Replacement pH probe with BNC connector

Regular price Dhs. 369.00
Regular price Sale price Dhs. 369.00
Dhs. 123.00 × 3 with no fees

This double-junction pH probe replaces the one on a Bluelab Guardian monitor or on any Bluelab device with a BNC connector. It measures from 0 to 14 pH to within ±0.1 pH, on the end of a 2 m cable, and connects with a quarter turn on the plug, before a two-point calibration.

Ref. 500615-2-1-2·Electronic tester
Customer support 7 days a week by email
Delivery within 2 to 15 business days
100 % secure payment
Visa Mastercard American Express PayPalCartes Bancaires Apple Pay Shop Pay Bancontact EPS KlarnaMobilePayGoogle Pay BizumSatispay

The summary

  • What you receive: the probe with its 2 m cable, a suction-cup holder and a cap filled with KCl.
  • Compatibility: any Bluelab meter, monitor or controller fitted with a BNC socket.
  • What it measures: pH from 0 to 14, to within ±0.1 pH at 25 °C.
  • Setting up: a quarter turn on the BNC plug, then a two-point calibration.
  • In aquaponics: continuous monitoring of the fish water pH, with the probe placed after the filter.
  • Maintenance: a tip that is always kept wet and a calibration every month.

Double-junction pH electrode for the Guardian monitor and Bluelab devices

This Bluelab pH probe replaces the one on your Bluelab Guardian permanent monitor or your Bluelab device with a BNC connector. It connects at the end of a 2 m cable, sits in the sump tank and measures pH from 0 to 14, with an accuracy of ±0.1 pH at 25 °C. Like any pH electrode, the original probe ages with use and eventually responds slowly or can no longer be calibrated: it is then the probe, not the device, that needs replacing, which restores your monitor to its original accuracy.

🔬 A double gel junction

The measurement originates in a glass bulb sensitive to hydrogen ions, constantly compared with a silver/silver chloride reference electrode bathed in a saturated potassium chloride gel. The double junction places two successive barriers between this reference and the water being measured, which slows its contamination by the salts in the nutrient solution and extends the life of the probe. The gel cannot be refilled, so you have no electrolyte to top up, and the polycarbonate body protects the inner glass tube from everyday knocks.

The probe works between 0 and 60 °C, a range that also applies to its storage, and it requires water with a conductivity of at least 0.2 EC. A nutrient solution or aquaponic system water sits above this threshold, whereas osmosis water, almost free of salts, sits below it and does not allow a reliable reading. The watertight seal between the cable and the probe body lets it stay continuously submerged in your sump tank.

🔌 Commissioning

Line up the lugs on the BNC connector with those on your meter, then push and turn a quarter turn to lock it. To remove the storage cap, first loosen its base by one turn, then slide it gently off the tip. Next, calibrate the probe at two points, at pH 7.0 and then at pH 4.0 if your readings are below 7, or at pH 10.0 if they are above. Finally, the suction-cup holder supplied keeps the probe against the wall of your sump tank, with the tip submerged by at least 2 cm, which prevents unstable readings.

The tip must never dry out

A pH probe whose tip dries out can be permanently damaged. Each time you take it out of the water, put its cap back on, filled with potassium chloride storage solution, enough to cover the tip. Never use reverse osmosis, distilled or demineralised water to rinse or store it, as pure water alters the chemistry of the reference and kills the probe.

pH 7 and pH 4 buffer solutions for the first measurement

A new probe must be calibrated before its first reading, then every month. The JBL ProFlora pH calibration kit, pH 7 and pH 4 buffers supplies the two values this two-point calibration requires, for solutions that stay below pH 7. Your monitor will then show accurate readings from the moment it is installed, without waiting for another order.

🌱 In aquaponics

In an aquaponic system, a fixed probe on a Guardian monitor shows you the pH at any hour, which matters because nitrification acidifies the water continuously and the target range leaves little margin. The FAO advises keeping the pH between 6 and 7; New Mexico State University (circular NMSU CR680) puts 6.8 to 7.0 forward as the best compromise between fish, plants and bacteria, and points out that nitrification almost stops below pH 6. The curve recorded by the monitor thus reveals the slow downward drift that a weekly measurement lets slip by. Place the probe in clear water, downstream of the mechanical filter, because oils, proteins and suspended matter form a film on the glass that slows the reading. Keep it away, too, from the spot where you pour in a pH corrector, so that it measures the system's water and not the dose you have just added.

pH cannot be read in isolation: it depends on alkalinity, the reserve of carbonates that buffers the acidity produced by the bacteria. The same NMSU circular recommends keeping it above 100 mg/L expressed as calcium carbonate, and raising the pH by alternating calcium hydroxide and potassium hydroxide, which also supply two elements often lacking in fish water. A NH4, NO2, NO3, pH and KH test pack is therefore a useful complement to the probe: when the monitor's curve starts to fall faster, a KH test tells you whether the buffer is running out. Calibrate the probe at the temperature of the pond water, and rinse it in tap water after each filter clean. The article on pH regulation in aquaponics details the corrections that follow the measurement.

🧽 Maintenance and lifespan

After each use, rinse the tip under tap water. Before each calibration, swirl it gently in a small container of tap water with a little probe cleaner or mild washing-up liquid added, then rinse it thoroughly; stubborn deposits can be removed with a soft toothbrush, but never rub the glass with a cloth or knock it against the side of the container.

If the probe has not always been kept in its solution, or if it has dried out by accident, leave it to soak for at least 24 hours in the storage solution before calibrating it. A pH probe remains a wear part: when its reading no longer changes from one solution to another, or calibration fails despite cleaning, the glass has aged and the probe needs replacing. It carries a limited 6-month warranty.

🧊 Storing the probe out of season

A probe that is not used over the winter should be prepared as if for a long spell in a cupboard. Clean the tip, rinse it under the tap, then fill the cap with potassium chloride storage solution until the bulb is covered before screwing it back on. Store it somewhere that stays between 0 and 60 °C: a probe left in an unheated greenhouse or a garden shed will freeze, and frost cracks the glass or damages the reference. In spring, check that the cap still contains liquid, leave the probe to soak for a few hours if it has dried out, then calibrate it before putting it back in the sump tank. A probe calibration and maintenance solution covers both of these tasks.

Technical specifications

The probe

Measuring range
0.0 to 14.0 pH
Accuracy
±0.1 pH at 25 °C
Reference
Double junction, Ag/AgCl, KCl gelNon-refillable gel, no electrolyte to top up
Body
Polycarbonate, watertight cable glandCan stay submerged continuously
Temperature
0 to 60 °CBoth in use and in storage
Minimum conductivity
0.2 ECRO water does not give a reliable reading

Connection

Connector
Standard BNCQuarter-turn locking
Cable
2 mCannot be extended
Appliances
Bluelab with BNC connectorReaders, Guardian monitors, Combo devices, controllers
Reference
Bluelab PROBPH

Maintenance

Calibration
Monthly, in 2 stepspH 7, then pH 4 or pH 10
Warranty
6 months, limitedThe probe is a wear part

To allow for in addition

Calibration buffer solutions
pH 7 and pH 4For calibration before the first measurement
Storage solution
Potassium chloride, KClTo refill the cap after each use

6 further specifications are available in the detailed view.

In the box

  • 1 Bluelab pH probe with 2 m cable and BNC connector
  • 1 probe holder with suction cup
  • 1 storage cap filled with potassium chloride solution

Manufacturer's values (product sheet, probe maintenance guide and Bluelab warranty terms).

Manufacturer and product safety

Manufacturer
Bluelab Corporation

Information provided under Regulation (EU) 2023/988 on general product safety.

Documents & manuals

Probe maintenance guide, in English

Commissioning, calibration, cleaning, rehydration, specifications and troubleshooting for the probe.

PDF · 0,7 Mo

Download

Estimate your
delivery time

Shipped as a tracked parcel from the distributor's warehouse in France. Shipping costs appear in the basket, depending on your address.

Frequently asked questions

10 questions

6 key questions, 10 in the detailed view

You may also like

Let us talk about your project

A question about this product or your setup? Our team will answer and advise you.

Interest-free instalment payments

Offered depending on the cart amount, at checkout.

Delivery in 2 to 15 working days

Depending on the products and shipping sites. Estimate by destination in the estimator on this page.

After-sales service 7 days a week by email or chat

Our team answers all your questions.

Shop responsibly

Become part of the change.