Digital hygrostat with 5 m probe, 16 A

Regular price 7,200.00 RSD
Regular price Sale price 7,200.00 RSD
2,400.00 RSD × 3 with no fees

This digital hygrostat controls a humidifier or a dehumidifier according to the humidity measured by its 5 m probe, placed in the middle of the crops. Its socket controls appliances up to 16 A, from a flame-retardant housing with a digital display and buttons, which keeps its settings after a power cut.

Ref. TK-CLIMATE-HYGRO-16A·Humidistat
100 % secure payment
Visa Mastercard American Express PayPalCartes Bancaires Apple Pay Shop Pay Bancontact EPS KlarnaMobilePayGoogle Pay BizumSatispay

The summary

  • What you receive: a Cli-mate humidistat with a controlled socket and its humidity probe on a 5 m cable.
  • The principle: the socket switches on or off according to the relative humidity read by the probe.
  • The appliances: a humidifier or a dehumidifier, up to 16 A.
  • The probe: placed at leaf height, away from the humidifier's jet.
  • The housing: digital display, setting buttons and memory of the set points after a power cut.
  • In an aquaponic greenhouse: a regulated dehumidifier limits condensation above the beds.

Humidity controller with remote probe for greenhouse, tent and cutting room

A humidistat does for humidity what a thermostat does for temperature: it continuously compares the relative humidity of the air with a setpoint, then switches on or off the appliance that corrects it. This Cli-mate model plugs in between the wall socket and a humidifier or dehumidifier, and measures the air using a probe mounted on the end of a 5 m cable. You set the target to the exact percentage point on its digital display, using two buttons, and the unit then holds the humidity of a greenhouse, a grow tent or a cutting room on its own.

Control is on/off: the socket does not modulate the power of the connected appliance, it either supplies it or cuts it off. Plugged into a dehumidifier, the humidistat switches it on as soon as the air becomes more humid than the setpoint, then stops it once humidity has dropped 3 points below the setpoint. Plugged into a humidifier, it does the opposite and restarts misting when the air dries out, up to 3 points above the setpoint. Its socket accepts up to 16 A, or roughly 3,600 W at 230 V, which comfortably covers a compressor dehumidifier, the most power-hungry appliance of the lot.

📍 The probe in the heart of the crops

The 5 m cable lets you place the probe where humidity really matters, in the middle of the foliage, rather than next to the wall socket. Avoid the plume of a humidifier, which would make the unit switch off before the rest of the greenhouse has gained any humidity, and keep it away from cold panes where the air fills with condensation. Placed in the shade, at plant height, the probe gives you a reading that represents the air your crops actually breathe.

A protected wall socket, in a dry place

A dehumidifier sometimes runs for hours on end, and a power strip or a coiled extension lead heats up under a prolonged load. Plug the humidistat directly into an earthed wall socket protected by a 30 mA residual current device, since the greenhouse remains a damp environment. Finally, fix the unit out of reach of watering and the grow beds, with the probe cable routed without tension.

With a dehumidifier

The unit starts up when the air rises above the set point and switches off 3 points below it.

With a humidifier

Misting starts again as soon as the air dries below the setpoint, which is useful for cuttings and seedlings.

The 5 m probe

It is placed in the middle of the crops, in the shade, away from the humidifier's jet and cold windows.

A unit to keep dry

It is fixed out of reach of splashes and the watering jet, away from condensation.

A thermo-hygrometer to set the target value

Placed near the probe, a digital thermometer and hygrometer displays both temperature and humidity, and stores the night's extremes in its memory. You can thus see when the air becomes saturated, often in the early morning once the greenhouse has cooled, and you set the humidistat's setpoint from that reading rather than at random. It also lets you check that the probe is reading accurately during the first few days.

Relative humidity depends on temperature. According to the University of Massachusetts, air at 21 °C can hold twice as much water as air at 10 °C, so a greenhouse that cools down in the evening sees its relative humidity climb without any water being added. As soon as a leaf's temperature drops below the dew point, water settles on it: in air at 15.5 °C and 85% humidity, a leaf about 3 °C colder is already covered in condensation, and at 95% a difference of half a degree is enough. The humidistat setpoint should therefore be based on night-time and early-morning readings, rather than on the afternoon air.

🌿 Humidity benchmarks

The right setting depends on the stage of your crops. Seedlings and cuttings, whose roots do not yet make up for the evaporation from the leaves, thrive in humid air, at around 70 to 80%. Young plants in full growth are content with 50 to 65%, while flowering and fruit set call for drier air, 40 to 50%, which limits mould on the flowers. You therefore lower the humidistat setting as the season progresses, and you can reread the article on germination failures if your seedlings struggle despite well-maintained humidity.

🐟 The set point of an aquaponic greenhouse

An aquaponic greenhouse holds a large area of water, between the fish tank and the grow beds, and this water evaporates day and night. Beyond a certain threshold, foliar diseases find the conditions they need: botrytis takes hold when humidity exceeds 93% for 8 to 12 hours, according to the University of Connecticut's plant protection service. The University of Massachusetts gives humidity limits not to be exceeded depending on temperature, to prevent disease: 83% at 10 °C, 89% at 16 °C, 91% at 20 °C and 95% at 30 °C. It also advises, in the evening after sunset and at first light, ventilating then heating two to three times an hour, to replace humid air with drier air. The humidistat handles the dehumidifier's share between these air changes, and pruning dense-foliaged crops, as recommended by the University of Kentucky, opens up the centre of the plants to airflow. Our guide to protecting your aquaponic system in winter details the other cold-season settings, from ventilation to insulating the greenhouse.

⚡ Mode, memory and wiring

One button selects the mode, humidifier or dehumidifier, and the setpoint can be set from 0 to 99% relative humidity. The unit stores the mode and setpoint in memory: after a power cut, it resumes control on its own, provided that the connected appliance restarts by itself, with its switch left in the on position. Models with an electronic button that go back to standby when the power returns are therefore not suitable. A compressor dehumidifier draws a higher current at start-up than its stated consumption, and it can run for hours without stopping: keep a 20% margin below the 16 A, that is 12.8 A at most, and plug the humidistat alone into an earthed wall socket, never into a multi-plug adaptor or a coiled extension lead. The circuit must be protected by a 30 mA residual current device. Its instructions classify it as IP20, with no protection against water: treat it as an appliance that must be kept away from water, placed in a dry spot in a room between 10 and 40 °C, and let only the probe enter the humid air.

Technical specifications

Regulation

Controlled variable
Relative air humidity
Control
All or nothingThe socket switches on or off, with no variation in power
Probe
5 m cable
Adjustment
Digital display and buttons
Setpoint range
0 to 99% RH
Trigger differential
3 points around the setpointAvoids repeated restarts

Electricity

Maximum load
16 A, around 3,600 WAt 230 V
Protection
Keep the control box dryIP20 according to the manual, to be protected from splashes
Memory
Mode and setpoint retainedRestarts on its own after a power cut
Dimensions
5.5 x 4 x 13.5 cm

Usage

Controlled devices
Humidifier or dehumidifier
Places
Greenhouse, grow tent, propagation room

To allow for in addition

A device to control
Humidifier or dehumidifierFitted with a switch that stays in the on position
A check on the reading
Digital thermo-hygrometer

6 further specifications are available in the detailed view.

In the box

  • 1 Cli-mate 16 A hygrostat with controlled socket
  • 1 humidity probe on a 5 m cable

Manufacturer values (datasheet), trigger differential recorded at a retailer. Humidity benchmarks from the Universities of Massachusetts, Connecticut and Kentucky.

Manufacturer and product safety

Manufacturer
Cli-mate

Information provided under Regulation (EU) 2023/988 on general product safety.

Estimate your
delivery time

The exact shipping cost is calculated at checkout, based on the total weight of your order and the destination. Lead times start from dispatch and remain estimates. For a destination not listed here, write to us at contact@univers-aquaponie.com.

Frequently asked questions

8 questions

6 key questions, 8 in the detailed view

You may also like

Let us talk about your project

A question about this product or your setup? Our team will answer and advise you.

Interest-free instalment payments

Offered depending on the cart amount, at checkout.

Delivery in 2 to 15 working days

Depending on the products and shipping sites. Estimate by destination in the estimator on this page.

After-sales service 7 days a week by email or chat

Our team answers all your questions.

Shop responsibly

Become part of the change.