Digital pocket EC and TDS conductivity tester
This AMTRA tester measures the water's conductivity (EC) and TDS in a few seconds, from 0 to 9,990 µS/cm or ppm, with automatic temperature compensation.
It shows the total amount of dissolved salts, and therefore how rich your solution is in nutrients.
The summary
- Three values: EC and TDS from 0 to 9990, and temperature.
- Uses: adjusting a nutrient solution and monitoring the water of a system.
- Calibration: single-point, with a 1,413 µS/cm solution.
- What is supplied: the tester, its rigid case and its battery.
Pocket conductivity meter that measures EC, TDS and water temperature
Pure water barely conducts electricity. As soon as it contains dissolved salts (calcium, magnesium, nitrate, potassium or phosphate), the more of them it holds, the better it conducts. Electrical conductivity, or EC, measures this: it does not tell you which salts are present, but it does tell you how much there is in total. It is the simplest way to find out whether your nutrient solution is too weak, about right or too strong, and this tester gives you the reading in a few seconds, with the electrode dipped in the water.
📏 EC and TDS, one and the same measurement
The meter shows two values. EC, in microsiemens per centimetre (µS/cm), is the actual measurement. TDS, in ppm, is a conversion of it: the meter estimates the mass of dissolved salts from the conductivity, using a fixed factor. As this factor varies from one brand to another, most often 0.5 or 0.7, always compare like with like, and preferably EC, which does not depend on any convention. Bear in mind too that 1 mS/cm equals 1,000 µS/cm: a fertiliser label that targets an EC of 1.2 corresponds to 1,200 on this display. Both are shown from 0 to 9990, and you switch between them with a single press of the SHIFT button.
Conductivity rises with temperature, by about 2% per degree. The tester has built-in automatic temperature compensation (ATC): it corrects the reading to a reference value, so water at 18 °C and the same water at 26 °C give the same result. It also shows the water temperature, in degrees Celsius or Fahrenheit, from 0.1 to 80 °C. A HOLD button freezes the value so that you can read it out of the water, and the meter switches itself off after 5 minutes without use.
🧪 Taking an accurate measurement
Rinse the electrode in clean water, dip it a few centimetres into the sample, stir gently to dislodge any bubbles, then wait for the reading to settle. Rinse again after each measurement, especially between a concentrated nutrient solution and soft water. Take a hydroponic solution made up for lettuces: if the tester reads 1,600 µS/cm when you are aiming for around 1,200, add clean water a little at a time until you are back within the target range.
Measuring pH at the same time as EC
EC tells you how many nutrients the water contains, pH tells you whether they remain available to the roots, and neither value can be corrected without looking at the other. The AMTRA electronic pH tester is used in the same way as this EC meter, with the electrode dipped in the sample, and it too compensates for the water temperature. With both meters, a full check of your nutrient solution takes just a few minutes.
A few benchmarks help you interpret the readings. Good-quality reverse osmosis water reads below 20 µS/cm, soft tap water a few hundred, and very hard water often more than 600. In a balanced aquaponic system, conductivity generally sits between a few hundred and just over 1,000 µS/cm, while a hydroponic solution for lettuces often runs between 1,000 and 1,800 µS/cm depending on the fertiliser, and one for tomatoes noticeably higher. These figures vary with the fertiliser and the source water: the most useful approach is to compare your own readings over time, using the same meter. The guide to maintaining a hydroponic tower fits this reading into the weekly routine.
Hydroponics
The tester is used to set the concentration of the nutrient solution each time you prepare it.
Aquaponics
The measurement tracks the build-up of nutrients over the weeks.
RO water
A reading close to zero confirms that the membrane is holding back the salts well.
Tap water
A single reading reveals its mineral content before you use it.
🌱 In aquaponics
In an aquaponic system, the nutrients come from the fish feed, and their concentration changes slowly. EC lets you follow this change without endless chemical tests: a value that stays very low points to a system that is still lean, while a value that climbs week after week shows that salts are building up and that a partial water change is due. Always measure at the same point in the circuit, once a week at the same time as the pH, and record the values in a notebook. Source water that is already above 1,500 µS/cm is poorly suited to aquaponics, as it leaves little room for nutrients. The guide to getting an aquaponic system off to a good start explains which readings to track during the first few weeks.
🔧 Calibration and maintenance
The tester comes calibrated and can be recalibrated at one point, using a 1,413 µS/cm calibration solution sold separately, such as the 1.413 mS/cm standard in the calibration and probe care solutions, with a few presses of its SHIFT and HOLD buttons. Repeat this calibration after a long period without use, after heavy use, or whenever you need high accuracy, for example before making up a nutrient solution for seedlings. If the electrode has dried out, soak it for a few hours in reverse osmosis water before measuring, otherwise the first readings will remain unstable.
The display resolution adapts to the measured value: it counts up 1 by 1 to 1,000, then 10 by 10 beyond that. Reverse osmosis water can therefore be read to the nearest unit, while a nutrient solution at 1,200 µS/cm is read to the nearest 10, which is enough to decide on a dilution. After use, rinse the electrode in clean water, shake it, then put its cap back on before storing the meter in its case. The automatic shut-off after 5 minutes saves the battery if you forget to switch the tester off.
Technical specifications
Measurements
- Conductivity (EC)
- 0 to 9990 µS/cm
- TDS
- 0 to 9990 ppm
- Temperature
- 0.1 to 80 °C, display in °C or °F
- Temperature compensation
- Automatic (ATC)
- Functions
- HOLD, EC and TDS toggle, automatic shut-off after 5 minutes
- Dimensions and weight
- 15.2 × 2.8 × 0.9 cm, 55 g
To allow for in addition
- Calibration
- 1,413 µS/cm calibration solution
- Measuring pH
- Electronic pH meter
In the box
- 1 digital EC and TDS tester
- 1 rigid storage case
- 1 3 V battery
- 1 instruction leaflet in French
Manufacturer's values (description and instructions for use, item A3076618). 24-month guarantee.
Manufacturer and product safety
- Manufacturer
- CAMON&CROCI Pet Group S.p.A.
- Postal address
- Corso Italia 22, 20122 Milano (MI), Italie (siège légal) ; site opérationnel : Via S. Alessandro 8, 21040 Castronno (VA), Italie
- Contact
- info@croci.net
- Website
- www.amtra.net
Information provided under Regulation (EU) 2023/988 on general product safety.
Estimate your
delivery time
Your estimate
It covers preparing your order and then the transit time quoted by the carrier, counted in working days.
It is not a guaranteed delivery date: public holidays, peak periods, customs or a carrier delay can extend it. The exact amount, in your currency, is worked out in the cart once your address is entered.
Delivered to your home by Colissimo or Chronopost, as you prefer at checkout. The exact cost is shown in the basket, according to the total weight of your order.
Frequently asked questions
8 questions
6 key questions, 8 in the detailed view
You may also like
Let us talk about your project
A question about this product or your setup? Our team will answer and advise you.
Interest-free instalment payments
Offered depending on the cart amount, at checkout.
Delivery in 2 to 15 working days
Depending on the products and shipping sites. Estimate by destination in the estimator on this page.
After-sales service 7 days a week by email or chat
Our team answers all your questions.
Shop responsibly
Become part of the change.