Ultrasonic humidifier, 5 L, 400 ml/h
This RAM ultrasonic humidifier diffuses a cool mist of 400 ml per hour from a 5 litre tank, through an adjustable nozzle. Controlled by a simple dial, it suits small spaces, such as a grow tent, a shelf of seedlings or a corner for rooting cuttings, where humidity needs to rise by a few points.
The summary
- What you receive: a RAM ultrasonic humidifier with a 5 L tank.
- Its output: 400 ml/h, or about twelve hours at most per tank.
- Its place in aquaponics: the seedling station, not the greenhouse where the air is already humid.
- Filling: reverse osmosis, distilled or rain water, never the fish water.
Cold mist for a small grow tent, seedling shelf or cuttings corner
Small growing spaces do not need a large unit: gaining 10 or 15 points of humidity is often enough to stop your young plants drying out. The 5-litre RAM ultrasonic humidifier meets this need. A vibrating disc breaks the water into cold mist, pushed out by an adjustable nozzle, at 400 ml per hour on the maximum setting, which makes it a unit well suited to a compact tent, a seedling shelf or a cuttings corner.
💧 A unit for small volumes
The ultrasonic principle explains both the appliance's low running cost and its requirements. The disc vibrates at a frequency too high for the ear and tears very fine droplets from the water's surface, which the airflow from the nozzle disperses into the room. Nothing heats up, which is why the humidifier uses 30 W and the mist comes out cold, with no risk of burning the leaves or your hands. With 400 ml/h, a full tank lasts about 12 hours at full power, and longer when the dial reduces the output. Aim the nozzle towards the top of the tent rather than at the leaves, so that the mist evaporates before falling back down, and place your unit up high, on a shelf or a stool.
A dial
The flow rate is adjusted by hand, from a light mist up to the maximum flow rate of 400 ml/h.
A thermo-hygrometer
Placed near the plants, it shows whether the chosen setting holds the desired value.
A timer
It runs the humidifier at the same hours as the lighting.
Demineralised water
Be it reverse-osmosis, distilled or rainwater, it prevents limescale from building up on the disc.
🌱 In aquaponics, at the seedling station
In aquaponics, the humidifier belongs at the seedling station rather than in the greenhouse that houses the grow beds. Lettuces, herbs and tomatoes intended for the system germinate better in humid air, around 60 to 70% during vegetative growth, than in the dry air of a heated room in winter. The FAO guide advises raising plants in a nursery and only transferring them to the grow bed at least 2 weeks after the first leaves appear. Combined with a daily timer and the guide to setting up an indoor seedling area, the humidifier holds this level throughout that phase. Above the grow beds, by contrast, the water that evaporates already humidifies the air, and a top-up would mainly risk encouraging foliar diseases.
A probe at plant level to set the dial
With no built-in setpoint, the humidifier is adjusted according to a reading taken where your plants grow, not at eye level. The digital thermo-hygrometer with probe places its sensor right at the level of the seedling trays while the screen stays readable from outside the tent. You can then see at a glance whether the dial position is holding the value you want, and you correct the setting before the young leaves suffer from dry air or excess humidity.
Hard water that wears out the pad
Ultrasonic humidifiers disperse the minerals in tap water into the air, where they settle as white dust on surfaces and build up on the disc, which reduces the output. Fill the tank with reverse osmosis, distilled or rain water, and avoid spring or mineral waters, which are not demineralised. Empty the unit between refills and never let it run dry.
🔧 Setting up and maintenance
Getting started takes just two steps. Fill the tank to the level you want, switch the unit on, then turn the dial to your chosen setting. The operating instructions for this humidifier ask you not to run it at the maximum setting for long periods and never to block the mist outlet. So start at the halfway mark and increase only if your thermo-hygrometer shows that humidity is still too low, which also spares the disc. A simple thermo-hygrometer is enough on an open seedling shelf.
Maintenance matters as much as the settings, because water that stagnates in a tank encourages the growth of micro-organisms. The US Environmental Protection Agency recommends, for portable humidifiers, emptying the tank, wiping all surfaces and refilling it every day, then giving it a full clean every 3 days. Rinse with clean water, wipe the disc with a damp cloth without scratching it, and leave to dry before refilling. A clean tank gives you an odour-free mist and a steady flow rate from one seedling season to the next.
This maintenance routine also protects against a risk that health authorities associate with humidifiers: legionella, a bacterium that thrives in stagnant, scaled water between 25 and 45 °C. Legionnaires' disease is contracted by breathing in fine droplets of contaminated water, never by drinking the water, and it does not pass from one person to another. A 5-litre tank that runs for 12 hours almost empties itself every day; the danger comes rather from a unit put away full between two seedling seasons, or left for a week without running on a heated shelf. So empty it every day and before every shutdown, descale the pad as soon as it turns white, and always start again with fresh water, preferably demineralised.
The wiring deserves the same care, since the mist circulates next to the light bars, the heat mat and their sockets. Connect the appliance to an earthed socket protected by a 30 mA RCD, the protection that the FAO manual calls for wherever water meets electricity. If you use a timer, choose a model designed for indoor use, such as the 16 A digital weekly timer, fixed to the wall rather than left on the floor. Leave the cable with a loop lower than the socket, and unplug the humidifier before lifting the tank to fill it.
📏 A tent, a shelf, one night
In a grow tent, the extractor fan carries away, every minute, part of the humid air that the unit has just produced. If the humidity in your tent will not hold, first reduce the extraction speed during the lighting hours before turning the dial up to maximum. On an open seedling shelf, a clear lid placed over the trays keeps the humidity around your seedlings and limits the volume of air to be humidified. At night, when the temperature drops, the air approaches saturation, and humidity above 93% for 8 to 12 hours is enough for botrytis, grey mould, to infect the foliage. The timer therefore switches the unit off at the same time as the lighting.
You receive the humidifier ready to plug in, with its 5-litre tank. Place it on a stable, dry surface, away from sockets and electrical appliances, and sheltered from splashes. At the end of the season, empty it, clean it, let the tank dry with the lid open, then store the appliance somewhere dry until the next seedling season, so that limescale and deposits do not build up on the disc during the months of inactivity.
Technical specifications
Humidification
- Technology
- Ultrasonic, cool mist
- Flow rate
- 400 ml/hAdjustable with a dial
- Sump tank
- 5 LAround 12 h at maximum flow rate
- Adjustment
- Analogue dial, adjustable nozzleStart at the halfway point
The unit and its maintenance
- Power
- 30 W
- Dimensions
- 23 x 19 x 32 cm
- Recommended water
- Reverse osmosis, distilled or rainwaterHard water leaves a white dust
- Maintenance
- Empty every day, clean every 3 daysStagnant water encourages micro-organisms
In the box
- 1 RAM ultrasonic humidifier with its 5 L tank
Manufacturer's and distributors' values, run time calculated at maximum flow rate. Hygiene based on the EPA and regional health agencies, botrytis based on the University of Connecticut.
Manufacturer and product safety
- Manufacturer
- RAM
Information provided under Regulation (EU) 2023/988 on general product safety.
Estimate your
delivery time
Your estimate
It covers preparing your order and then the transit time quoted by the carrier, counted in working days.
It is not a guaranteed delivery date: public holidays, peak periods, customs or a carrier delay can extend it. The exact amount, in your currency, is worked out in the cart once your address is entered.
The humidifier is sent in its original box from a distributor's warehouse in France. The exact shipping cost is shown in the basket.
Frequently asked questions
8 questions
6 key questions, 8 in the detailed view
You may also like
Let us talk about your project
A question about this product or your setup? Our team will answer and advise you.
Interest-free instalment payments
Offered depending on the cart amount, at checkout.
Delivery in 2 to 15 working days
Depending on the products and shipping sites. Estimate by destination in the estimator on this page.
After-sales service 7 days a week by email or chat
Our team answers all your questions.
Shop responsibly
Become part of the change.










