Extraction controller with adjustable hysteresis, 12 A

Regular price $200.34
Regular price Sale price $200.34
$66.78 × 3 with no fees

The Cli-mate Controller 12A controls an extractor fan and an intake fan together according to the temperature read by its 5 m probe. Four dials set the target temperature, the minimum and maximum speeds and the hysteresis, for a closed greenhouse or a utility room up to a 12 A load.

Ref. TK-CLIMATE-12A·Climate controller
100 % secure payment
Visa Mastercard American Express PayPalCartes Bancaires Apple Pay Shop Pay Bancontact EPS KlarnaMobilePayGoogle Pay BizumSatispay

The summary

  • What you receive: the controller and its temperature probe on a 5 m cable.
  • What it controls: an extractor fan and an air intake fan, 12 A in total.
  • The settings: set point, minimum and maximum speeds, hysteresis from 0 to 7 °C.
  • Override mode: a switch runs the motors at full speed without touching the settings.

Control of an extractor fan and an air inlet by temperature, up to 12 A

An extractor fan wired directly runs at the same speed at every hour, whereas the heat in a closed greenhouse varies greatly between early morning and afternoon. The Controller 12A varies the speed of your ventilation according to the temperature read by a remote probe, and it controls the extractor and the air-intake fan together, within a limit of 12 A for both.

Efficient ventilation relies on two units working together: in your greenhouse, the extractor fan removes hot, humid air through the top, while the intake fan brings in fresh air, preferably low down and on the opposite side. The controller speeds them up and slows them down together, so that the volume of air extracted and the volume of air drawn in change at the same rate. This 12 A load represents about 2,760 W at 230 V for the two motors combined, enough to equip a grow room or a family-sized greenhouse with powerful motors.

🎛️ Four settings for a single curve

The four dials on the front panel together set how the speed responds to heat. The set point fixes the temperature you are aiming for. The minimum speed keeps the motors turning even when the air is cooler than the set point, so that the space stays ventilated. The maximum speed caps the speed, which limits noise and draughts. The hysteresis, adjustable from 0 to 7 °C in 1 °C steps, defines the margin above the set point over which the speed ramps up: with 3 °C, the motors reach full speed when the temperature exceeds the set point by 3 °C, and they accelerate gradually in between.

Check the actual temperature before adjusting

A setpoint should be chosen according to what the crops experience, not according to the temperature displayed in the house. The 360° digital thermometer and hygrometer, fixed by its suction cup at leaf height, displays temperature and humidity together, refreshed every 20 seconds. Readings noted at several times of the day show you when the greenhouse overheats and when the air becomes laden with moisture, which lets you place the setpoint, the hysteresis and the minimum speed where they really matter.

Setpoint

The temperature above which the ventilation speeds up.

Minimum speed

A minimum speed setting that renews the air at all hours.

Maximum speed

A ceiling that limits noise and draughts.

Hysteresis

From 0 to 7 °C, the range over which the speed increases.

Never exceed 12 A for the two motors combined

The 12 A limit applies to the extractor fan and the intake fan combined, and it must never be exceeded. Add up the current shown on the rating plate of each motor before connecting them, and plug the controller into an earthed socket protected by a 30 mA residual-current circuit breaker. The housing is rated IP44: it withstands splashes of water, but it should be fitted outside the greenhouse it regulates, away from watering and from running condensation.

A three-position switch completes the dials. The first makes the two fans run according to your settings, the second switches them off, the third runs them directly at full speed. This forced operation is for quickly clearing an overheated greenhouse, for example after an afternoon of sun with the doors left shut, without changing the setpoint or the hysteresis: you then go back to the programmed operation, and the curve you have built stays intact.

🐟 The ventilated aquaponic greenhouse

Inside an aquaponic greenhouse, ventilation protects both the plants and the fish. According to the FAO, the water in a system is best kept between 18 and 30 °C, and between 22 and 29 °C for warm-water fish and nitrifying bacteria. A greenhouse closed up in the sun quickly exceeds these values, and the water in the tanks eventually warms up in turn. Yet warmer water holds less dissolved oxygen, whereas New Mexico State University recommends keeping at least 5 mg/L. By speeding up extraction as soon as the air exceeds the set point, the controller limits this heating before it reaches the water in your tanks. The guide to maintaining your aquaponic system in summer details the other tasks of the hot season.

Humidity is the other concern, as the tanks and foliage release water vapour continuously. The University of Connecticut notes that grey mould, Botrytis, develops when humidity stays at 93% for 8 to 12 hours, and it advises ventilating at dusk and at dawn, when the air cools and takes on moisture. This controller measures temperature only: it is therefore the minimum speed you choose that provides this background air exchange during the cooler hours, when the target is not reached. The article on limiting pests in aquaponics complements these preventive measures.

📍 Positioning the probe and the housing

The probe measures the air around it, and its position decides the whole regulation. Place it at crop height, in the centre of the area to be ventilated, in the shade and away from the intake and extraction vents. In direct sun, it would read a temperature higher than that of the leaves and make the motors run too fast; stuck against the air inlet, it would measure the outside air rather than the air inside the greenhouse. Measure the length of its cable before fixing the box, so that it reaches the centre of the ventilated area while keeping the box close to a socket.

The unit measures 23 x 15 x 8.5 cm and weighs 1.2 kg. Mount it outside the space it regulates, since it gives off a little heat itself, in a utility room or on a sheltered wall, on a dry surface, out of the path of watering jets and away from walls where condensation runs down in the morning. The motor cables and the power cord are best routed down below the unit, so that a drop following the cable cannot run back up to the terminals.

⚡ Calculate the motor load

The current drawn by each motor is shown on its rating plate, in amps. When only the power is given, you obtain the current by dividing the watts by the voltage: a 230 W extractor draws about 1 A at 230 V, a 690 W motor about 3 A. You then add up the two units and keep a margin below 12 A, since starting a motor briefly draws more current than its steady running. For an extractor and an intake fan of similar power, the margin remains comfortable as long as each stays below 1,000 W, which is under 9 A for the two together. Connect only AC motors that can be controlled by voltage: a fan with an EC motor, which receives its setpoint through a control wire, cannot be controlled this way.

🗓️ Adjusting through the seasons

The summer and winter settings on your controller differ mainly in the minimum speed. In summer, a high maximum speed and a short hysteresis make the ventilation react quickly and strongly as soon as the sun heats the greenhouse. In winter, the incoming air is cold: a reduced minimum speed is enough to remove the humidity without chilling the beds, and a raised setpoint delays the speeding up. The guide to heating your greenhouse in winter explains how to balance heating, insulation and ventilation during the cold season.

🛡️ Protection, compliance and warranty

The housing carries an IP44 rating: it is protected against objects larger than 1 mm and against water splashed from any direction, which does not make it proof against running water or immersion. Its power supply circuit, like all circuits in a dwelling under standard NF C 15-100, must go through a 30 mA residual current device, which cuts the power if an earth leakage appears, for example after water ingress. Clean the controller with a dry cloth while it is unplugged, and never open its housing while it is live, since internal components may stay charged for a few moments after unplugging. A spare fuse is supplied: if it blows, it is almost always a sign of overload, and you must disconnect a motor before replacing it. The manufacturer declares the unit compliant with the European Low Voltage and Electromagnetic Compatibility directives, and guarantees it for 12 months after installation, except in the case of incorrect wiring or an opened housing.

Technical specifications

Regulation

Measured quantity
Air temperature
Controlled devices
1 extractor fan and 1 air intake fanSpeed shared by both
Settings
Setpoint, minimum speed, maximum speed
Hysteresis
0 to 7 °C, in steps of 1 °CTemperature difference over which the speed rises to its maximum
Probe
Remote, on a cable
Switch
3 positions: set, off, full speed

The device

Maximum load
12 A in totalAround 2,760 W at 230 V, with a 20% margin recommended
Feeding
230 V, 50 Hz
Setpoint range
5 to 55 °C
Protection
IP44Withstands splashes, not running water
Dimensions
23 x 15 x 8.5 cm
Weight
1.2 kg
Warranty
12 months after installation
Compliance
Low Voltage and EMC Directives

6 further specifications are available in the detailed view.

In the box

  • 1 Controller 12A with mounting plate
  • 1 remote temperature probe
  • 1 spare fuse

Manufacturer's values (instructions and data sheet), weight from the distributor. Greenhouse benchmarks from the FAO and the Universities of New Mexico and Connecticut.

Manufacturer and product safety

Manufacturer
Cli-mate

Information provided under Regulation (EU) 2023/988 on general product safety.

Which extraction setting do you need?

From hysteresis-based extraction settings to the controller that also manages lighting and heating.

This controller or another from the same range? This model controls heat with a hysteresis of 0 to 7 °C; the others add humidity, negative pressure or lighting.

All-in-one climate controller for lamps, air and humidityYour choiceRecommended
Extraction controller with adjustable hysteresis, 12 AYour choice
Temperature and humidity ventilation controller, 2 x 4 AYour choiceTemperature-based extraction controller, 2 outlets of 4 AYour choice
What it measures
Temperature onlyNoYesNoYes
Measures humidityYesNoYesNo
Controls humidity through ventilationNoNoYesNo
What it controls
Controls the lightingYesNoNoNo
Heater socketYesNoNoNo
Air controlA ventilation circuitExtraction and air intake at the same speedSeparate extraction and air intakeSeparate extraction and air intake
Current rating allowed for the ventilation (A)7 A12 A8 A8 A
Adjustable hysteresisNoYesNoNo
Adjustable negative pressureNoNoYesYes
Price$334.65$200.34$189.15$166.77
All-in-one climate controller for lamps, air and humidity
What it measures
Temperature onlyNo
Measures humidityYes
Controls humidity through ventilationNo
What it controls
Controls the lightingYes
Heater socketYes
Air controlA ventilation circuit
Current rating allowed for the ventilation (A)7 A
Adjustable hysteresisNo
Adjustable negative pressureNo
Extraction controller with adjustable hysteresis, 12 ARecommended
What it measures
Temperature onlyYes
Measures humidityNo
Controls humidity through ventilationNo
What it controls
Controls the lightingNo
Heater socketNo
Air controlExtraction and air intake at the same speed
Current rating allowed for the ventilation (A)12 A
Adjustable hysteresisYes
Adjustable negative pressureNo
Temperature and humidity ventilation controller, 2 x 4 A
What it measures
Temperature onlyNo
Measures humidityYes
Controls humidity through ventilationYes
What it controls
Controls the lightingNo
Heater socketNo
Air controlSeparate extraction and air intake
Current rating allowed for the ventilation (A)8 A
Adjustable hysteresisNo
Adjustable negative pressureYes
Temperature-based extraction controller, 2 outlets of 4 A
What it measures
Temperature onlyYes
Measures humidityNo
Controls humidity through ventilationNo
What it controls
Controls the lightingNo
Heater socketNo
Air controlSeparate extraction and air intake
Current rating allowed for the ventilation (A)8 A
Adjustable hysteresisNo
Adjustable negative pressureYes

Manufacturer's values (instructions and data sheets for the four models in the range).

Documents & manuals

Climate Controller manual

Setting the target temperature, speeds and hysteresis, wiring and safety, in six languages including French.

PDF · 1,8 Mo

Download

Estimate your
delivery time

The controller ships in its original box from a distributor's warehouse in France. The exact shipping cost is shown in the basket.

Frequently asked questions

10 questions

6 key questions, 10 in the detailed view

You may also like

Let us talk about your project

A question about this product or your setup? Our team will answer and advise you.

Interest-free instalment payments

Offered depending on the cart amount, at checkout.

Delivery in 2 to 15 working days

Depending on the products and shipping sites. Estimate by destination in the estimator on this page.

After-sales service 7 days a week by email or chat

Our team answers all your questions.

Shop responsibly

Become part of the change.