pH and EC calibration solution and probe maintenance

Regular price $9.00
Regular price Sale price $9.00

These 300 ml bottles keep your pH meter and conductivity meter accurate: pH 4.00 and 7.00 buffers for two-point calibration, conductivity standards at 1.413 and 2.76 mS/cm, and storage and cleaning solutions for the probe.

Ref. GT-PH7·Dosing and measuring
Solution : Tampon ph 7
Customer support 7 days a week by email
Delivery within 2 to 15 business days
100 % secure payment
Visa Mastercard American Express PayPalCartes Bancaires Apple Pay Shop Pay Bancontact EPS KlarnaMobilePaySatispay

The summary

  • Capacity: a 300 ml bottle of the solution you choose, from the six in the range.
  • For pH: the 7.00 buffer corrects the probe's offset, the 4.00 buffer corrects its slope.
  • Conductivity meter: 1.413 mS/cm for low-nutrient water, 2.76 mS/cm for nutrient solutions.
  • For the probe: a potassium chloride solution that keeps it moist, an acid cleaner that cleans it overnight.
  • How often: a monthly conductivity check, and a pH calibration whenever the reading is going to be used to correct the water.
  • Fish water: a pH range of 6 to 7, where an error of a few tenths is enough to throw a correction off.

pH 4 and 7 buffer solutions, conductivity standards and probe care, in 300 ml bottles

These 300 ml Growth Technology solutions calibrate and maintain a pH meter or a conductivity meter: pH 4.00 and 7.00 buffers for a two-point calibration, 1.413 and 2.76 mS/cm standards, and probe storage and cleaning. For the water of an aquaponic system, the 1.413 mS/cm standard is the closest to the measured values.

A pH meter or an electronic conductivity meter is only accurate for as long as it has been calibrated recently. Its probe ages, becomes coated with deposits and its response gradually drifts away from the true values, so a meter that has never been checked can display a wrong figure without the slightest warning sign. These six 300 ml solutions cover the three tasks that keep your meter reliable: pH calibration, conductivity checking and probe maintenance. You choose the bottle you need, or several to equip a new meter in one go.

🎯 pH calibrated at two points

A pH probe produces a small electrical voltage that varies with the acidity of the water, and the meter converts this voltage into a pH value. Calibration teaches it the exact correspondence specific to your probe, which changes with its age and how clean it is. The pH 7.00 buffer first sets the neutral point, that is the probe's offset, then the pH 4.00 buffer sets its slope, in other words the voltage difference between two pH units. Calibrating at pH 7 alone is enough for a quick check, but it leaves the slope as it is, and the error grows as the measured value moves further from 7. With both buffers, you cover the whole range that matters in cultivation, between 5 and 7.

The procedure itself takes a few minutes. Rinse the probe with water, pour a little pH 7 buffer into a clean cup, immerse the tip and confirm the value following your device's instructions. Rinse again, then repeat with the pH 4 buffer. The solution used is then thrown away, because once it has been in contact with the probe it can no longer be relied upon, and pouring it back into the bottle would contaminate everything else. For soilless growing, the range recommended by the manufacturer is between 5.8 and 6.2 for most plants, and around 5.5 on rockwool: this is precisely the zone that the two buffers bracket.

⚡ Two conductivity standards

Electrical conductivity, abbreviated EC, reflects the amount of salts dissolved in the water, since the more ions a solution contains, the better it conducts current. It therefore measures the strength of a nutrient solution, or the mineral load of irrigation water. The 1.413 mS/cm calibration solution suits low-mineral water, such as tap water or the water of an aquaponic system, while the 2.76 mS/cm solution comes closer to hydroponic nutrient solutions in full production. Choose the one whose value is closest to what you usually measure, because a meter is most accurate around its calibration point.

The manufacturer recommends checking your conductivity meter once a month: dip the probe into a little calibration solution, and the display should show its value. If it doesn't, adjust it following its instructions, whether you already own one or choose one from our electronic testers.

A single tester for pH and conductivity

If you monitor both the pH and the conductivity of your water, the ARKA myAqua pH, EC and TDS pocket tester measures both with a single device. Its conductivity is calibrated at 1,413 µS/cm, exactly the value of the low standard in this range, which means you can check it every month without buying its original bottle again. That way you keep readings that are comparable from one week to the next, for both the acidity and the mineral load of the water.

🌱 Measuring accurately in aquaponics

In your aquaponic system, the pH is a compromise between the fish, the nitrifying bacteria in the filter and the plants, and the target range is between 6 and 7, above the range aimed for in soilless growing. Nitrification releases hydrogen ions continuously, so the water gradually acidifies, at a rate that depends on its carbonate reserve. As you correct the pH in small doses, a discrepancy of a few tenths in the reading translates directly into a poorly dosed correction. Conductivity, for its part, stays lower than in hydroponics, since the nutrients come from the fish feed, so the 1.413 mS/cm calibration solution is the one you will use. The article on pH regulation in aquaponics details the possible corrections once the measurement is reliable.

🧴 Storing and cleaning the probe

The glass bulb of your pH probe must be kept clean and, for most models, permanently moist: once dry, it responds slowly and loses accuracy. The storage solution, based on potassium chloride, is there first and foremost for this purpose. After each reading, you rinse the tip with water, then pour about 2 cm of solution into the cap or into a small container, so that the probe stands upright and submerged in it. A probe should never be stored in pure water, and the solution in the cap should be renewed every 7 to 14 days. With some instrument manufacturers, such as Bluelab, poor probe maintenance can even void the warranty.

The same solution can also be used to refill liquid-electrolyte probes, those whose body has a filling hole: you top up the level regularly following your device's instructions, which ensures consistent readings. It is not suitable, however, for gel electrodes, which cannot be refilled. When the reading becomes slow or unstable despite a recent calibration, the probe is usually fouled: leave it to soak overnight in the cleaning solution, which dissolves the salts, debris and dirt accumulated during use, then rinse it and calibrate it again.

The cleaning solution is a diluted acid

The cleaning solution contains dilute hydrochloric acid. Handle it with gloves, keep it away from your eyes, and rinse any splashes on the skin thoroughly with water. After soaking, rinse the probe before putting it back in the storage solution, then carry out a full calibration again before the next measurement.

🧭 The mistakes that skew the reading

Pouring the solution back

A solution that has had a probe in it is contaminated. Poured back into the bottle, it skews all subsequent calibrations.

Skip the rinse

Drops of pH 7 buffer left on the probe will skew the pH 4 buffer reading. Rinsing with water removes them.

Leave the probe dry

A dry glass bulb responds slowly. The cap filled with storage solution avoids this fault.

Calibrating a dirty probe

Calibrating on a fouled probe records the error. Cleaning comes first, then calibration.

📦 Which bottle for which device

For a pH meter, you need at least the two buffers, pH 7 and pH 4, and the storage solution, which protects the probe between sessions; the cleaning solution completes the kit as soon as the probe becomes sluggish. For a conductivity meter, a single standard is enough, the one whose value is closest to your usual readings. A combined tester, which measures both pH and conductivity, therefore needs four bottles, and five with the cleaning solution. Each 300 ml bottle lasts a long time, since you only pour out a small amount for each check. It keeps best with the cap on, in a cool place and away from light, which preserves its value between uses.

Technical specifications

Calibration

pH 7 buffer solution
pH 7.00Sets the neutral point, the first buffer of the calibration
pH 4 buffer solution
pH 4.00Sets the probe's slope, after the pH 7 buffer
Low EC standard
1.413 mS/cm, or 1,413 µS/cmFor tap water and aquaponic systems
High EC standard
2.76 mS/cmFor hydroponics nutrient solutions

Probe maintenance

Storage
Potassium chloride solutionKeeps the glass bulb moist between measurements
Probe filling solution
Liquid electrolyte probesNot suitable for gel electrodes
Cleaning
Diluted hydrochloric acidDissolves salts and deposits with an overnight soak
Cap replacement
Every 7 to 14 daysA probe should never be stored in pure water

Use

Capacity
300 ml per bottle
pH calibration order
pH 7, then pH 4Rinsing the probe between the two buffer solutions
Checking conductivity
Once a monthThe display must show the value of the standard
Solution used
Discarded after each useA solution poured back into the bottle contaminates everything else
Storing the bottle
Sealed, in a cool place, away from light
Manufacturer
Growth Technology, Taunton, United Kingdom

To allow for in addition

Measuring device
1 pH meter or conductivity meterCan be calibrated against the values of these solutions
Container
1 small clean cupTo pour out the amount needed without dipping the probe into the bottle

8 further specifications are available in the detailed view.

In the box

  • 1 300 ml bottle of the chosen solution

Values, uses and checking frequency based on the manufacturer's website, compositions and directions for use from retailer listings in the United Kingdom and Australia. pH range in aquaponics based on the FAO manual on small-scale aquaponics.

Manufacturer and product safety

Manufacturer
Growth Technology Ltd.
Postal address
Great Western Way, Taunton, Somerset TA2 6BX, Royaume-Uni

Information provided under Regulation (EU) 2023/988 on general product safety.

Estimate your
delivery time

The bottles are dispatched from a distributor's warehouse in France, in a small, well-padded parcel. The exact delivery charge is shown in your basket.

Frequently asked questions

6 questions

6 key questions

You may also like

Let us talk about your project

A question about this product or your setup? Our team will answer and advise you.

Interest-free instalment payments

Offered depending on the cart amount, at checkout.

Delivery in 2 to 15 working days

Depending on the products and shipping sites. Estimate by destination in the estimator on this page.

After-sales service 7 days a week by email or chat

Our team answers all your questions.

Shop responsibly

Become part of the change.