Pocket conductivity meter for nutrient solution, 0 to 20 mS/cm
This pen measures the electrical conductivity of water, that is, its load of dissolved salts, from 0 to 20 mS/cm to the nearest tenth. Temperature is compensated automatically, calibration is set at one point using the small screwdriver supplied, and 4 button cells give it around 300 hours of battery life.
The summary
- What you receive: the pen and its cap, a calibration screwdriver, the batteries and the instructions.
- What it measures: conductivity from 0.0 to 19.9 mS/cm, in steps of 0.1 mS/cm.
- Compensation: automatic between 5 and 50 °C, based on 2% per degree.
- Calibration: single-point, with a screwdriver, using a 12.88 mS/cm solution.
- In aquaponics: a trend indicator, to be read alongside pH and nitrates from one week to the next.
- Battery life: around 300 hours on 4 x 1.5 V button cells.
Temperature-compensated EC pen, for dosing a nutrient solution or monitoring water
The CD611 is a pocket conductivity meter, a pen-style device that measures the electrical conductivity of water, denoted EC. You remove the cap, immerse the electrodes in the sample and the value appears in millisiemens per centimetre, from 0.0 to 19.9 mS/cm. It is the tool that tells you whether a nutrient solution is too weak, just right or too concentrated, and it is also used to monitor the mineral load of irrigation water or a fish tank. It weighs about 85 g and fits in a pocket, at the edge of the tank.
⚡ What conductivity measures
Pure water conducts electricity very poorly; it is the dissolved ions, from fertilisers, limescale or fish waste, that make it conductive. The more salts a solution contains, the higher its conductivity, so measuring EC gives a direct picture of its nutrient concentration. It does not say which elements are present, but it does say how much there is in total, which is enough to dose a fertiliser or to spot a solution that is running low. The CD611 displays this value in steps of 0.1 mS/cm, a resolution suited to growing solutions, which are managed on differences of a few tenths.
The conductivity of the same solution rises by about 2% per degree of temperature. Without correction, a reading taken in water at 25 °C would appear higher than the same one taken at 15 °C. The CD611 compensates for this effect automatically between 5 and 50 °C and brings the reading back to a reference temperature, which makes your readings comparable from one season to the next.
🪛 Calibrating with a screwdriver
Calibration is done manually, at a single point. You immerse the electrodes in a 12.88 mS/cm calibration solution, then turn the small adjustment screw with the screwdriver supplied until you read the exact value. This setting is held in mechanical memory: it is not lost when the batteries are changed, but it should be checked from time to time, as the electrodes gradually become fouled. The stated accuracy is ±2% of full scale, or about 0.4 mS/cm, which is suitable for managing a nutrient solution.
Rinse the electrodes after each measurement
The salts in a nutrient solution build up on the electrodes and gradually skew the reading. Rinse the tip under tap water after each use, then dry it before putting the cap back on. Only immerse the lower part of the pen in the water: only the electrode area should be submerged.
Reading the pH within the same series of measurements
Conductivity tells you how many salts your solution contains, while pH tells you whether the plants can absorb them. Take both measurements together, at the same moment, to adjust a fertiliser dose. The AMTRA electronic pH tester complements the CD611: one pen for each parameter, and a checking routine that takes a minute.
🐟 Conductivity and aquaponics
In aquaponics, conductivity stays much lower than in hydroponics, since the nutrients come from the fish feed and not from a concentrated fertiliser. Its exact value depends on your source water, the stocking density of fish and the quantity of plants, so the useful figure is above all its trend from one week to the next. A conductivity that keeps rising signals an accumulation of salts that the plants are not absorbing, whereas a prolonged drop signals a system that is becoming depleted. Record the value on a fixed day, alongside the pH and nitrate, and you will build up a history that sheds light on plant deficiencies in aquaponics before they show on the foliage. The guide to getting started with indoor hydroponics shows the other use, dosing a nutrient solution.
Conductivity does not distinguish nitrates from other salts: it complements specific tests without replacing them. Management guides aim for nitrates between 5 and 150 mg/L and total ammonia below 1 mg/L, two values that only a dedicated test will reveal. A stable conductivity does not guarantee that every element is sufficient either: fish feed supplies too little iron, potassium and calcium, hence the additions of DTPA chelated iron, around 2 mg/L every three weeks, and the alternation of calcium hydroxide and potassium hydroxide to raise the pH. These additions show up in your records, after which conductivity returns to its trend.
📋 A measuring routine
Always measure at the same spot and at the same time of day, in flowing water, then record the conductivity along with the pH and the temperature. When starting up an aquaponic system, guides advise a round of tests every day, then a weekly measurement once the system has stabilised, with the pH still needing to be checked more often. A small system loses around 1% of its water per day, through evaporation and plant transpiration: the water goes, the salts stay, and the conductivity rises gradually between top-ups. Top up with water of known conductivity, and measure after each top-up to keep a consistent record.
In hydroponics, the use is the reverse: you prepare a solution from a mineral fertiliser and the CD611 checks that it reaches the value stated on the fertiliser label. If the conductivity falls, the plants are taking up more salts than water; if it rises, they are drinking more than they take up in nutrients, and a top-up of clean water brings it back down. These fertilisers have no place in the fish circuit: they are used in separate hydroponics, in decoupled aquaponics, where the plant section receives a supplement outside the fish tank, or for seedlings in pots. In every case, keep the electrodes clean and check the calibration against the 12.88 mS/cm standard.
Technical specifications
Measuring EC
- Measuring range
- 0.0 to 19.9 mS/cmThat is 0 to 19,900 µS/cm
- Resolution
- 0.1 mS/cm
- Accuracy
- ±2% of full scale
- Compensation
- Automatic, from 5 to 50 °CCoefficient of 2% per degree
- Calibration
- Manual, 1 point, with a screwdriverOn a 12.88 mS/cm calibration solution
- Reference
- Milwaukee CD611
Power supply and size
- Batteries
- 4 x 1.5 V, type LR44Around 300 hours of continuous use
- Dimensions
- Approximately 152 x 30 x 24 mm
- Weight
- Around 85 g
- Use
- Between 0 and 50 °C
Maintenance
- Rinse
- In tap waterAfter each use, to prevent salt deposits
- Storage
- Dry tip, cap back on
To allow for in addition
- Calibration solution
- 12.88 mS/cmTo check and adjust the calibration
- Measuring pH
- 1 pH testerConductivity alone tells you nothing about nutrient uptake
6 further specifications are available in the detailed view.
In the box
- 1 CD611 conductivity meter with protective cap
- 1 calibration screwdriver
- 4 1.5 V batteries
- 1 instruction manual
Manufacturer's values (Milwaukee CD611 datasheet). Aquaponic benchmarks from New Mexico State University and Johns Hopkins University.
Manufacturer and product safety
- Manufacturer
- Milwaukee Instruments
- Website
- www.milwaukeeinst.com
Information provided under Regulation (EU) 2023/988 on general product safety.
The tenth or the hundredth?
Three temperature-compensated pocket conductivity meters, from the pen adjusted with a screwdriver to the 3-in-1 tester with a replaceable probe.
| Range | Resolution | Calibration | Temperature displayed | TDS display | Model | Price | |
|---|---|---|---|---|---|---|---|
| Recommended Pocket conductivity meter for nutrient solution, 0 to 20 mS/cmYour choice | 0 to 19.9 mS/cm | 0.1 mS/cm | Manual, with a screwdriver | No | No | Milwaukee CD611 | ¥4,900 |
| Waterproof conductivity meter, 0.01 resolution, 0 to 20 mS/cmYour choice | 0 to 20.00 mS/cm | 0.01 mS/cm | Automatic, 1 point | Yes | No | Hanna DiST 4 | ¥10,800 |
| Waterproof EC and TDS conductivity meterYour choice | 0 to 20.00 mS/cm | 0.01 mS/cm | Automatic, 1 point | Yes | Yes | Milwaukee EC60 | ¥11,700 |
Ranges, resolutions, calibration and displays based on the Milwaukee and Hanna data sheets and instruction manuals.
Buying guide
Two questions to help you choose your conductivity meter
Estimate your
delivery time
Your estimate
It covers preparing your order and then the transit time quoted by the carrier, counted in working days.
It is not a guaranteed delivery date: public holidays, peak periods, customs or a carrier delay can extend it. The exact amount, in your currency, is worked out in the cart once your address is entered.
The tester is sent in its original box, as a small parcel, from a distributor's warehouse in France. The exact shipping cost is shown in your basket.
Frequently asked questions
8 questions
6 key questions, 8 in the detailed view
You may also like
Let us talk about your project
A question about this product or your setup? Our team will answer and advise you.
Interest-free instalment payments
Offered depending on the cart amount, at checkout.
Delivery in 2 to 15 working days
Depending on the products and shipping sites. Estimate by destination in the estimator on this page.
After-sales service 7 days a week by email or chat
Our team answers all your questions.
Shop responsibly
Become part of the change.