Temperature and humidity ventilation controller, 2 x 4 A
This Cli-mate climate controller separately controls an extractor fan and an air-intake fan, each up to 4 A, varying their speed according to the temperature and humidity read by its dual probe. It keeps the room under slight negative pressure and suits a closed greenhouse, a grow room or a seedling room.
The summary
- What you receive: a Cli-mate controller with two 4 A outputs and its dual temperature and humidity probe.
- What it controls: the speed of the extractor fan and the air inlet fan, smoothly and without sudden jumps.
- The set points: from 5 to 55 °C and from 20 to 100% relative humidity.
- In aquaponics: it removes humidity from a closed greenhouse without cutting off the air at night.
- Setting up: one probe at plant level, two fans, four dials.
- What you need: an extractor fan and an air inlet fan, each drawing no more than 4 A.
Extraction and air intake controlled by temperature and humidity, for a greenhouse or grow room
In your enclosed room, the air warms up under the lamps and becomes laden with moisture as the plants transpire. Extraction running flat out all the time dries the air and cools it too much, while extraction switched off lets condensation build up. The Cli-mate Twin Controller Humi looks for the happy medium: it continuously varies the speed of an extractor fan and an air intake fan according to what its dual probe measures, temperature and relative humidity at the same time.
🌬️ Two fans, two settings
The unit has two independent outputs of 4 A each, one for the extractor fan and the other for the air intake, giving about 920 W per output at 230 V. On its front panel, dials let you set the desired temperature, between 5 and 55 °C, and the humidity level not to be exceeded, between 20 and 100%. When the reading drifts from the target, the controller gradually speeds up both fans, then slows them once the air is back within the chosen range. The dials adjust in steps of 1 °C and 5% humidity.
Minimum speed
One dial per fan sets the minimum speed, so that the air never stops circulating.
Negative pressure
The air intake runs more slowly than the extraction, from 0 to 50%, and the room stays under slight negative pressure.
Three positions
Each output can be set to automatic, off or full speed, useful for ventilating all at once.
Wall mounting
A plate on the back serves as both a mounting and a heat sink.
Negative pressure has two benefits. Air enters through the intended opening, filtered or screened, rather than through every gap, and humid, odour-laden air does not escape into the next room. The minimum speeds, for their part, prevent the pumping effect of an extractor fan that starts and stops every two minutes. Finally, the probe sits at plant level, in the shade, away from the air inlet, so that you adjust the climate the leaves actually experience.
Motors controlled by voltage
The controller varies the voltage sent to the fans. Connect extractors and fans with AC motors that are compatible with a speed controller, up to a limit of 4 A per outlet, and never a device with an electronic motor driven by its own control. The IP44 splash-proof casing is fixed outside the space it regulates and plugged into a socket protected by a 30 mA residual current device.
A thermo-hygrometer to check the setpoint
A digital thermometer and hygrometer placed near the probe records the night's extremes. It shows whether the setpoint holds at first light, when the greenhouse cools and the relative humidity rises of its own accord, and tells you whether the extractor's minimum speed needs raising.
This continuous variation is what sets the Twin Controller Humi apart from a simple probe thermostat, which switches a device on and then off, all or nothing. With a thermostat, your extractor fan goes from zero to full flow rate, so the temperature swings around the set point and cold air comes in in gusts. The controller, by contrast, adjusts the flow rate to the measured difference: a slight overshoot produces a slight speed-up, and the air is renewed at a pace that follows the day instead of chopping it up.
💧 Humidity regulated by fresh air
The controller does not dry the air itself: it replaces the humid air in your space with air from outside. This exchange lowers the relative humidity as long as the incoming air holds less water vapour than the extracted air. That is almost always the case in winter, since cold outdoor air holds little water and its relative humidity drops sharply as soon as it warms up in the greenhouse. On a hot, muggy summer day the effect is weaker, because the outside air is itself laden with moisture, and ventilation then serves mainly to remove heat.
Night brings the opposite case to daytime. The amount of water in the air stays the same, but the temperature drops, and the relative humidity rises until condensation forms on the walls and on the leaves. This is the moment the minimum speed is for: set it high enough for the air to keep renewing gently, and choose a humidity setpoint that the controller can hold without drawing in icy air. If humidity stays high despite extraction at full speed, it is the volume of air being renewed that falls short, and a more powerful extractor fan becomes necessary.
🐟 In a closed aquaponic greenhouse
A greenhouse closed up in winter collects the water evaporated from the fish tank and the grow beds, and this vapour ends up on the glazing, the structure and the foliage, where standing water encourages botrytis and mildew. Connected to your extractor fan, the Twin Controller Humi renews the air as soon as humidity exceeds the set point, even if the temperature is fine, then returns to its minimum speed. In summer, it takes over when it gets hot. The guide to protecting your aquaponic system in winter details ventilation in the cold season.
Water temperature sets the limits of the adjustment here. An aquaponic system is run at roughly 18 to 29 °C for warm-water fish and 13 to 18 °C for trout, and warmer water holds less dissolved oxygen, whereas fish need at least 5 mg/L. In summer, a sensible temperature setpoint stops the tank from heating up under the glazing. In winter, every cubic metre extracted also carries away heat: pair the controller with a heater such as the Lighthouse greenhouse fan heater, and position the air intake away from the tank so that no cold air falls onto the water.
🔧 Commissioning step by step
First fix the base plate to the wall, outside the space to be regulated and out of the way of splashes, then place the probe at plant level, in the shade and away from the lamps as well as from the air inlet. Connect the extractor fan and the intake fan, each to the output reserved for it, then set both selectors to full speed to check the direction of airflow. Then switch back to automatic and set, in this order, the temperature, the maximum humidity, the two minimum speeds and the negative pressure. Finally, let it run for a full day, noting the extremes on a thermo-hygrometer, before fine-tuning your settings.
📦 The controller and its probe
The controller comes with its wall-mounting plate and its dual temperature and humidity probe. It plugs into a mains socket, then the extractor fan and the air-intake fan connect to its two side outputs, each reserved for its own role. The unit measures 19 x 13.5 x 8.5 cm, so you can easily fix it to a greenhouse post or to the wall of a utility room, next to the electrical panel.
⚡ Load, margin and protection
Each outlet takes 4 A, or about 920 W at 230 V, and the limit applies per outlet: the margin on one does not carry over to the other. A fan motor draws more than its running current at start-up, and it heats up more at low speed when it is voltage-controlled. So aim for devices that draw no more than 3.2 A each, which gives a 20% margin, and read the current rating from the nameplate rather than relying on the diameter of the sleeve. The controller plugs into an earthed wall socket, on a circuit protected by a 30 mA residual current device, as required by standard NF C 15-100 for all circuits in a dwelling. Its IP44 housing withstands splashing water, but not direct spraying or condensation running down a cold wall. The unit is declared compliant with the European Low Voltage and Electromagnetic Compatibility directives, with a 12-month warranty from the date of installation.
Technical specifications
Regulation
- Controlled parameters
- Temperature and relative humidity
- Temperature range
- 5 to 55 °C1 °C increments
- Humidity range
- 20 to 100% RH5% steps
- Negative pressure
- Adjustable from 0 to 50%
The device
- Outlets
- 2 x 4 A, extraction and air intakeAbout 920 W per outlet at 230 V
- Feeding
- 220 to 230 V, 50 Hz
- Protection
- IP44
- Dimensions
- 19 x 13.5 x 8.5 cm
- Warranty
- 12 months after installation
- Compliance
- Low Voltage and EMC Directives
The controls
- Minimum speed
- One dial per outlet
- Selectors
- Automatic, off, full speed
To allow for in addition
- Extractor
- Variable speed, 4 A at most
- Air intake fan
- Variable speed, 4 A at most
6 further specifications are available in the detailed view.
In the box
- 1 Cli-mate Twin Controller Humi 4 + 4 A controller with wall plate
- 1 dual temperature and humidity probe
Manufacturer's values (instructions and data sheet for the Humi model), output per outlet calculated at 230 V. Water benchmarks from New Mexico State University.
Manufacturer and product safety
- Manufacturer
- Cli-mate
Information provided under Regulation (EU) 2023/988 on general product safety.
Which controller for your humid greenhouse?
Four controllers from the same range, from heating alone to full climate control of a room.
| All-in-one climate controller for lamps, air and humidityYour choice | Extraction controller with adjustable hysteresis, 12 AYour choice | Recommended Temperature and humidity ventilation controller, 2 x 4 AYour choice | Temperature-based extraction controller, 2 outlets of 4 AYour choice | |
|---|---|---|---|---|
| What it measures | ||||
| Temperature only | No | Yes | No | Yes |
| Measures humidity | Yes | No | Yes | No |
| Controls humidity through ventilation | No | No | Yes | No |
| What it controls | ||||
| Controls the lighting | Yes | No | No | No |
| Heater socket | Yes | No | No | No |
| Air control | A ventilation circuit | Extraction and air intake at the same speed | Separate extraction and air intake | Separate extraction and air intake |
| Current rating allowed for the ventilation (A) | 7 A | 12 A | 8 A | 8 A |
| Adjustable hysteresis | No | Yes | No | No |
| Adjustable negative pressure | No | No | Yes | Yes |
| Price | $335.00 | $201.00 | $190.00 | $167.00 |
Manufacturer's values for the four controllers in the range.
Buying guide
Which controller for your humid greenhouse?
Documents & manuals
Twin Controller Humi manual
Setting of temperature, humidity, minimum speeds and negative pressure, in six languages including French.
Document not showing? Some publishers block display inside a frame, so open it in a tab.
Estimate your
delivery time
Your estimate
It covers preparing your order and then the transit time quoted by the carrier, counted in working days.
It is not a guaranteed delivery date: public holidays, peak periods, customs or a carrier delay can extend it. The exact amount, in your currency, is worked out in the cart once your address is entered.
The controller ships in its original box from a distributor's warehouse in France. The exact shipping cost is shown in the basket.
Frequently asked questions
10 questions
6 key questions, 10 in the detailed view
You may also like
Let us talk about your project
A question about this product or your setup? Our team will answer and advise you.
Interest-free instalment payments
Offered depending on the cart amount, at checkout.
Delivery in 2 to 15 working days
Depending on the products and shipping sites. Estimate by destination in the estimator on this page.
After-sales service 7 days a week by email or chat
Our team answers all your questions.
Shop responsibly
Become part of the change.