Contactor timer, 2 banks of 4 sockets
The LUMii Black Contactor connects a mechanical timer to a contactor, which powers two blocks of four sockets at the end of their cables. It switches up to eight horticultural lamps on and off together, without heating up the timer, and is placed away from the lamps, in a dry spot in the greenhouse or the room.
The summary
- What you receive: the LUMii timer and contactor box, connected to two blocks of 4 French sockets.
- How many lamps: up to 6 of 600 W or 8 of 400 W, spread over two blocks of 4 sockets.
- Programming: in quarter-hour segments, with 36 hours of power reserve.
- The right wiring: spread the lamps equally between the two blocks, on two circuits.
- In aquaponics: it controls the lighting of the grow beds, never the pump or the fish aeration.
- The location: an IP40 box, to be fixed in a dry spot, away from the tank and water splashes.
Central timer and contactor for two rows of horticultural lamps
LUMii's Black Contactor is nothing like timer boxes with built-in sockets. Its central unit, which houses the clock and the contactor, is connected by cable to two blocks of four sockets that you place wherever you like: one on each side of a polytunnel, or one per row of lamps in a grow room. The clock only controls the contactor, and it is the contactor, a power relay, that cuts and restores the current to the lamps. An ordinary timer would pass the whole load through its own contacts, which heat up and wear out; here, the clock carries only a control current, and the lamps all switch on together.
🔌 Two blocks, two lines
Each block of four sockets connects to the mains through its own plug, and its load is counted in lamps: no more than 3 lamps of 600 W, or 4 lamps of 400 or 315 W per block. The unit connects through two plugs, to be plugged into two wall sockets on different circuits, so that the load of the two blocks does not add up on a single circuit. With fewer than eight lamps, share them out equally: six 400 W lamps are connected three to each block. Horticultural LED lamps and ballast fixtures are connected in the same way, as long as each block stays under its limit.
Segmented timer
Each segment pushed in switches the lamps on for a quarter of an hour, on a 24-hour dial.
Transparent cover
A cover protects the timer from dust while still letting you see where the cycle has got to.
36-hour reserve
During a power cut, the clock keeps running, and the cycle resumes on schedule when the power returns.
French sockets
This version has French-standard sockets, with an earth pin.
The control box must stay away from water
The control box is rated IP40: it is protected against small objects, not against water. Mount it in a dry spot, away from watering, misters and the fish tank, place the socket strips up high, out of reach of any water that might run, and connect everything to circuits protected by a 30 mA residual current device.
🌱 In aquaponics
In an indoor aquaponic system or a winter greenhouse, the Black Contactor controls the lighting of the grow beds, towers or nursery, and nothing else. The water pump and the air pump run continuously, on a separate socket: dissolved oxygen must stay at no less than 5 mg/L for the fish and for the bacteria in the filter, according to New Mexico State University, and aeration switched off at night by a wiring mistake is enough to make it drop. So keep the contactor's sockets for the lamps, and mark those of the pump and the aeration with a label, so that no vital appliance ever ends up on a timed block.
The lighting duration depends on what is growing. For seedlings, the Iowa State University Extension recommends 14 to 16 hours of light a day, with tubes placed 10 to 15 cm from the seedlings. For lettuce grown soilless under LEDs, a study published in 2024 in the journal Agronomy tested photoperiods of 16 hours and then 20 hours a day depending on the growth stage. With quarter-hour segments, the timer sets these durations without difficulty, and a cycle that is fixed from one day to the next avoids growth setbacks. The heat from the lamps also matters: when it is applied at night, when the room is coldest, it helps keep the water temperature more stable, as a thermometer in the tank and a thermo-hygrometer near the crops will confirm.
Hanging the lamps at the right level
The contactor sets the time, the height of the lamps sets the intensity. An adjustable hanging system raises the lamps as the plants grow, without unplugging the cables from the power units.
🌙 Programming and maintenance
In a closed grow room, the artificial day does not need to coincide with the solar day. Placing the lighting period at night often lets you take advantage of the off-peak electricity tariff, depending on your contract. To programme it, lift the cover, turn the dial to the current time, push in the segments for the quarter-hours of lighting, then close it again. When the clocks go forward or back, the mechanical timer does not adjust itself: move the dial by one hour.
Once a season, check that the plugs remain firmly seated and cool to the touch after several hours of operation, a sign that the load is still reasonable. Dust the housing and the blocks, check the condition of the cables where they run close to structures, and replace any socket that has blackened or warped. Unplug the unit before doing any work on the lamps.
⚡ Load per block and protection
Four sockets on a block do not mean you can run four 600 W lamps. A discharge lamp ballast draws far more current at start-up than when running, and all four switch on at the same instant, so the block and its cable take a surge that the sum of the rated wattages does not show. Hence the recommended limit of 3 lamps of 600 W per block, or 4 lamps of 400 or 315 W: the fourth socket of a block loaded with 600 W lamps stays free. Horticultural LED lamps follow the same power rule, and their drivers add a very brief surge at each switch-on. The contactor protects the timer from these surges, since its power contacts switch the lamp current on and off while the timer only controls a coil. The two plugs connect to two earthed wall sockets on different circuits, protected by a 30 mA residual current device. Rated IP40, the enclosure is protected against objects larger than 1 mm, not against water: mount it somewhere dry, and place the blocks up high, away from areas where watering or condensation water could run.
🧮 Working out the load on each circuit
The calculation is done block by block, since each block has its own sheet and therefore its own line. Three 600 W lamps come to 1,800 W, or a little under 8 A at 230 V, and four 400 W lamps come to 1,600 W, or about 7 A. These loads stay well below the capacity of a 16 A line on the consumer unit, and it is this margin that absorbs the switch-on surge of the ballasts, repeated every day at the same time. If the wall circuit already supplies something else, a dehumidifier or a supplementary heater, add its power to that of the block before plugging in, and preferably use a circuit reserved for lighting. The fish tank pump and the air pump stay on a separate socket, outside the timer, so that they run without interruption.
Technical specifications
The control unit
- Sockets
- 8, in 2 blocks of 4Blocks connected to the control box by cable
- Load per block
- 3 x 600 W or 4 x 400 WOne mains plug per unit
- Clock
- Mechanical, quarter-hour segmentsUnder a transparent cover
- Power reserve
- 36 hours
The installation
- Feeding
- 230 V, 50 Hz, 2 plugsOn two separate lines
- Sockets
- French standard
- Protection
- IP40Dry room, away from water splashes
- Weight
- 1.2 kg
In the box
- 1 box with timer and contactor
- 2 blocks of 4 sockets connected to the controller
Sockets, load per block, timer, backup power reserve, protection and weight taken from the distributor and from retailers of the brand. Oxygen: New Mexico State University; seedlings: Iowa State University; lettuce: Agronomy, 2024.
Which contactor timer should you choose?
Three contactor boxes that switch on several lamps together, in an 8-socket version.
| Sockets on the housing | Remote sockets on a cable | 600 W lamps accepted | Sockets rated for 600 W each | 315 to 630 W lamps on the same line | Clock | Power reserve (h) | Protection rating | Price | |
|---|---|---|---|---|---|---|---|---|---|
| Horticultural lighting timer box, 4 to 12 socketsYour choice | Yes | No | 8 | Yes | No | Mechanical, with sliding clips | 36 h | IP20 | 159,90 € |
| Relay timer power strip, 8 or 12 socketsYour choice | Yes | No | 8 | No | Yes | Analogue, with segment display | 48 h | IP20 | 119,90 € |
| Recommended Contactor timer, 2 banks of 4 socketsYour choice | No | Yes | 6 | No | No | Segment mechanism | 36 h | IP40 | 89,90 € |
Manufacturers' figures for the 8-socket versions.
Buying guide
Which control box for lighting your crops?
Estimate your
delivery time
Your estimate
It covers preparing your order and then the transit time quoted by the carrier, counted in working days.
It is not a guaranteed delivery date: public holidays, peak periods, customs or a carrier delay can extend it. The exact amount, in your currency, is worked out in the cart once your address is entered.
The timer is sent as a parcel of about 1.2 kg from a distributor's warehouse in France. The exact shipping cost is shown in the basket.
Frequently asked questions
10 questions
6 key questions, 10 in the detailed view
You may also like
Let us talk about your project
A question about this product or your setup? Our team will answer and advise you.
Interest-free instalment payments
Offered depending on the cart amount, at checkout.
Delivery in 2 to 15 working days
Depending on the products and shipping sites. Estimate by destination in the estimator on this page.
After-sales service 7 days a week by email or chat
Our team answers all your questions.
Shop responsibly
Become part of the change.