Floating pH tester with replaceable electrode

Regular price $209.00
Regular price Sale price $209.00
$69.66 × 3 with no fees

This waterproof tester measures pH to one decimal place and temperature, and it floats if you drop it in a tank. Its HI73127 electrode comes as a replaceable cartridge: when it wears out, you change the probe without buying a new device.

Ref. TK-HANNA-HI98127·Electronic tester
Customer support 7 days a week by email
Delivery within 2 to 15 business days
100 % secure payment
Visa Mastercard American Express PayPalCartes Bancaires Apple Pay Shop Pay Bancontact EPS KlarnaMobilePayGoogle Pay Satispay

The summary

  • What it measures: pH from -2.0 to 16.0 to one decimal place, and water temperature up to 60 °C.
  • The cartridge: the HI73127 electrode can be removed and replaced, the device stays.
  • Calibration: one or two points, with automatic buffer recognition.
  • At the tank side: a waterproof housing that floats, and a button to hold the reading.
  • Battery life: about 300 hours, with a charge percentage shown at power-on.
  • In aquaponics: everything you need to check each week that your water stays between 6.4 and 7.5.

Waterproof, floating field pH meter with a cartridge probe you can replace yourself

The pHep 4 HI98127 is a field pH meter designed to live at the water's edge. It displays pH to one decimal place and the temperature, it automatically compensates for the effect of heat on the reading, and its waterproof casing floats if it falls into a tub or tank. Its distinctive feature is the probe: the electrode is not fixed to the unit but forms a cartridge that you remove and replace yourself. Since a pH electrode wears out over time, however carefully it is looked after, this design extends the life of the tester well beyond that of its first probe.

🔁 A replaceable electrode

The HI73127 electrode combines a 5 mm spherical glass bulb, a silver/silver chloride reference in a gel electrolyte, and a cloth junction, all housed in a polypropylene body. It clips into the tester, and two O-rings seal the connection. When the response becomes sluggish despite cleaning, or when calibration no longer succeeds, you simply remove the old cartridge, fit the new one, and then calibrate. A temperature sensor built into the meter, a thermistor, measures the water at the same time as the pH, which allows automatic compensation.

It floats

The waterproof case floats to the surface if it slips from your hands over a tank or a cuve.

HOLD button

The reading freezes on the screen, which lets you take the probe out of the water to note the value.

Battery charge

The remaining percentage is shown at switch-on, and the device turns itself off before a weak battery skews the reading.

Celsius or Fahrenheit

The temperature is displayed in the unit of your choice, to within 0.1 degree.

🎯 Automatic calibration

Calibration is automatic, at one or two points, and the device recognises by itself the buffer in which you immerse the probe. It accepts two sets of buffers: pH 4.01, 7.01 and 10.01, the most common in Europe, or pH 4.01, 6.86 and 9.18. For aquaponic water as for a nutrient solution, calibrating at pH 7 and then at pH 4 covers the whole useful range. A stability indicator tells you when the reading has stopped changing. The buffer solution sachets supplied in the box let you calibrate from the very first use, and a pH calibration kit takes over when they run out.

Correcting the pH once the reading has been taken

A reliable measurement is only useful if you can act on it afterwards. In aquaponics, the water tends to acidify, but hard borehole water or a system start-up can on the contrary keep it too high. The liquid pH- corrector lowers water that is too alkaline in small doses, which you check with the pHep 4 between additions. This way you avoid overshooting the target and subjecting the fish to a sudden swing.

Two O-rings keep the housing watertight

When changing the cartridge, check that the two O-rings on the electrode are clean and properly seated before pushing it in. A pinched or dirty O-ring lets water reach the connector, and the reading becomes unstable. Take the same care with the battery cover, which must be fully closed.

🧴 Looking after the electrode

A pH electrode lives in moisture. After each measurement, rinse the probe with clean water, put the cap back on with a few drops of storage solution in it, and store the tester upside down so that the glass bulb stays immersed. An electrode left dry responds more slowly and wears out faster, which the replaceable cartridge makes up for, but at the cost of a new probe. Check the calibration at least once a month, and clean the probe with the cleaning solution as soon as it looks fouled, for example after repeated measurements in water heavily loaded with organic matter. Recalibrate straight after this cleaning, since the condition of the junction has changed.

The measurement itself takes very few steps. Immerse the probe in the sample, stir gently, then wait for the stability indicator to settle before noting the value, or freeze it with the HOLD button. Preferably take the water in a beaker rather than measuring in the middle of a deep pond, which lets you rinse the probe straight away and prevents it from knocking against the bottom or the sides. Note the displayed temperature along with the pH, and always measure at the same time of day, so that your readings remain comparable from one week to the next and the trend stands out clearly.

🌱 Weekly monitoring in aquaponics

In an aquaponic system, the target range is between 6.4 and 7.5. Nitrification releases hydrogen ions continuously and gradually lowers the pH, at a rate that depends on the carbonate reserve in your water. One reading a week, taken at the same time of day, is enough to see the drop coming and correct it in small doses. A floating, splash-proof tester earns its place beside the fish tank, and the article on pH regulation in aquaponics explains when and how to step in. While the system is starting up, the pH should also be checked daily, as the guide to getting an aquaponic system off to a good start explains.

The target values become clearer depending on what you prioritise. Nitrification works best above pH 7.5, whereas plants take up their nutrients better below 6.5, so systems are run in a compromise zone, between 6.4 and 7.5, which all three populations tolerate together. When the pH falls below 6.4, a base brings it back towards 7, in small doses spread over several days, and alternating hydrated lime and potassium hydroxide also supplies calcium and potassium to the plants. The carbonate hardness test completes the picture, since alkalinity, which should stay at 100 mg/L or more, slows the fall in pH. In a decoupled growing loop or a separate hydroponic tray, the same tester can finally be used to adjust the plants' solution, which you can keep more acidic than the fishes' water.

🔋 Batteries and getting started

The tester runs on 4 x 1.5 V batteries, for roughly 300 hours of continuous use. Automatic switch-off kicks in after 8 minutes of inactivity, which saves the batteries if the device is left on by mistake. The casing measures 163 x 40 x 26 mm and weighs 100 g, with a non-slip grip shell that holds well in a wet hand. Two buttons cover every function, from switching on to calibration and holding the reading, and the tool supplied in the box is used both to open the battery compartment and to change the electrode.

Technical specifications

Measuring pH

pH range
-2.0 to 16.0Resolution of 0.1 pH
pH accuracy
±0.1 pH
Temperature
-5 to 60 °CRead to a tenth of a degree, accurate to ±0.5 °C
Compensation
Automatic
Reference
Hanna HI98127, pHep 4
Housing
Waterproof and floating

Electrode and calibration

Electrode
Cartridge HI73127, replaceable5 mm spherical glass, gel electrolyte, cloth junction
Calibration
Automatic, 1 or 2 points
Recognised buffers
pH 4.01, 7.01, 10.01Or the pH 4.01, 6.86 and 9.18 series
Functions
HOLD, stability, °C or °F

Power supply and size

Batteries
4 x 1.5 V, type LR44Around 300 hours of continuous use
Automatic switch-off
After 8 min of inactivitySaves the batteries if you forget to switch it off
Dimensions
163 x 40 x 26 mm
Weight of the unit
100 g

To allow for in addition

Calibration buffer solutions
pH 7 and pH 4 buffer solutionsAs soon as the four sachets supplied are empty
Spare electrode
HI73127 cartridgeThe day the first one wears out

8 further specifications are available in the detailed view.

In the box

  • 1 pHep 4 HI98127 tester with its HI73127 electrode fitted
  • 4 1.5 V batteries
  • 2 sachets of pH 4 buffer solution and 2 sachets of pH 7
  • 1 sachet of cleaning solution and 1 sachet of storage solution
  • 1 tool for changing the batteries and the electrode

Manufacturer's values (Hanna HI98127 datasheet); box contents of the version sold in France. Aquaponic benchmarks from the FAO manual.

Manufacturer and product safety

Manufacturer
Hanna Instruments

Information provided under Regulation (EU) 2023/988 on general product safety.

Three pH meters, three probes

All three read pH to the nearest tenth and compensate for temperature. They differ in their probe, their resistance to water and their battery.

A replaceable probe, or a low entry price All three measure pH to the nearest tenth. Answer two questions and the table points to the one that suits the way you measure.

Replaceable electrodeRenewable fabric junctionFloats if it falls in the waterBattery life (h)pH rangeReferencePrice
Recommended
Floating pH tester with replaceableYour choice
YesNoYes300 h-2.0 to 16.0HI98127$209.00
Waterproof pocket pH meter withYour choiceNoYesNo800 h0.0 to 14.0HI98107$92.00
IP65 pH meter with replaceable electrode, pH and temperatureYour choiceYesNoNo300 h-2.0 to 16.0pH55$112.00
Floating pH tester with replaceableRecommended
The probe
Replaceable electrodeYes
Renewable fabric junctionNo
The housing
Floats if it falls in the waterYes
Battery life (h)300 h
pH range-2.0 to 16.0
ReferenceHI98127
Waterproof pocket pH meter with
The probe
Replaceable electrodeNo
Renewable fabric junctionYes
The housing
Floats if it falls in the waterNo
Battery life (h)800 h
pH range0.0 to 14.0
ReferenceHI98107
IP65 pH meter with replaceable electrode, pH and temperature
The probe
Replaceable electrodeYes
Renewable fabric junctionNo
The housing
Floats if it falls in the waterNo
Battery life (h)300 h
pH range-2.0 to 16.0
ReferencepH55

Values from the manufacturers Hanna and Milwaukee, datasheets and instruction leaflets.

Estimate your
delivery time

The tester is sent in its original box, as a small parcel, from a distributor's warehouse in France. The exact shipping cost is shown in your basket.

Frequently asked questions

10 questions

6 key questions, 10 in the detailed view

You may also like

Let us talk about your project

A question about this product or your setup? Our team will answer and advise you.

Interest-free instalment payments

Offered depending on the cart amount, at checkout.

Delivery in 2 to 15 working days

Depending on the products and shipping sites. Estimate by destination in the estimator on this page.

After-sales service 7 days a week by email or chat

Our team answers all your questions.

Shop responsibly

Become part of the change.