Extraction controller for temperature and negative pressure, 2 outlets
This GSE controller varies the speed of an extractor fan and an air-intake fan according to the temperature read by its 4 m remote probe. It also adjusts the negative pressure, that is, the difference between the air extracted and the air drawn in, in a closed greenhouse, a utility room or a grow room.
The summary
- What you receive: the controller and its temperature probe on a 4 m cable.
- What it controls: an extractor fan and an air intake fan, each on its own output.
- The negative pressure: the air intake runs at 50 to 100% of the extraction speed.
- In aquaponics: it removes heat and humidity from a closed greenhouse without stirring the air at full speed.
- The power: the load of each output is shown on the label; if you cannot check it, allow 2 A, so around 460 W.
- The settings: a set point of 20 to 30 °C, a minimum speed and a negative pressure.
Control of an extractor fan and an air inlet by temperature, with adjustable negative pressure
An extractor fan wired in directly runs at full speed day and night: it over-cools a closed greenhouse in the early morning and does not cool enough in the afternoon. The GSE temperature and negative pressure controller varies its speed according to the temperature measured by a remote probe, placed at crop level. The further the air rises above the setpoint, the faster the fan runs; when the temperature returns towards the chosen value, it slows down to its minimum speed. You thus get an air exchange proportionate to the real needs of your plants.
🌬️ Two outlets, an adjusted negative pressure
The control box runs two devices: the extractor, which expels the hot air, and the intake fan, which brings in fresh air. A dial sets the speed of the latter between 50 and 100 % of that of the former. By removing slightly more air than enters, the installation stays under slight negative pressure: the replacement air arrives through the intended openings, instead of seeping in through the joints, and the flexible walls of a grow tent stay drawn inwards. Another dial lets you set the minimum speed, from 20 to 100 %, to keep a constant air exchange even when the target has been reached.
Setpoint
Extraction speeds up as soon as the air exceeds the chosen temperature, from 20 to 30 °C.
Gradual ramp-up
The speed reaches its maximum 2 °C above the setpoint, without jerks.
Minimum speed
A minimum of 20 to 100% keeps the air moving between two heat peaks.
Probe on a cable
The 4 m cable places the measurement at leaf level, away from the control box.
Checking the load on an outlet
The maximum load of each outlet is printed on the label or in the appliance's manual, because the published values range from 2 A to 600 W depending on the source. Until you have checked it, start from the lowest, 2 A, which is about 460 W at 230 V, and keep a 20% margin; beyond that, you need a contactor. Also check in each extractor's manual that it accepts a variable speed controller, plug the controller into an earthed socket protected by a 30 mA residual current device, and place the box outside the greenhouse, away from water splashes.
🐟 In an aquaponic greenhouse
In a closed greenhouse, the air temperature has a direct effect on the water temperature, and therefore on the three occupants of the system. The guidelines from New Mexico State University put the water of an aquaponic system between 18 and 29 °C, vegetables between 21 and 24 °C and nitrifying bacteria between 25 and 30 °C. They also point out that warmer water holds less dissolved oxygen, whereas fish need at least 5 mg/L. By setting the air target just above the temperature your crops need, you let the controller vent heat as it builds up, before the water in the tanks warms up in turn.
Hang the probe in the shade, in the middle of the crops
If you hang the probe from a small chain in the centre of the greenhouse, at leaf height, it measures the air your plants actually experience. Keep it out of direct sunlight and away from the extraction outlet, the heating and the glass panels, because an exposed sensor reads too high and makes the extractor fan run needlessly. A digital thermometer and hygrometer placed in the same spot lets you check the setpoint within a few days.
💧 Humidity and minimum speed
Fish tanks and plants give off water vapour continuously, so a closed aquaponic greenhouse becomes humid as soon as extraction stops. Relative humidity above 80 or 85% is best avoided in a greenhouse, as it encourages disease and slows plant transpiration. This controller does not measure humidity: it is the minimum speed that maintains a background rate of air exchange, even on cool days when the temperature setpoint is never reached. In the evening and at daybreak, when relative humidity peaks, this background flow rate stops condensation from running down the walls and dripping onto the leaves.
Adjustment is done by observation. Start with a moderate minimum speed, measure the humidity at leaf height for a few days with a hygrometer, then raise this minimum if condensation persists in the morning, or lower it if the greenhouse gets too cold at night. If condensation remains a problem despite this, the GSE controller with humidity sensor, which also speeds up extraction when the air becomes too humid, or a compressor dehumidifier can take over. The guide to looking after your aquaponic system in summer explains how to manage heat during the hottest months.
🎚️ Setpoint and speed ramp-up
The speed ramp is fixed at the factory: the speed starts from the minimum you have set at the setpoint and reaches its maximum 2 °C above, which gives a clear response without sudden jolts. So set the setpoint 1 to 2 °C below the temperature you do not want to see exceeded. Greenhouse controllers commonly work with differentials of 1 to 4.5 °C, and this one sits at the lower end of that range, as close as possible to the setpoint. Finally, choose the setpoint according to the most demanding crop in the greenhouse, since all the beds share the same air, bearing in mind that it can be set from about 20 to 30 °C.
The negative pressure is then adjusted by eye. Start with the air intake well below the extraction speed, then increase it until you see the flexible walls of a grow tent stay slightly sucked in without pressing against the frame. In a utility room that houses the pumps, the filter and the sump tank of an aquaponic system, the same negative pressure stops humid air from spreading through the house, since air always flows from the neighbouring room towards the utility room, then outside.
🔧 Fitting and checking the probe
The unit is fixed to a non-flammable wall, with 20 cm of clear air around it, out of reach of splashes, and the probe reaches the crops via its 4 m cable, which can be extended up to 50 m if you prefer to keep the unit in a neighbouring room. Dust that settles on a sensor gradually skews its readings: blow it off regularly. Once a year, check the accuracy of the probe by comparing it with a reference thermometer placed in a glass of water and crushed ice, which should read 0 °C. Note any discrepancy and adjust the set point by the same amount, since the stated accuracy of the probe is ±0.5 °C.
⚡ Connecting and protecting the circuit
Speed is controlled by chopping the voltage with a triac, so only AC motors declared compatible with a speed controller are suitable. An extractor fan with an EC electronic motor takes its setpoint from a separate control wire and cannot be driven this way, nor can a fan with two switched speeds. At start-up, a motor briefly draws more than its running current: on the cautious basis of 2 A per output and with a 20% margin, aim for motors of 1.6 A at most, or roughly 370 W, unless the label states more. The triac gives off heat, which is why it must be mounted on a concrete or brick wall, never on wood, with 20 cm of clearance. If it overheats, two internal sensors cut the unit off at around 75 °C: unplug it, ventilate its location, then plug it back in. A 30 mA residual current device must protect the circuit, and the probe, powered at extra-low voltage, can be placed in the humid air of the greenhouse while the housing stays dry.
Technical specifications
Regulation
- Parameters
- Temperature, negative pressure
- Negative pressure
- Air inlet at 50 to 100 % of the extraction
- Minimum speed
- Off or 20 to 100 %
- Probe
- 4 m cableExtendable up to 50 m
- Setpoint
- Around 20 to 30 °C
- Ramping up speed
- Maximum of +2 °C
The device
- Outlets
- 2, one for the extractor fan, one for the air intakeLoad on the label, 2 A without checking, 20% margin
- Probe accuracy
- ±0.5 °C
- Dimensions
- 16 x 10 x 9 cm
- Weight
- 0.8 kg
- Protection
- IP44Water splashes, no run-off
- Fitting
- Non-flammable wall, 20 cm of air
Greenhouse guidelines
- Humidity to avoid
- Above 80 to 85%
- Probe position
- At leaf height, in the shade
To allow for in addition
- Ventilation
- An extractor fan and an air inlet
- Control
- Thermometer and hygrometer
8 further specifications are available in the detailed view.
In the box
- 1 GSE temperature and negative pressure controller
- 1 temperature probe on a 4 m cable
Manufacturer's values (instructions) and those of the brand's resellers. Water benchmarks from New Mexico State University, humidity from Rutgers University.
Manufacturer and product safety
- Manufacturer
- GSE
Information provided under Regulation (EU) 2023/988 on general product safety.
Which controller for your extraction?
Three two-outlet controllers, with dials or learned speed.
| Measures humidity | Temperature only | How to adjust the speed | Probe length (m) | Load per outlet | Display | Price | |
|---|---|---|---|---|---|---|---|
| Extraction controller for temperature, humidity and negative pressureYour choice | Yes | No | Dials for minimum speed and negative pressure | 4 m | On the label, 2 A by default | Indicator lights | ¥30,200 |
| Recommended Extraction controller for temperature and negative pressure, 2 outletsYour choice | No | Yes | Dials for minimum speed and negative pressure | 4 m | On the label, 2 A by default | Indicator lights | ¥20,500 |
| Learning-speed extraction controller, 2 x 7 AYour choice | No | Yes | Speed learned, then stabilised | 2 m | 7 A | Digital display | ¥24,800 |
Manufacturers' values (instructions and data sheets for the three controllers).
Buying guide
Which controller for your extraction system?
Documents & manuals
GSE controller manual
Installation, setting the set point, the minimum speed and the negative pressure, safety, in eighteen languages including French.
Document not showing? Some publishers block display inside a frame, so open it in a tab.
Estimate your
delivery time
Your estimate
It covers preparing your order and then the transit time quoted by the carrier, counted in working days.
It is not a guaranteed delivery date: public holidays, peak periods, customs or a carrier delay can extend it. The exact amount, in your currency, is worked out in the cart once your address is entered.
The controller ships in its original box from a distributor's warehouse in France. The exact shipping cost is shown in the basket.
Frequently asked questions
10 questions
6 key questions, 10 in the detailed view
You may also like
Let us talk about your project
A question about this product or your setup? Our team will answer and advise you.
Interest-free instalment payments
Offered depending on the cart amount, at checkout.
Delivery in 2 to 15 working days
Depending on the products and shipping sites. Estimate by destination in the estimator on this page.
After-sales service 7 days a week by email or chat
Our team answers all your questions.
Shop responsibly
Become part of the change.