Horticultural lighting timer box, 4 to 12 sockets

Regular price Dhs. 493.00
Regular price Sale price Dhs. 493.00
Dhs. 164.33 × 3 with no fees

This contactor timer box controls four to twelve 600 W horticultural lamps from a single Grässlin timer. It withstands the inrush current of the ballasts at start-up, which household timers cannot handle, and keeps the time for 36 hours in the event of a power cut.

Ref. TK-GSE-TB4X600·Timer
Number of sockets : 4 sockets of 600 w
100 % secure payment
Visa Mastercard American Express PayPalCartes Bancaires Apple Pay Shop Pay Bancontact EPS KlarnaMobilePayGoogle Pay BizumSatispay

The summary

  • What you receive: the control box, its 600 W sockets and its 16 A power leads.
  • What it is for: switching 4 to 12 horticultural lamps on and off together, without overloading a timer.
  • Programming: in 15 or 30 minute steps over 24 hours, depending on the dial series.
  • What it requires: a separate 16 A circuit for each power lead.
  • In aquaponics: for lighting only, never for the pump or the aeration of the fish tank.
  • Safety: an IP20 box kept in a dry place, with circuits protected by a 30 mA residual current device.

Control of several horticultural lamps on a single day and night cycle

A 600 W discharge grow lamp, whether high-pressure sodium or metal halide, runs through a ballast that draws a high current at start-up. Plugged in several at a time on an ordinary socket timer, these lamps will make it overheat and burn out. The GSE Timer Box separates the two functions: a clock controls a contactor, in other words a power relay, and it is the contactor that takes the inrush current of all the lamps at once.

⏱️ A timer, a contactor, sockets

You set the Grässlin mechanical timer on the front by pressing in its pins: each one corresponds to 15 or 30 minutes of lighting on a 24-hour dial, depending on the dial series: the interval is printed on its rim. The cycle you choose then applies to all the sockets on the unit, arranged along its sides. A 36-hour power reserve keeps the time through a power cut, so the photoperiod picks up without any shift when the mains supply returns.

The contactor is a power switch controlled by the timer. Its contacts are rated for the inrush current of a magnetic ballast, which draws far more at start-up than its running current, and for that of electronic power supplies and LED drivers, which charge their capacitors in a fraction of a second. On a domestic timer, these repeated surges eventually weld the contacts together, and the lamp no longer switches off. Here, the timer carries only a small control current, and all the lamps switch on together, at the same instant, at the chosen time.

6 sockets of 600 W

Total power of 3,600 W, shared across two 16 A power cables.

12 sockets of 600 W

Total power of 7,200 W, spread across three 16 A power cables.

Dedicated lines, a dry room

Each heating cable needs its own 16 A line, protected at the consumer unit by a circuit breaker and a 30 mA RCD, with no other powerful appliance on it. Have the installation checked by an electrician before first switching on. The housing is rated IP20: it should be placed in a dry technical room, out of reach of splashes, watering and the condensation of a greenhouse.

Spread the lamps across the cables

When not all the sockets are in use, divide the lamps equally between the socket groups, so that each line carries the same load. Note on the unit which lamp is on which cord: a tripped circuit breaker can then be diagnosed at a glance.

Choose the model according to the power actually connected rather than the number of lamps today. Each socket is designed for a lamp of 600 W at most, and a smaller lamp, of 250 or 400 W, or a 300 W LED, can be plugged in too. Keep one or two sockets free for expanding the crop, and share the lamps equally between the cords. The 4-socket model is enough for a small grow room, while the 12-socket model equips a whole room, provided there is one electrical supply line per cord.

🌱 Supplementary lighting for a greenhouse

From November to February, natural light drops to the point of slowing down lettuces and tomatoes in the greenhouse. Supplementary lamps switched on early in the morning and at the end of the day extend the photoperiod, and the control box operates them all together, at the times you have chosen. The same principle applies in a grow room fitted with several lamps, where a regular cycle matters as much as intensity. The hanging system then adjusts the height of each lamp above the foliage.

🐟 Lamps on the timer, pump separate

In your aquaponic greenhouse, only the lighting goes through the Timer Box. The water pump and the air pump stay on their own circuit, powered continuously, because the fish and the filtration bacteria need oxygen day and night. A pump switched off at the same time as the lamps would cause dissolved oxygen to drop within a few hours. No timer should therefore replace the continuous running of the pump that circulates the fish water, and the aeration must never be switched off: plug them into a permanent wall socket, marked with a label. A thermo-hygrometer placed near the crops also shows the heat given off by the lamps, which needs watching in a closed greenhouse.

Plants in the nursery, which will later move on to the grow beds, are content with 14 to 16 hours of light a day, as recommended by Iowa State University for seedlings raised under lamps. Lamps also warm the air: in a closed aquaponic greenhouse, a row of 600 W lamps raises the temperature of the water in the tanks, which suits tilapia and trout far less, as trout prefer water below 18 °C. Scheduling the lighting at night, when the greenhouse is at its coldest, spreads this heat more evenly, and a thermometer in the tank shows you the effect on the water from the first week.

⚡ Circuits, RCD and a dry room

A 16 A line at 230 V can carry about 3,680 W, but a sound installation does not load it to its maximum continuously: keep a 20% margin, which comes to about 2,900 W per cable. Four 600 W lamps, or 2,400 W, stay comfortably below that. Each cable plugs directly into an earthed wall socket, never into an extension lead or a multi-socket adaptor, because the cable of a coiled extension lead heats up under a continuous load lasting several hours. The circuit that supplies the box must be protected by a 30 mA residual current device (RCD), like all circuits in a home under the NF C 15-100 standard. Rated IP20, the box is protected against the entry of fingers, not against water: it should be mounted in a dry utility room or in a closed cabinet, and only the lamp cables run through to the greenhouse, with a loop below each socket so that water drips off before it gets there.

🔧 Programming and maintenance

Set the timer before plugging in the lamps: turn the dial until the current time is level with the marker, push in the tappets for the lighting period, then check the first switch-on. The mechanical timer does not follow the change to summer or winter time by itself, so you move the dial by one hour twice a year, without touching the tappets. Once a season, unplug the unit, dust it, check that the plugs stay cool after several hours of running and replace any damaged cable. The unit is guaranteed for 2 years, provided you register the warranty sheet at the time of purchase.

The package contains the housing with its Grässlin timer, its 600 W sockets, numbering 4, 6, 8 or 12 depending on the model you choose, and its 16 A power cords, one per group of sockets. The lamps, ballasts and hangers are not supplied, and each socket takes the plug of a lamp or its ballast.

Technical specifications

The control unit

Sockets
4, 6, 8 or 12 of 600 WFor sodium or metal halide ballast lamps
Total power
2,400 to 7,200 W
Clock
Grässlin mechanism, notchedOne notch for every 15 or 30 minutes, depending on the series
Power reserve
36 hours

The installation

Feeding
230 V, 50 Hz
Cords
16 A, one per group of socketsA separate electrical line for each cable, protected by a 30 mA RCD
Protection
IP20Dry room, protected from water splashes
Housing
26 x 25 x 11 cm
Switching on
All the sockets together
Warranty
2 years, sheet to be filled in

2 further specifications are available in the detailed view.

In the box

  • 1 GSE Timer Box unit with Grässlin clock
  • 4 to 12 600 W sockets, depending on the model chosen
  • The 16 A power cords, one per group of sockets

Sockets, power ratings, timer, power reserve and protection rating taken from the distributor and from retailers of the brand. Seedling lighting duration based on Iowa State University.

Manufacturer and product safety

Manufacturer
GSE

Information provided under Regulation (EU) 2023/988 on general product safety.

Which contactor box for your lamps?

Three contactor boxes for switching on several lamps from a single timer.

Sockets on the unit or remote? Two housings have their sockets on their sides, while the third moves them into two blocks on a cable, as close as possible to the lamps.

Sockets on the housingRemote sockets on a cable600 W lamps acceptedSockets rated for 600 W each315 to 630 W lamps on the same lineClockPower reserve (h)Protection ratingPrice
Recommended
Horticultural lighting timer box, 4 to 12 socketsYour choice
YesNo8YesNoMechanical, with sliding clips36 hIP20Dhs. 657.00
Relay timer power strip, 8 or 12 socketsYour choiceYesNo8NoYesAnalogue, with segment display48 hIP20Dhs. 493.00
Contactor timer, 2 banks of 4 socketsYour choiceNoYes6NoNoSegment mechanism36 hIP40Dhs. 370.00
Horticultural lighting timer box, 4 to 12 socketsRecommended
The sockets
Sockets on the housingYes
Remote sockets on a cableNo
600 W lamps accepted8
Sockets rated for 600 W eachYes
315 to 630 W lamps on the same lineNo
The timer and the control box
ClockMechanical, with sliding clips
Power reserve (h)36 h
Protection ratingIP20
Relay timer power strip, 8 or 12 sockets
The sockets
Sockets on the housingYes
Remote sockets on a cableNo
600 W lamps accepted8
Sockets rated for 600 W eachNo
315 to 630 W lamps on the same lineYes
The timer and the control box
ClockAnalogue, with segment display
Power reserve (h)48 h
Protection ratingIP20
Contactor timer, 2 banks of 4 sockets
The sockets
Sockets on the housingNo
Remote sockets on a cableYes
600 W lamps accepted6
Sockets rated for 600 W eachNo
315 to 630 W lamps on the same lineNo
The timer and the control box
ClockSegment mechanism
Power reserve (h)36 h
Protection ratingIP40

Manufacturers' figures, compared across the 8-socket versions.

Estimate your
delivery time

The unit is sent in a parcel of about 2 kg from a distributor's warehouse in France. The exact shipping cost is shown in your basket.

Frequently asked questions

10 questions

6 key questions, 10 in the detailed view

You may also like

Daily electronic programmer – timer plug to automate lighting and pump in aquaponics
Daily timer
Regular price Dhs. 37.00
Regular price Sale price Dhs. 37.00

Let us talk about your project

A question about this product or your setup? Our team will answer and advise you.

Interest-free instalment payments

Offered depending on the cart amount, at checkout.

Delivery in 2 to 15 working days

Depending on the products and shipping sites. Estimate by destination in the estimator on this page.

After-sales service 7 days a week by email or chat

Our team answers all your questions.

Shop responsibly

Become part of the change.