Total dynamic head, explained simply
The total dynamic head, or TDH, is the height the pump actually has to overcome. It adds up two things. First the static head, the difference in level between the water surface where the pump draws and the point where the water comes out. Then the head losses, what the water loses through friction in the pipes, bends, valves and fittings, counted as extra metres of height. The University of Florida guide and the FAO hydraulics chapter for aquaculture describe this same total.
One point often catches people out. For a submersible pump, the height is measured from the surface of the tank water, not from the bottom where it rests. A pump sitting at 60 cm depth, sending water to a bed whose inlet is 90 cm above the surface, has 0.9 m of static head to overcome, not 1.5 m. Depth only matters for the manufacturer's immersion limit.
Head losses grow with the flow rate and with every obstacle along the route. The Florida guide gives a telling example, as a single 2-inch PVC elbow slows the water as much as about 1.6 m of extra straight pipe. On a small installation, the simplest approach is still to think in terms of flow rate lost per fitting, using the FAO rule of thumb.