Ultrasonic humidifier, 4 or 8 L tank
| Sump tank | Price | Price per L | vs 4 L |
|---|---|---|---|
| 4 L | $45.00 | $11.25 | — |
| 8 L | $56.00 | $7.00 | −38 % |
This Pure Factory ultrasonic humidifier puts out an adjustable cool mist, set with a dial, from a 4 or 8 litre tank. It raises the humidity of a seedling station, a cutting shelf or a small grow tent.
The summary
- What you receive: a Pure Factory ultrasonic humidifier, with a 4 or 8 L tank.
- The flow rate of the 4 L: from 250 to 380 ml/h, adjustable, for 7 to 12 hours of running time.
- Choosing the tank: 8 L to refill less often, 4 L for a compact growing corner.
- Control: with the dial, or via a humidistat socket plugged in upstream.
- In aquaponics: it serves the heated room where the system's seedlings sprout and its cuttings take root, using demineralised water and never the water from the fish.
- Maintenance: a tank emptied every day and thoroughly cleaned every 3 days.
Adjustable cool mist for a seedling station or a small grow tent
An ultrasonic humidifier does not heat the water: a disc at the bottom of the unit vibrates at an inaudible frequency and breaks the water into very fine droplets, which a small fan pushes out of the nozzle as a cool mist. The Pure Factory model applies this principle with a flow rate adjustable by dial, and it comes with two tank sizes: 4 litres in a compact format, or 8 litres to space out refills. You place it near a shelf of seedlings, a tray of cuttings or inside a small grow tent, with the nozzle pointing upwards.
The 4-litre version emits 250 to 380 ml of water per hour depending on the setting, for a power consumption of 30 W. At this flow rate, its tank lasts from 7 hours at the highest setting to 12 hours at the gentlest, which is a whole night or a working day. The 8-litre version doubles the water reserve and delivers up to 300 ml per hour, or about 26 hours of running at the maximum setting, which lets you space out refills in a very dry room. It switches itself off when its tank is empty, and an indicator light tells you it needs filling. It is filled from the top, without turning the tank over, and the adjustable nozzle directs the mist wherever you want it.
Seedling shelf
The mist keeps the air humid above the trays during germination.
Cuttings
The leaves stay turgid while the roots form.
Small tent
The 4 L is enough for a closed indoor growing space.
Heated room
The 8 L model compensates for the dry air from a radiator for longer.
🌫️ The dry air of a heated room
Relative humidity expresses the amount of vapour the air contains, compared with what it could hold at its temperature. Warm air holds far more water than cold air: according to the University of Massachusetts, its capacity doubles each time the temperature rises by about 11 °C. When a radiator warms winter air without adding any water to it, its relative humidity drops accordingly, and young leaves lose their water faster than a developing root system can replace it. The humidifier's mist returns some of this vapour to the air, which you measure at tray level.
A humidistat socket to cut the mist
The humidifier diffuses for as long as it is switched on. Placed behind a humidistat socket set to humidification, it stops at the set point and starts again when the air dries out. A digital thermometer and hygrometer placed at tray level then tells you whether the set point holds where the plants are growing.
Saturated air encourages damping off in seedlings
Too much humidity does as much harm as air that is too dry: cool, damp air encourages the fungi responsible for damping off in seedlings, and the vapour condenses on the coldest surfaces, leaves included. Please also do not add essential oil, fragrance or any other product to the sump tank, which should only ever receive clean water.
The mist should not fall directly onto the trays. Point the nozzle towards the top of the room, away from the plants, so that the droplets evaporate before they touch a leaf or the compost. A small fan placed at plant height and run a few times a day for 5 to 10 minutes then circulates the air, strengthens the stems and limits fungal growth, as Utah State University advises for indoor seedlings. This gives you humid air without standing water on the foliage.
🌱 Seedlings and cuttings, two different needs
Your needs change as the seedlings emerge. During germination, a dome or a regulated mist keeps humidity around the seeds, but Utah State University advises removing the dome once about half the seeds have germinated, then letting the grow medium dry out moderately between waterings, so as not to deprive the roots of oxygen. Your cuttings, which do not yet have roots, benefit for longer from humid air, which limits water loss from their leaves. If you use an Hydrocloner cloning unit placed in the same room, it benefits from this mist. Finally, the University of Massachusetts reminds us that foliage should stay dry from dusk to dawn: a daily timer switches off the humidifier at night.
🐟 In aquaponics
An aquaponic greenhouse is rarely dry, because the water in the tanks evaporates continuously: monitoring of a small raft system by Johns Hopkins University measured a loss of about 1% of its volume per day, or 3 L for a 300 L pond. The concern there is rather to stay below the 80 to 85% relative humidity above which foliage diseases take hold, and a humidifier has no place in it. Your young plants intended for the system, on the other hand, are often started in a heated room of the house, where the controlled mist replaces the humidity of the greenhouse. Once sprouted in germination sponges, they then join the grow beds with their plug, and the guide to setting up your indoor seedling area helps you organise this corner of the house.
🧽 Maintenance
Stagnant water in a warm tank quickly turns cloudy, so you should empty the tank every day rather than topping it up, and clean it thoroughly every 3 days, with the appliance unplugged, before filling it with fresh water from the top. Low-limescale water, whether reverse-osmosis or demineralised, limits the white dust that the ultrasound disperses around the appliance, since the dissolved minerals leave with the mist. If a white deposit nonetheless forms on the disc, descaling with diluted white vinegar, followed by a careful rinse, restores its efficiency. Store the appliance empty and dry at the end of the seedling season.
This regular rinsing has a health reason as much as a practical one. Regional health agencies list humidifiers among the installations that can spread legionella when their water stagnates and scales up between 25 and 45 °C, and Legionnaires' disease is caught precisely by breathing in droplets of contaminated water, never by drinking it. The US Environmental Protection Agency, for its part, advises emptying, wiping and refilling a portable humidifier with fresh water every day, then cleaning it thoroughly every 3 days. An 8-litre tank that lasts more than a day tempts you to top it up without emptying it: that is precisely the habit to avoid, especially in a heated room.
On the electrical side, the unit produces a mist a few tens of centimetres from the lamps, the germination heat mat and their sockets. Plug it into an earthed socket protected by a 30 mA residual current device, as the FAO manual requires wherever water and electricity are close together, and keep the plugs higher than the unit, out of the path of the mist. Leave each lead with a loop lower than the socket, so that water running down the cable drips onto the floor. Unplug the humidifier before removing the water reservoir, since the disc sits in the water and stays live.
Technical specifications
The two versions
- Sump tank
- 4 or 8 L
- Filling
- From the top
- Flow rate of the 8 L
- Up to 300 ml/hAbout 26 h at the maximum setting
- 8 L safety features
- Shut-off and empty sump tank indicator light
The 4 L model
- Flow rate
- 250 to 380 ml/hAdjustable with a dial
- Battery life
- 7 to 12 hDepending on the flow rate chosen
- Power
- 30 W
- Feeding
- 220 to 240 V, 50/60 Hz
The device
- Technology
- Ultrasonic, cool mist
- Nozzle
- Adjustable
- Adjustment
- Dial, no built-in humidistat
- Recommended water
- Low-limescale, reverse osmosis or demineralised
To allow for in addition
- Automatic control
- Hygrostat with probe
- Humidity measurement
- Digital thermo-hygrometer
6 further specifications are available in the detailed view.
In the box
- 1 Pure Factory ultrasonic humidifier with its 4 or 8 L sump tank
Values from the manufacturer and its distributors, run times calculated from the flow rate. Seedling benchmarks from the Universities of Utah and Massachusetts, hygiene from the EPA and the regional health agencies.
Manufacturer and product safety
- Manufacturer
- The Pure Factory
- Website
- www.thepurefactory.com
Information provided under Regulation (EU) 2023/988 on general product safety.
Estimate your
delivery time
Your estimate
It covers preparing your order and then the transit time quoted by the carrier, counted in working days.
It is not a guaranteed delivery date: public holidays, peak periods, customs or a carrier delay can extend it. The exact amount, in your currency, is worked out in the cart once your address is entered.
The humidifier is sent in its box from a distributor's warehouse in France. The exact shipping cost is shown in your basket.
Frequently asked questions
8 questions
6 key questions, 8 in the detailed view
You may also like
Let us talk about your project
A question about this product or your setup? Our team will answer and advise you.
Interest-free instalment payments
Offered depending on the cart amount, at checkout.
Delivery in 2 to 15 working days
Depending on the products and shipping sites. Estimate by destination in the estimator on this page.
After-sales service 7 days a week by email or chat
Our team answers all your questions.
Shop responsibly
Become part of the change.









