Amtra non-return valve for 4/6 mm air pipe

Regular price Dhs. 21.00
Regular price Sale price Dhs. 21.00

This check valve fits on the air pipe, between the pump and the tank. It lets air through and stops water from flowing back down into the pump when it stops, during a power cut for example.

Ref. A800CV1-X2·Aeration accessory
Packaging : Pack of 2
100 % secure payment
Visa Mastercard American Express PayPalCartes Bancaires Apple Pay Shop Pay Bancontact EPS KlarnaMobilePayGoogle Pay BizumSatispay

The summary

  • What it does: it lets air through and blocks water flowing back towards the pump.
  • For which pipe: the standard 4/6 mm air line.
  • Where to fit it: on the line, between the pump and the tank, close to the pump.
  • Which pack: 2 valves for one pump, 4 for several tanks.

Small valve that protects the air pump from water flowing back when it stops

When your air pump stops, during a power cut for example, nothing pushes the water back along the pipe any more, and water from the tank can flow back to the pump by siphoning if the pump sits lower than the water level. The water then wets the diaphragm and can reach the electrical part of the pump. This Amtra non-return valve fits on the 4/6 mm air pipe: it lets air through to the tank and closes as soon as water flows back towards the pump.

🧭 Fitting it the right way round

The check valve has a direction of flow, and it only works in that direction. Cut the pipe at the chosen spot, preferably close to the pump and above the water level, then push each piece onto one of the connectors. Before putting the diffuser back in the tank, blow gently from the pump side: air should pass through, whereas it should stay blocked if you blow from the other side. If nothing passes, turn the valve round. Finally, check that the pipe is pushed firmly onto both of the 2 connectors, with no kinks, so that no air leak reduces the output of your air pump.

A non-return valve on every pipe to protect

If the air from the pump is shared between several diffusers, fit the check valve before the T or Y fitting, or put a check valve on each branch, so that every pipe is protected.

One pump, one diffuser

Fit the non-return valve on the pipe, close to the pump.

Quarantine tank

Its small booster pump also needs its non-return valve.

Several pumps

Each pump gets a non-return valve on its outlet.

A advance valve

The pack lets you keep one as a spare.

Check the oxygen after a power cut

A power cut stops the air pump, and the dissolved oxygen in the tank falls until aeration restarts, all the more quickly the warmer the water is. The liquid dissolved oxygen test tells you, once the power is back, whether the water has regained a sufficient level for your fish. You then know whether you need to boost aeration for a few hours or whether everything is back to normal.

🌱 In aquaponics

An aquaponic system often has several air pumps, one for the fish tank and one for a deep water culture grow bed. Each deserves its own check valve, because a power cut stops them all at the same time. If water flows back into a pump, you have to take it apart and dry it, and the tank is left without air in the meantime. The guide aquaponics and summer holidays points out that a power cut is the only genuinely dangerous scenario during an absence, and suggests a battery-powered backup aeration.

🔧 Maintenance and replacement

A check valve needs no adjustment, but its seal depends on a small moving part that eventually clogs. A deposit of limescale or dust can make it stick, so that air passes poorly, or stop it from closing again altogether. Repeat the blow test once or twice a year, when you clean the diffusers: if air passes in both directions (2 in total), or no longer passes at all, replace the valve. The pack of 4 leaves you with a spare so you can do it without delay.

Technical specifications

The essentials

Pipe
4/6 mm
Function
Prevents water backflow
Body
Clear
Reference
Amtra A800CV-1

Assembly

Location
Between the pump and the tank
Direction
Air inlet on the pump side

In the box

  • 2 or 4 non-return valves for 4/6 mm pipe, depending on the pack chosen

Pipe diameter, function and reference taken on 11/10/2026 from the Amtra manufacturer's data sheet.

Manufacturer and product safety

Manufacturer
CAMON&CROCI Pet Group S.p.A.
Postal address
Corso Italia 22, 20122 Milano (MI), Italie (siège légal) ; site opérationnel : Via S. Alessandro 8, 21040 Castronno (VA), Italie

Information provided under Regulation (EU) 2023/988 on general product safety.

Which kit for your setup?

The same valve in two quantities. What sets them apart is the number of pipes to protect.

2 or 4 valves? Three answers, and the table highlights the pack that suits you.

Non-return valvesTypical usePrice
Recommended
Pack of 2Your choice
2A pump and a spareDhs. 21.00
Pack of 4Your choice4Several pumps or several tanksDhs. 37.00
Pack of 2Recommended
What the set contains
Non-return valves2
Typical useA pump and a spare
Pack of 4
What the set contains
Non-return valves4
Typical useSeveral pumps or several tanks

Pack size and pipe diameter recorded on 11/10/2026 from the Amtra manufacturer's data sheet.

Estimate your
delivery time

Delivered to your home by Colissimo or Chronopost, as you prefer at checkout. The exact cost is shown in the basket, according to the total weight of your order.

Frequently asked questions

6 questions

6 key questions

You may also like

Let us talk about your project

A question about this product or your setup? Our team will answer and advise you.

Interest-free instalment payments

Offered depending on the cart amount, at checkout.

Delivery in 2 to 15 working days

Depending on the products and shipping sites. Estimate by destination in the estimator on this page.

After-sales service 7 days a week by email or chat

Our team answers all your questions.

Shop responsibly

Become part of the change.