16 A multi-socket block, 3 or 4 sockets

Regular price 8,90 €
Regular price Sale price 8,90 €

This white power strip powers 3 or 4 appliances from a single wall socket, up to a total of 16 A. The 3-socket model has a 1.5 m cable, the 4-socket model a 1 m cable.

Ref. TK-MULTIPRISE-3·Electrical equipment
Number of sockets : 3 sockets
100 % secure payment
Visa Mastercard American Express PayPalCartes Bancaires Apple Pay Shop Pay Bancontact EPS KlarnaMobilePayGoogle Pay BizumSatispay

The summary

  • What you receive: a white multi-socket block, with 3 or 4 sockets depending on the version.
  • The limit: 16 A in total, or about 3,680 W at 230 V.
  • The right calculation: add up the power of all the connected appliances before switching them on.
  • Near water: a block placed high up, above the level of the fish tanks, never over them.
  • In aquaponics: pumps kept separate from the lighting, with the residual current device and drip loops that the FAO calls for.
  • Maintenance: cables and plugs inspected at every filter clean.

For plugging a pump, a timer and a heater into a single wall socket

Around a grow bed or an aquarium, electrical appliances multiply quickly: a pump, an air pump, a heater, a light and its timer. This power strip brings together 3 or 4 of these connections on a single wall socket. Both versions handle 16 A in total, i.e. about 3,680 W at 230 V, and differ in their number of sockets and the length of their cable, 1.5 m for the 3-socket model and 1 m for the 4-socket one.

⚡ Adding up the power ratings

The 16 A limit applies to all the connected appliances together, not to each socket. A 30 W pump, a 5 W air pump, a 50 W LED light and a timer stay very far below that ceiling. A 2,000 W fan heater or two radiators, on the other hand, use up most of it on their own. Before plugging in, add up the wattages printed on your appliances' labels, and keep a separate wall socket for powerful heating appliances.

The choice between the two versions depends mainly on the distance to the wall socket and the number of appliances in your setup. A NFT hydroponic kit with pump and timer, complete with lighting, already takes up several sockets. If you add an air pump or a water heater, the 4-socket version saves you from having to plug in a second one elsewhere, provided the 1 m cable reaches your wall socket.

🧭 Spreading out the equipment

Not all the devices in a system are equal. The water pump and the air pump maintain the circulation and oxygen that the fish depend on: they must run without interruption, whereas the lighting can go off without harm. So group these two pumps on the same power strip, which you never unplug, and put the lighting and timer on a second strip or on another wall socket. That way you can move a lamp, replace a timer or switch off the light without risking stopping the water circulation by mistake.

A timer on one of the sockets

Plug your horticultural lighting into a daily timer, itself plugged into a socket on the power strip, and leave the pump and aeration on the other sockets, running continuously. This automates the day length without touching the rest of the circuit.

Never plug an extension lead into another extension lead

Do not plug one power strip into another, and never place it on the floor of a greenhouse or within reach of splashes. Connect it to an earthed wall socket protected by a 30 mA residual current device, which is essential near water.

🐟 Near a fish tank

In an aquaponic or hydroponic setup, water circulates just a few tens of centimetres from the electrical connections. Mount the unit high up, on a shelf above the level of the tanks, and run each appliance cable down in a loop lower than the socket: a drop that runs along the cable then falls at the low point instead of reaching the plug. This drip loop needs a little slack in each cord, which also guides the choice between the 1 m and the 1.5 m cord. The guide to building an aquaponic system at home covers installing the equipment around the tanks in detail.

The FAO guide to small-scale aquaponics devotes a chapter to safety at work and starts with electricity. It asks that the installation always be protected by a residual current device, which cuts the power if electricity leaks into the water, ideally fitted by an electrician at the consumer unit, or failing that as a plug-in adapter sold in DIY shops. It also recommends never running cables above fish tanks or filters, protecting plugs and sockets from rain, splashes and damp, and using drip loops wherever a cable runs down to a socket.

🔎 Check regularly

The rule never to plug one power strip into another comes down to how current adds up. The power of the devices plugged into the second strip is not shared out: it all passes through the first strip, through its plug and through the wall socket, which then carry the sum of both and heat up beyond what they were designed for. The same reasoning applies to an extension lead: one extension lead only, followed by one power strip only, and a total that stays below the lower of the two limits. If four sockets are no longer enough, it is a sign that you need a second wall socket, or a multi-socket timer box for the lighting, rather than one more power strip.

The cable should always be unrolled in full, even if it seems too long: coiled or folded under a heavy load, it retains its heat and may overheat. The power supply is designed for indoor use, in a dry room or the sheltered part of a greenhouse. Outdoors or beside a pond, suitable equipment has at least an IP44 protection rating, and a waterproof socket installed by an electrician is a far better choice than any unit left on the grass. Finally, replace a unit whose casing has yellowed or melted, whose socket no longer grips the plugs, or whose cable is split.

The same guide advises inspecting cables and appliances often, and replacing a bare wire, a frayed cord or a faulty piece of equipment without delay. Take the opportunity of every filter clean or partial water change to check the power block: a plug that runs hot, a yellowed casing or a trace of limescale on the plastic point to an overload or to damp reaching the contacts. In a greenhouse, where water-laden air condenses at night on cold surfaces, this check matters even more.

Fix the block to an upright or under a shelf rather than letting it dangle from its cable, and label each plug with the name of the appliance. The day a pump has to be unplugged in an emergency, you find it first time, without accidentally cutting the aeration or the heating. Finally, keep the block in a dry, indoor spot: it is not designed for outdoor use, and a waterproof enclosure is still required for any socket installed outside, beside a pond.

Technical specifications

The two versions

3-socket version
1.5 m cable
4-socket version
1 m cable

Electricity

Maximum current
16 A in total
Maximum power
Approximately 3,680 WCalculated at 230 V, all appliances combined

The block

Colour
White
Use
Indoors, in a dry place

To allow for in addition

Wall socket
With earth and 30 mA RCD
Location
Shelf kept dry, above the trays

In the box

  • 1 power strip with 3 or 4 sockets, depending on the version chosen, supplied with its cable and plug

Values from the distribution data sheet, power calculated at 230 V. Wiring rules from the FAO aquaponic manual, Legrand and the Swiss Federal Inspectorate for Heavy Current Installations.

Estimate your
delivery time

The multi-socket block is sent from a distributor's warehouse in France, as a small parcel. The exact shipping cost is shown in your basket.

Frequently asked questions

6 questions

6 key questions

You may also like

Let us talk about your project

A question about this product or your setup? Our team will answer and advise you.

Interest-free instalment payments

Offered depending on the cart amount, at checkout.

Delivery in 2 to 15 working days

Depending on the products and shipping sites. Estimate by destination in the estimator on this page.

After-sales service 7 days a week by email or chat

Our team answers all your questions.

Shop responsibly

Become part of the change.