Temperature-based extraction controller, 2 outlets of 4 A
The Cli-mate Twin Controller separately controls an extractor fan and an air-intake fan of 4 A each, varying their speed according to temperature. Its dials set the target from 5 to 55 °C, the minimum speed of each fan and a negative pressure from 0 to 50%, for a closed greenhouse or a grow room.
The summary
- What you receive: a Cli-mate controller with two 4 A outputs, a temperature probe and a wall mounting plate.
- What it controls: the speed of the extractor fan and of the air intake fan, each according to temperature.
- The negative pressure: from 0 to 50% difference between the air intake and the extraction.
- In aquaponics: heat is expelled in summer without cold air dropping onto the tanks in winter.
- What to plug in: two variable-speed fans of 4 A at most, so around 900 W each.
- The settings: a set point of 5 to 55 °C and a minimum speed for each fan.
Two fans controlled by temperature, extracting air, for a closed greenhouse or grow room
The Twin Controller from Cli-mate answers a simple question: how fast should the extractor fan and the air intake fan run to hold the temperature you want? You set it between 5 and 55 °C, and the controller speeds up or slows down both fans, continuously according to what its probe measures, with a dial that adjusts in 1 °C steps. Each fan keeps its own 4 A output and its own settings, in a wall-mounted IP44-rated housing that suits grow rooms.
The setpoint
A dial sets the temperature to maintain, from 5 to 55 °C, adjustable in 1 °C steps.
Two speeds at minimum
Each fan keeps a minimum speed, so that the air never stops circulating.
Negative pressure
The air inlet runs more slowly than the extraction, and the room draws in fresh air through the opening provided.
Three positions per outlet
Each selector sets its output to automatic, off or full speed.
🌬️ Two independent outlets
A single controller driving two fans would make them run at the same speed, and air would come in as hard as it goes out. With two independent outputs, extraction keeps priority and the intake follows, slightly behind. This negative pressure draws fresh air in through the intended opening, filtered or screened, and stops warm, humid air from escaping through gaps into the next room. Separately set minimum speeds also allow you to keep a gentle flow of fresh air when the extraction is running slowly, and to avoid the repeated starting and stopping that wears out the motors.
Fans compatible with a speed controller
The unit adjusts speed by varying the voltage to the motors. Connect AC-motor extractor fans that are compatible with a speed controller, up to 4 A per output, which is roughly 920 W at 230 V, and never an electronically commutated motor driven by its own control. Mount the unit outside the space it regulates, on its plate that dissipates its heat, and plug it into an earthed socket protected by a 30 mA residual current device.
🐟 The aquaponic greenhouse, season by season
In a closed aquaponic greenhouse, the water in the tanks follows the air temperature, with a delay. Yet warmer water holds less dissolved oxygen, so cold-water fish are the first to suffer: the guidelines from New Mexico State University put their requirement at around 6.5 mg/L for trout, compared with about 5 mg/L for warm-water species. Set to a target a few degrees above the temperature wanted for the crops, the Twin Controller speeds up extraction from the warm hours onwards, removes the heat before it reaches the water, then returns the fans to their minimum speed in the evening, with no intervention needed.
Monitor humidity close to the crops
The Twin Controller regulates ventilation on temperature alone, whereas the tanks in an aquaponic greenhouse release vapour constantly. If you fit a digital thermometer and hygrometer at leaf height, you will see within a few days whether humidity follows temperature. When it stays above 80 to 85% despite the ventilation, a compressor dehumidifier usefully complements the controller.
Winter poses the opposite problem. The outside air is then too cold to blow directly onto the plants or onto the surface of the tanks, and the American greenhouse manufacturers' association recommends introducing it through small, well-distributed inlets, which mix it with the warm air before it reaches the crops. With the Twin Controller, you lower the minimum speed of the air intake to limit this cold flow, while still keeping enough air exchange to remove humidity. Point the air intake away from the fish tanks, so that the water does not lose heat through forced evaporation.
🔧 Sizing and wiring
Each outlet delivers 4 A, which corresponds to about 920 W at 230 V. Check the current rating on the plate of each fan before connecting it, and add the ratings together if you plug two units into the same outlet. Choose an air inlet with a diameter equal to or slightly smaller than that of the extraction, since the controller runs it more slowly anyway to create the negative pressure. If the air inlet passes through a filter or an insect screen, it loses flow rate, and the pressure difference will be reduced accordingly.
The probe measures the temperature the plants actually experience: place it at leaf height, in the shade, in the centre of the growing area, away from air vents, heaters and the control box itself. The controller runs on 220 to 230 V through a 1.30 m cable, and its wall plate keeps it clear of the wall so it can dissipate its own heat. If your greenhouse is fitted with a greenhouse thermostat with probe for heating, set its target a few degrees below that of the Twin Controller, so that the heating and the extraction never work against each other.
🎛️ Setting the target temperature
Start with a set point close to the temperature your crops need, then observe a sunny day and a night. If the extraction runs flat out too often, the set point is too low or the extractor is too small for the volume; if the greenhouse heats up without the fans reacting, move the probe closer to the heart of the crops. To ventilate quickly, after a treatment or in strong heat, lower the set point temporarily. Between two extraction cycles, small circulation fans running continuously even out the air: the University of Massachusetts recommends leaving them on all the time, except while the extractors are running.
⚡ A safe electrical installation
The enclosure is rated IP44: its side sockets and front panel withstand splashing water from any direction, but not the run-off from a wall covered in condensation, and certainly not a jet from a hose. In an aquaponic greenhouse, therefore, place it on the plant room side, and let only the probe and the motor cables enter the humid air, forming a loop beneath each entry point so that water drips off before reaching a socket. Each outlet takes 4 A, a limit that is not shared between the two: a 1,000 W extractor fan will not run on one outlet, even if the air inlet draws almost nothing. Allow a 20% margin for start-up, which means motors of 3.2 A at most. The power supply circuit must be protected by a 30 mA residual current device, and the enclosure must never be opened while live. Its declaration of conformity cites the European Low Voltage and Electromagnetic Compatibility directives, and the controller carries a 12-month warranty from installation.
Technical specifications
Regulation
- Controlled variable
- Air temperature
- Setpoint
- 5 to 55 °CDial adjustable in 1 °C steps
- Negative pressure
- 0 to 50 %
- Minimum speed
- Adjustable by fan
The device
- Outlets
- 2 x 4 A, one for the extractor fan and one for the air intakeThat is nearly 920 W each at 230 V
- Feeding
- 220 to 230 V, 50 Hz, 1.30 m cable
- Protection
- IP44
- Assembly
- Wall mounting plate included
- Selectors
- Automatic, off, full speed
- Compliance
- Low Voltage and EMC Directives
Usage guidelines
- Air inlet
- Diameter equal to or smaller than the extraction
- Probe
- At leaf height, in the shade
To allow for in addition
- Ventilation
- An extractor fan and an air inlet
- Control
- Thermometer and hygrometer
6 further specifications are available in the detailed view.
In the box
- 1 Cli-mate Twin Controller 4 + 4 A controller and its temperature probe
- 1 wall mounting plate
Values from the manufacturer (manual and Twin Controller data sheet), power per output calculated at 230 V. Greenhouse benchmarks from the University of New Mexico, the NGMA and the University of Massachusetts.
Manufacturer and product safety
- Manufacturer
- Cli-mate
Information provided under Regulation (EU) 2023/988 on general product safety.
Which fan speed controller should you choose?
Four controllers from the same range, from heat-controlled extraction to full climate control.
| All-in-one climate controller for lamps, air and humidityYour choice | Extraction controller with adjustable hysteresis, 12 AYour choice | Temperature and humidity ventilation controller, 2 x 4 AYour choice | Recommended Temperature-based extraction controller, 2 outlets of 4 AYour choice | |
|---|---|---|---|---|
| What it measures | ||||
| Temperature only | No | Yes | No | Yes |
| Measures humidity | Yes | No | Yes | No |
| Controls humidity through ventilation | No | No | Yes | No |
| What it controls | ||||
| Controls the lighting | Yes | No | No | No |
| Heater socket | Yes | No | No | No |
| Air control | A ventilation circuit | Extraction and air intake at the same speed | Separate extraction and air intake | Separate extraction and air intake |
| Current rating allowed for the ventilation (A) | 7 A | 12 A | 8 A | 8 A |
| Adjustable hysteresis | No | Yes | No | No |
| Adjustable negative pressure | No | No | Yes | Yes |
| Price | ¥53,300 | ¥31,900 | ¥30,200 | ¥26,600 |
Manufacturer's values (instructions for the four controllers compared).
Buying guide
Which controller for your extraction system?
Documents & manuals
Twin Controller manual
Setting the target value, the minimum speeds and the negative pressure, connection and safety, in six languages including French.
Document not showing? Some publishers block display inside a frame, so open it in a tab.
Estimate your
delivery time
Your estimate
It covers preparing your order and then the transit time quoted by the carrier, counted in working days.
It is not a guaranteed delivery date: public holidays, peak periods, customs or a carrier delay can extend it. The exact amount, in your currency, is worked out in the cart once your address is entered.
The controller ships in its original box from a distributor's warehouse in France. The exact shipping cost is shown in the basket.
Frequently asked questions
10 questions
6 key questions, 10 in the detailed view
You may also like
Let us talk about your project
A question about this product or your setup? Our team will answer and advise you.
Interest-free instalment payments
Offered depending on the cart amount, at checkout.
Delivery in 2 to 15 working days
Depending on the products and shipping sites. Estimate by destination in the estimator on this page.
After-sales service 7 days a week by email or chat
Our team answers all your questions.
Shop responsibly
Become part of the change.