All-in-one climate controller for lamps, air and humidity
The Cli-mate Total Controller brings together in a single unit the control of four 600 W lights, ventilation speed up to 7 A, a heater up to 2,400 W and a humidifier or dehumidifier. Its dual temperature and humidity sensor keeps the climate under control in a growing room or a lit seedling room.
The summary
- What you receive: a Cli-mate controller, its dual temperature and humidity probe and a spare fuse.
- What it controls: 4 lights of 600 W, ventilation up to 7 A, a 2,400 W heater and humidity.
- The total load: what the wall socket can take, 16 A at most, with a 20% margin and a 30 mA residual current device.
- The two setpoints: a daytime temperature for the air, a night-time temperature for the heating.
- Which room: a lit grow room, a seedling room or an indoor greenhouse.
- In aquaponics: the lit nursery where the system's plants are prepared.
Lighting, ventilation, heating and humidity of a grow room, all controlled from a single unit
A lit growing room soon calls for a whole tangle of control boxes: a timer for the lamps, a controller for the extractor fan, a thermostat for the heating, a humidistat for humidity. The Cli-mate Total Controller brings these functions together in a wall-mounted box measuring 25 x 22 x 12 cm, adjusted by dials on the front, and runs everything from the same temperature and humidity probes. You can thus set the light, air, heat and humidity of a seedling room or a growing room from a single place.
🎛️ Four functions in one unit
The lighting
Four sockets of 600 W each, switched on and off together by the built-in timer, to the nearest quarter of an hour.
Ventilation
The fans vary their speed according to the daytime temperature, between a set minimum and maximum, up to 7 A.
The heating
A dedicated socket takes a heater of up to 2,400 W, switched on below the night-time setpoint.
Humidity
A humidifier or dehumidifier switches on at the chosen level, with a 5 % margin.
Ventilation is the heart of the unit. You set the daytime temperature you want, between 5 and 55 °C, then the minimum speed of the fans, so that the air never stops circulating, and their maximum speed, which caps the noise and the draughts. Above the setpoint, the speed rises gradually from the minimum towards the maximum, without sudden steps, so the motors do not alternate between stopping and full power. The dials adjust in steps of 1 °C for temperature and 5% for humidity, which is enough to set a target to within a degree.
A three-position selector controls ventilation: on according to your settings, off, or full power to ventilate all at once after watering or an intervention. Several fans can share the ventilation output, an extractor and an air intake fan for example, provided their combined current stays below 7 A; they then run at the same speed. The temperature probe goes in the centre of the growing space, at plant height and shaded from the lamps, where the reading truly represents the air your crops breathe.
Add up everything that runs together
Each socket has its own limit: 600 W per lamp, 7 A for ventilation, 2,400 W for heating, 1,600 W for the dehumidifier and 700 W for the humidifier. These limits cannot simply be added together, because everything runs through the controller's wall socket: a domestic 16 A socket allows 3,680 W, and a 20% margin brings the total down to about 2,900 W with everything running at once. Connect the controller on its own to an earthed wall socket, on a circuit protected by a 30 mA residual current device, and never to an extension lead.
A thermo-hygrometer with memory to check conditions overnight
Setpoints are adjusted during the day, whereas the deviations happen at night, with the lights off, when the room cools down and humidity rises. The digital greenhouse thermo-hygrometer placed next to the probes records the minimums and maximums. That way, over the first few mornings, you can check that the heating held the temperature and that humidity stayed within your range, then correct one dial at a time.
This limit of around 2,900 W shapes which equipment you can choose. Four 600 W lamps already draw 2,400 W, which leaves about 500 W for fans and humidity control, and rules out running a 1,600 W heater at the same time as the lighting. In practice, the heater works mostly at night, with the lamps off, and LED panels of a few hundred watts free up a wide margin. For a seedling room lit by two LED panels, you therefore keep room for a heater, two extractor fans and a humidifier without coming close to the limit.
💡 Programming the light
The built-in timer switches the four lighting sockets on and off together, at the time you choose, which removes one more box from the power strip. Each pin pushed in on its 24-hour dial corresponds to 15 minutes of lighting. For seedlings and young plants, 14 to 16 hours of light per day is suitable, with fluorescent tubes placed 10 or 15 cm above the trays and raised as the plants grow. A fixed duration, kept every day without fail, gives more even plants than lighting switched on by hand.
The lighting warms the room during the day, and it is then the ventilation that does the work; at night, with the lamps off, the temperature drops and the heating takes over. The controller manages both phases with the same probe, which stops a separate thermostat heating while an extraction regulator is cooling. Set the heating setpoint a few degrees below the ventilation setpoint to leave a neutral band between the two.
🌱 A nursery for the aquaponic greenhouse
In aquaponics, young plants are often started outside the system, in a nursery, before joining the grow beds or rafts. Sow into rockwool cubes, coconut fibre or germination sponges, then wait at least 2 weeks after the first true leaves appear before transplanting. The Total Controller looks after the conditions in this lit growing chamber by itself through the winter: sixteen hours of light, a stable night-time temperature thanks to the heating, and humidity kept under control when the trays transpire.
The recommendations vary according to what you are sowing. Lettuces germinate and grow best between 15 and 20 °C, and above 25 °C their seeds can go dormant and fail to sprout. Fruiting vegetables such as tomato or pepper prefer a warmer room, around 21 to 24 °C. So set the controller's temperature to suit the crop of the moment, and if possible separate the lettuces from the fruiting vegetables into two successive sowing cycles. The guide to succeeding with spring seedlings in aquaponics gives their calendar.
💧 Humidity and heating
The humidity outlet controls a humidifier or a dehumidifier according to the level you choose, from 20 to 100 %, with a 5 % band around the setpoint that prevents constant restarts: the humidifier can draw 700 W and the dehumidifier 1,600 W. Seedlings under a lid appreciate humid air for the first few days, then the young plants need drier, refreshed air to avoid damping off and grey mould, which spreads above 85 % relative humidity. In a room that also houses a small aquaponic system, the water evaporating from the fish tank raises the humidity of the air, and the dehumidifier driven by the controller brings it back below your setpoint.
The heating socket accepts a heater of up to 2,400 W, switched on when the temperature falls below the night-time setpoint, that is, the lowest temperature you are willing to tolerate with the lights off. This heater acts on the air, not on the water: if you keep fish in the same room, their temperature is controlled by a heater submerged in the tank, with its own thermostat, such as a glass thermostatic heater. Vegetables grow best between 21 and 24 °C, whereas tilapia need 27 to 29 °C, which is why the water and the air have to be regulated separately.
🔧 Getting started
Plug in the fans first, then set their minimum speed, which ensures they never stop completely. Next, set the target temperature, the maximum speed and the hysteresis, before programming the lamps' time window. Finish with the humidity level and connecting the humidifier or dehumidifier. The fans must accept speed variation: a device with an electronic motor driven by its own controller is not suitable. Observe a full day and night before adjusting any setting again.
The box contains the wired controller, its dual temperature and humidity probe and a spare fuse. Lights, fans, heating and the humidifier or dehumidifier then plug into their respective sockets, each marked on the front. The unit, protected to IP44 against splashing, mounts on the wall outside the space it regulates, away from watering and the heat of the lamps, within easy reach so you can keep track of your settings as the seedlings develop.
⚡ Plugging in safely
Each type of appliance loads the sockets in its own way. A heater is a resistive load: it draws the current shown on its rating plate as soon as it is switched on. A fan motor and a discharge-lamp ballast draw a much higher current at start-up than when running steadily, and an LED power supply does the same for a fraction of a second, while it charges its capacitors. So keep about 20% of headroom below each limit, and connect to the ventilation outlet only AC motors whose speed is regulated by voltage, never an EC-motor fan driven by its own controller. The housing, rated IP44, withstands water splashes from every direction, but not running water or immersion: mount it in a dry spot, with the cables hanging down in a loop beneath it so that a drip cannot travel up to the terminals. The circuit supplying it must be protected by a 30 mA residual-current device, like all circuits in a dwelling under standard NF C 15-100. The manufacturer declares the appliance compliant with the European Low Voltage and Electromagnetic Compatibility directives, and guarantees it for 12 months after installation.
Technical specifications
The outlets
- Lighting
- 4 x 600 W, built-in timer
- Ventilation
- Variable speed, 7 A in totalOne or more AC motor fans
- Heating
- Heater up to 2,400 WActive below the night-time setpoint
- Humidity
- Humidifier 700 W, dehumidifier 1,600 W
- Total load
- The wall socket's rating, 16 A at mostApproximately 2,900 W with a 20% margin, all appliances combined
- Control
- Selector: on, off, 100%
Regulation
- Temperature
- 5 to 55 °C
- Humidity
- 20 to 100% RH
- Adjustment settings
- 1 °C and 5 % humidity5 % margin around the humidity setpoint
- Clock
- 15-minute jumpersOn a 24-hour dial
The device
- Feeding
- 220 to 240 V, 50 Hz, 1.30 m cable
- Protection
- IP44Water splashes, no run-off
- Dimensions
- 25 x 22 x 12 cm
- Weight
- 1.2 kg
- Warranty
- 12 months after installation
- Compliance
- Low Voltage and EMC Directives
To allow for in addition
- Fans
- Extractor fan and air inlet with variable speed
- Checking the settings
- Greenhouse thermo-hygrometer
- Electrical circuit
- Earthed socket, 30 mA RCD
- Night-time heating
- Heater of 2,400 W at most
12 further specifications are available in the detailed view.
In the box
- 1 wired Cli-mate Total Controller
- 1 dual temperature and humidity probe
- 1 spare fuse
Manufacturer's values (instructions and datasheet). Seedling guidelines based on Iowa State University and the FAO.
Manufacturer and product safety
- Manufacturer
- Cli-mate
Information provided under Regulation (EU) 2023/988 on general product safety.
Which controller for your whole room?
Four controllers from the same manufacturer, from simple extraction control to managing the whole room.
| Recommended All-in-one climate controller for lamps, air and humidityYour choice | Extraction controller with adjustable hysteresis, 12 AYour choice | Temperature and humidity ventilation controller, 2 x 4 AYour choice | Temperature-based extraction controller, 2 outlets of 4 AYour choice | |
|---|---|---|---|---|
| What it measures | ||||
| Temperature only | No | Yes | No | Yes |
| Measures humidity | Yes | No | Yes | No |
| Controls humidity through ventilation | No | No | Yes | No |
| What it controls | ||||
| Controls the lighting | Yes | No | No | No |
| Heater socket | Yes | No | No | No |
| Air control | A ventilation circuit | Extraction and air intake at the same speed | Separate extraction and air intake | Separate extraction and air intake |
| Current rating allowed for the ventilation (A) | 7 A | 12 A | 8 A | 8 A |
| Adjustable hysteresis | No | Yes | No | No |
| Adjustable negative pressure | No | No | Yes | Yes |
| Price | $505.00 | $302.00 | $286.00 | $252.00 |
Manufacturer's values, taken from the instruction manuals of the four controllers.
Buying guide
Which one will cope with the climate in your room?
Documents & manuals
Total Controller manual
Settings, wiring diagram and safety instructions, in six languages including French.
Document not showing? Some publishers block display inside a frame, so open it in a tab.
Estimate your
delivery time
Your estimate
It covers preparing your order and then the transit time quoted by the carrier, counted in working days.
It is not a guaranteed delivery date: public holidays, peak periods, customs or a carrier delay can extend it. The exact amount, in your currency, is worked out in the cart once your address is entered.
The controller ships in its original box from a distributor's warehouse in France. The exact shipping cost is shown in the basket.
Frequently asked questions
12 questions
6 key questions, 12 in the detailed view
You may also like
Let us talk about your project
A question about this product or your setup? Our team will answer and advise you.
Interest-free instalment payments
Offered depending on the cart amount, at checkout.
Delivery in 2 to 15 working days
Depending on the products and shipping sites. Estimate by destination in the estimator on this page.
After-sales service 7 days a week by email or chat
Our team answers all your questions.
Shop responsibly
Become part of the change.