensor on a 4 m cable

Values from the manufacturer's instructions and from the brand's resellers. Humidity guidelines based on the universities of Ohio and Connecticut.

Manufacturer and product safety

Manufacturer
GSE

Information provided under Regulation (EU) 2023/988 on general product safety.

Which controller for a humid greenhouse?

Three two-output controllers for extraction and air intake.

With or without humidity measurement? This model speeds up extraction when the air becomes too humid; the other two only react to heat.

Measures humidityTemperature onlyHow to adjust the speedProbe length (m)Load per outletDisplayPrice
Recommended
Extraction controller for temperature, humidity and negative pressureYour choice
YesNoDials for minimum speed and negative pressure4 mOn the label, 2 A by defaultIndicator lights169,00 €
Extraction controller for temperature and negative pressure, 2 outletsYour choiceNoYesDials for minimum speed and negative pressure4 mOn the label, 2 A by defaultIndicator lights114,90 €
Learning-speed extraction controller, 2 x 7 AYour choiceNoYesSpeed learned, then stabilised2 m7 ADigital display139,00 €
Extraction controller for temperature, humidity and negative pressureRecommended
Regulation
Measures humidityYes
Temperature onlyNo
How to adjust the speedDials for minimum speed and negative pressure
Probe length (m)4 m
The connection
Load per outletOn the label, 2 A by default
DisplayIndicator lights
Extraction controller for temperature and negative pressure, 2 outlets
Regulation
Measures humidityNo
Temperature onlyYes
How to adjust the speedDials for minimum speed and negative pressure
Probe length (m)4 m
The connection
Load per outletOn the label, 2 A by default
DisplayIndicator lights
Learning-speed extraction controller, 2 x 7 A
Regulation
Measures humidityNo
Temperature onlyYes
How to adjust the speedSpeed learned, then stabilised
Probe length (m)2 m
The connection
Load per outlet7 A
DisplayDigital display

Manufacturers' figures, taken from their instructions and data sheets.

Documents & manuals

GSE controller manual

Installation, adjusting the settings, the speed and the negative pressure, safety, in eighteen languages including French.

PDF · 2,9 Mo

Download

Estimate your
delivery time

The controller ships in its original box from a distributor's warehouse in France. The exact shipping cost is shown in the basket.

Frequently asked questions

10 questions

6 key questions, 10 in the detailed view

You may also like

Let us talk about your project

A question about this product or your setup? Our team will answer and advise you.

Interest-free instalment payments

Offered depending on the cart amount, at checkout.

Delivery in 2 to 15 working days

Depending on the products and shipping sites. Estimate by destination in the estimator on this page.

After-sales service 7 days a week by email or chat

Our team answers all your questions.

Shop responsibly

Become part of the change.