CO2, temperature and humidity monitor with display
This CO2 monitor shows on a single screen the carbon dioxide level of the air, to within 50 ppm, the temperature and the relative humidity. An indicator light warns you when CO2 exceeds the recommended level, which helps you judge the ventilation of a closed greenhouse, a grow room or a seedling room.
The summary
- What you receive: a monitor with an LCD screen that displays CO2, temperature and relative humidity together.
- What it measures: CO2 to within 50 ppm, temperature from -10 to 50 °C and humidity from 0 to 100%.
- In an aquaponic greenhouse: it flags nights that are too humid above the beds and CO2 depleted in the middle of the day, without measuring the CO2 dissolved in the fish water.
- The right benchmark: around 425 ppm of CO2 in open air, and ventilation as soon as the greenhouse drops well below that.
- The alert: an indicator light comes on when CO2 exceeds the level recommended for indoor air.
- What it does not do on its own: it measures and warns, while ventilation is controlled by hand or by a timer.
Three readings on one screen to judge the ventilation of a closed greenhouse or grow room
In a closed greenhouse or a grow room, the composition of the air changes through the day: plants take up carbon dioxide in the light, while their respiration at night, like that of the people working there, gives it off. This LCD monitor displays the CO2 level continuously, with an accuracy of 50 ppm, alongside the temperature and relative humidity. That way you can read the three values that decide when to ventilate, with no calculation or prior setup.
🌿 CO2, the raw material of plants
Photosynthesis turns the CO2 in the air into sugars, and it slows down when the air is depleted of it. Outdoors, the level is around 425 ppm, a little over 0.04% of the air. In a sealed greenhouse, closed in cold weather, it can drop to 150 or 200 ppm during the day, because the plants absorb more CO2 than the air supplies to them. Growth then slows without any visible symptom on the leaves, which makes measuring all the more useful.
The monitor shows you this drop as it happens. When the displayed value falls clearly below that of the outside air in the middle of the day, opening the vents, even briefly, is enough to restore the level, because the outside air replaces that of the greenhouse within a few minutes. Professional growers go further and enrich the air to between 700 and 1,000 ppm to speed up growth, a practice that requires a CO2 source and a controller. In a small greenhouse, well-placed ventilation remains the action that counts, and it is the one the monitor helps you decide on.
🐟 In an aquaponic greenhouse
An aquaponic greenhouse contains a large expanse of water, that of the fish tank and the grow beds, which evaporates day and night. Relative humidity therefore rises quickly as soon as the vents stay closed, especially in the evening, when the air cools and can no longer hold as much vapour. Yet grey mould, caused by the Botrytis fungus, takes hold on foliage that stays wet for 8 to 12 hours, at a humidity of 93% or more and between 13 and 18 °C. Reading humidity and temperature together shows you these at-risk nights before the leaves become covered in condensation, and the guide to protecting your aquaponic system in winter details ventilation in the cold season.
Ventilate at fixed times using a timer
If your greenhouse has an extractor or a fan, the daily timer starts it every evening after sunset and every morning around sunrise, at the times when humidity is at its highest. The monitor then lets you check, over the first few days, that these time slots really do bring the displayed humidity down. You then adjust their duration according to what you read, rather than guessing with the seasons.
Keep the monitor away from splashes
An electronic device plugged into the mains must never be placed at the edge of a fish tank or under a dripping pipe. Fix it to an upright of the greenhouse, away from splashes and from the condensation that runs down the walls. Unplug it before moving it near water.
The same reading guides daytime ventilation, when the sun heats the greenhouse and the plants consume the most CO2. Opening up in early afternoon replaces the depleted air and lowers the temperature under the roof, while the water in the tanks, whose temperature changes far more slowly than that of the air, stays stable for the fish. This approach suits salads, herbs and tomatoes grown on clay pebbles or on a raft, and it limits foliage diseases without any treatment, which matters in water shared with fish. The guide on heating your greenhouse in winter shows how to reconcile this ventilation with keeping the temperature up.
📍 Placement and everyday reading
Place the monitor at leaf height, where plants actually draw their CO2, and always in the shade: a direct ray of sunshine on the casing skews the displayed temperature by several degrees. Keep it away from an air vent, which only reflects the incoming air, and from where you work, because your own breath raises the CO2 reading whenever you lean over it. Three readings a day are enough to get to know your greenhouse: in the morning before opening up, in the early afternoon and in the evening, and a few days of observation will teach you at what time the CO2 level drops and when humidity becomes critical.
In a grow room fitted with lamps, the principle is the same, with one extra constraint: the air is only renewed if you keep it moving. A duct fan combined with a fresh air intake, and controlled where needed by a temperature and humidity ventilation controller, keeps the CO2 level close to that of the outside air and removes the moisture given off by the plants. When the air stays humid despite ventilation, in a basement for instance, a compressor dehumidifier takes over, and the monitor tells you which of the two to act on first.
Before relying on the figures, check your monitor once outdoors or in front of a wide-open window. After 15 to 30 minutes of stabilisation, it should display a value close to that of the outside air, which public guidelines put between 400 and 500 ppm depending on location. A reading far outside this range indicates a sensor that has not yet reached the ambient temperature, or a sensor that is drifting, which should be reported to customer service before you rely on its measurements. Repeat this check from time to time, for example at each change of season, as it is the simplest way of knowing whether the difference you read in the greenhouse is genuine.
The choice of location matters as much as the accuracy of the device. Public guidance for CO2 sensors says to place them in the area where the air is actually breathed, away from an open door or window, and not to breathe out near them. In a greenhouse, that means fixing it in the middle of the crops, at leaf height, rather than at the entrance or against an opening vent. Do not put it above a tray either, where humidity and splashes rise, and keep its power supply dry, plugged into a socket protected by a 30 mA residual current device.
🔌 Setting up
The monitor plugs in and shows its three readings straight away, with no configuration or calibration needed on arrival. A built-in indicator light comes on when the CO2 level exceeds the recommended level for indoor air, so you are alerted even when you are not looking at the screen. Give it a few minutes after each move so that its sensors adjust to the room temperature before you take a reading, then compare your first reading with the outdoor air to give yourself a point of reference.
Technical specifications
Measurements
- CO2
- Accuracy of ± 50 ppmHumidity of the air, not that of the water in the tanks
- Temperature
- -10 to 50 °CRead it in the shade, as direct sun skews the value
- Relative humidity
- 0 to 100%
- Alert
- CO2 overshoot indicator lightLights up when the recommended indoor air level is exceeded
The device
- Display
- LCD screen, three simultaneous readings
- Getting started
- Plug in, instant readingNo adjustment or calibration needed on delivery
- Uses
- Greenhouse, grow room, seedlings, indoors
- Control
- Measurement and alert onlyVentilation is controlled separately, by hand or with a timer
In the box
- 1 CO2, temperature and humidity monitor with an LCD screen
Values from the monitor's distribution data sheet. Greenhouse CO2 benchmarks based on Oklahoma State University and NOAA, botrytis based on the University of Connecticut, indoor threshold based on the HCSP.
Estimate your
delivery time
Your estimate
It covers preparing your order and then the transit time quoted by the carrier, counted in working days.
It is not a guaranteed delivery date: public holidays, peak periods, customs or a carrier delay can extend it. The exact amount, in your currency, is worked out in the cart once your address is entered.
The monitor ships as a small parcel from a distributor's warehouse in France. The exact shipping cost is shown in your basket.
Frequently asked questions
8 questions
6 key questions, 8 in the detailed view
You may also like
Let us talk about your project
A question about this product or your setup? Our team will answer and advise you.
Interest-free instalment payments
Offered depending on the cart amount, at checkout.
Delivery in 2 to 15 working days
Depending on the products and shipping sites. Estimate by destination in the estimator on this page.
After-sales service 7 days a week by email or chat
Our team answers all your questions.
Shop responsibly
Become part of the change.